Details.

Power on

Failed.

ator_82713|INF| 51|2022-03-28 16:15:37.623091| MAIN > Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR - GENERIC_SYS_ERROR
WfsArbitrator _82713|ERR| 52|2022-03-28 16:15:37.623176| MAIN > Exception: Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR
WfsArbitrator _82713|ERR| 53|2022-03-28 16:15:37.623247| MAIN > Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR (-1000) GENERIC_SYS_ERROR

SECOND TRY.

ok

Set flat

Test preset.

Mon Mar 28 17:28:30.202 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[162] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 28

2022-03-28 17:27:40.854924| MAIN > Maximum mode index used to apply flat -># 635

home the hexapod.

Authorize luci.

No light in the CCD47

Check light path. No Luci cal unit.

Ok.

GCS probe not parked.

homed

Restarted the whight source process.

Light in the CCD47.

Acquire ref.

center pupil

camera no live during the close loop.

MasterDiagnostic _82619|WAR| 14334|2022-03-28 18:20:01.955578| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 883 (instead of packetId 0 for frameId 883)
MasterDiagnostic_82619|WAR| 14335|2022-03-28 18:20:01.955592| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_82619|WAR| 14336|2022-03-28 18:20:01.955634| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 883 (instead of packetId 0 for frameId 883)
MasterDiagnostic_82619|WAR| 14337|2022-03-28 18:20:01.955664| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_82619|WAR| 14338|2022-03-28 18:20:01.963921| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 886 (instead of packetId 5 for frameId 884)
MasterDiagnostic_82619|WAR| 14339|2022-03-28 18:20:01.963961| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_82619|WAR| 14340|2022-03-28 18:20:01.964037| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 886 (instead of packetId 0 for frameId 886)
MasterDiagnostic_82619|WAR| 14341|2022-03-28 18:20:01.964054| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_82619|WAR| 14342|2022-03-28 18:20:01.964096| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 886 (instead of packetId 0 for frameId 886)
MasterDiagnostic_82619|WAR| 14343|2022-03-28 18:20:01.964108| BCU39 > FramesDownloader BCU39: packet successfully ignored !

wfs masterdiagnostic powercycleprocess.

BCU2K power cycle.

Restart 1x1 crop binning.

set gain. zero in Adsec.

WFS set:

bin 1

freq=200,mod=3l/d

emgain=400

close loop from WFS.

OK. OCAm live.

apply gain: 0.1modi10

camera lens converged posiytion @341 rot

x=30.81,y=54

bin 1 rotation check.

start 11:32

there is a shift of 10 lixels in X positive. This is still in the amplitude rotation.

bin1_20220328.png

bin2 rotation check.

Still in range, penty movements. No shift required.

bin2_20220328.png

bin3 rotation check

Still in range, the Y xis minimum goe to -81, x axis min=-51, ymax=55, xmax=74

No shift required.

bin4 rotation check.

Mon Mar 28 19:36:26.832 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[173] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.51,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)--

bin4-20220328_ocam.png

observed jump, the pupils jumps due to Argos cal unit osicllaitons.. In the plots it is observed some jumps in the points.

no shift required.

bin4_20220328.png

TTM bin4

Mon Mar 28 20:34:26.689 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[178] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)bin1 pause

center pupil@360

bin4_ttm_20220328.png

OK

bin1 pause/resume acquire data

Mon Mar 28 21:04:14.626 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[180] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

saved data. The adsec arbitrator went offline.

Open loop.

restart the adsec arbitrator.

StopAO

send again the preset.

Mon Mar 28 21:27:13.794 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[185] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

sent again the preset.

Mon Mar 28 21:39:55.621 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[189] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

TN reference:

5000 frames.

run/save/pause/resume: _215217

10K frames.

run/save/pause/resume:_215323

run/save around 4000/keep in pause->_215409

pause/save frme 4000->resume:_215452.

20220328_215141

apply gain to see a better pupil.

20220328_220542

run/save ~4K/pause ->keep in opause: _220622

pause->save~4k/resume: _220715

run/save/pause `4000/resume ~8000:_220818

run ref: _221658

run/save~2k/resune~8000: 221940

pause/save:_222058

run/save/pause~2000/resume~8000: _222140

run/pause~2000/ :_222231

pause/save/Resume~4000 222314

offset:x+1-1: 222715

JuanCarlosGuerra - 28 Mar 2022
Topic revision: r3 - 28 Mar 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback