Details.

6:13 PM

Telescope zenkith. Doing sky flat.

7:08 pm

preset osco

EL 55

MOON 95%. choosing a different osco star lower but at the shade of the moon.

Tue Mar 15 02:09:08.767 2022 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[1397] - dx:nan dy:nan slNull: f1:0.0 f2:2.0 freq:900 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0

first target, the camera lens moved to +-100 and it required a litte movements from the HW GUI

NCPA ON starting and skipping frames...

ncpa off

reclose loop

optimize +gopt

running without NCPA

5.62,0.98,0.95

1st POSITION, NCAP OFF
=> Command line arguements processed
Set 0 Tracknum 20220315_022035 LuciName unknown
Set 1 Tracknum 20220315_022048 LuciName unknown
Set 2 Tracknum 20220315_022101 LuciName unknown
-> wrote file /home/AOeng/doug/get_telemetry/OSCO/20220315_022035.log

2nd POSITION, NCPA OFF
=> Command line arguements processed
Set 0 Tracknum 20220315_022331 LuciName unknown
Set 1 Tracknum 20220315_022343 LuciName unknown
Set 2 Tracknum 20220315_022356 LuciName unknown
-> wrote file /home/AOeng/doug/get_telemetry/OSCO/20220315_022331.log

7:28 fitst target

bin3

too much moon light,

Estimated magnitude 15.7, correction is suffering. loop closed with Gopt on

optimize_bin3_20220314_night1.png

with a better correction hit about 10% sr

NGS is a double star, separation:

dimm 1.4"

8:15 dimm 1.5"

After the pause, there is a cadence in the estimating magnitude.

8:16pm magnitude to 16

save TN:20220315_032238 + ccd47 PSF

change dimm target.

b3_goodpsf.png

8:24 dimm 1.38"

variable seeing, the corrections seems oscillating..

change target.

next one: core galaxy close loop....

Tue Mar 15 03:29:54.564 2022 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[1498] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:799 mag:0 nBins:2 nModes:250 r0:nan snMode:0 strehl:0 ttMod:0

optimize didn;t work

seeing bubble 2.2"

manual gain.. oscillating, star off the pyramid.

preset Again

8.45 seeing 1.75"-2"

optimize gain failed, start to move away.

stop, no to try more...

8:46 moving to next target.

_035509

tt:0.27,0.07,0.01

_040523

Cancel the preset.

Jopchen check the OT and build a new onbe for ESM

9:06

oscillating TT at 1.9 drop to 1.7 slope rms=0.5

9:12 dimm 1.4"

9:21 dimm 1.12"

dropping gain to 1.55, osilation of the TT

1.55,0.25,0.05

9:34 dimm 1.25"

new target.

Tue Mar 15 04:36:02.115 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1577] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.192959[0.192959],roy:0.61082,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

SEEING 2" BLOWUP THE LOOP.

SHEEL RIP/

\MOVING TO ZENITH

AdSecArbitrator _140942|INF| 61|2022-03-15 04:44:43.520214| MAIN > Received cmd: PowerOn ()
AdSecArbitrator_140942|INF| 62|2022-03-15 04:44:43.520268| COMMANDHANDLER > FSM (status: PowerOn) has received command 2004 (Power on)
AdSecArbitrator_140942|ERR| 63|2022-03-15 04:44:43.520284| COMMANDHANDLER > adsecarb: Fsm is discarding command 2004 (Power on)...
AdSecArbitrator_140942|WAR| 64|2022-03-15 04:44:43.520315| MAIN > PowerOn: WARNING - adsecarb:Illegal command for state PowerOn (Power on)

9:46 POWER OFF/ON

04:48:15.780503| MAIN > Maximum mode index used to apply flat -> # 635

FLAT_AFTER_FAILURE_20220314.png

9:49 CHANGE TO BINOCULAR

10:54. SEEING 2.58"

2:34am configure to luci

seeing seems improved.

2:50 dimm 1"

Tue Mar 15 09:52:10.286 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1603] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.392685[-0.392685],roy:0.263829,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize gain.

TT second pass oscillation. optimize gain failed.

optimize_0307_1pass.png

Second try.

3.34,1.63,0.1

optimize_0307_2pass.png

WfsArbitrator _115021|DEB| 3394|2022-03-15 10:00:58.782733| MAIN > arbFunc doPauseLoop done.
WfsArbitrator_115021|DEB| 3395|2022-03-15 10:01:01.540876| MAIN > arbFunc offsetXYinternal (, 'FLAOWFS', 'LUCIFER', 276.13099999999997, -36.011600000000001, True)
WfsArbitrator_115021|INF| 3396|2022-03-15 10:01:01.546360| MAIN > offsetXY(): starting offset of 276.304, -34.662 mm
WfsArbitrator_115021|INF| 3397|2022-03-15 10:01:01.547293| MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm
WfsArbitrator_115021|ERR| 3398|2022-03-15 10:01:01.547665| MAIN > RETRY: Offset outside FoV limits. Target xyz is 198.05 -84.87 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR

3:04 dimm 1"

object_0307.png

bayside stage: x=-78.2, y=-50.2,z=52.9

large sky offsets.

sky_offset_20220315_0307.png

resume ok

TN:_100948

modal SR ~0.18

Star SR Ks:0.3

TN:_103553

3:38 dimm 1.4-1.2 variable.

TN:_103904

3:43 dimm 1.6"

Tue Mar 15 10:43:49.010 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1675] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.574658[-0.574658],roy:0.152535,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

The gopt is lower than before.

The close loop is with the galaxy core.

3:58 dimm 1.1"

bin3_358_core.png

TN:_110043

loop open.

reclose.

The camera lens has to be moved manually, to ensure a good optimization.

The optimization was lower than before.

TT: 2.5, 1.25

optimizegai_432_bin3_core.png

2022-03-15 11:26:04.684933| -13006 - [AOException] RETRY: Gopt did not stabilize within 10 iterations (-5001) TIMEOUT_ERROR

second try ok.

gopt:0.04,0.02,0

TN:_113356

4:39 dimm 1.1"

Tue Mar 15 11:41:50.464 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1747] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:-0.0299182[-0.0299182],soy:0.257296,rox:-15.0972[-15.0972],roy:-5.05641,mag:15.08,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

no visible in the CCD47

change target

Tue Mar 15 11:50:23.787 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1751] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:-0.0299182[-0.0299182],soy:0.257296,rox:-15.0862[-15.0862],roy:-5.05821,mag:16.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

acq_veryfaint_16p2.png

No visible in the CCD47.

hard to get the acquisition.

Tue Mar 15 11:54:30.126 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1755] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:-0.0239346[-0.0239346],soy:0.574429,rox:-58.2482[-58.2482],roy:-9.28578,mag:14.75,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

tt1.35,0.35 sloperms=0.8

5:00 dimm 1.2"

12:00:43.861539| MAIN > arbFunc doPauseLoop done.
WfsArbitrator_115021|DEB| 4373|2022-03-15 12:00:46.818575| MAIN > arbFunc offsetXYinternal (, 'FLAOWFS', 'LUCIFER', 0.509768, -24.855799999999999, True)
WfsArbitrator_115021|INF| 4374|2022-03-15 12:00:46.818830| MAIN > offsetXY(): starting offset of 0.631, -24.853 mm
WfsArbitrator_115021|INF| 4375|2022-03-15 12:00:46.819604| MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm
WfsArbitrator_115021|INF| 4376|2022-03-15 12:01:28.689859| MAIN > Stage movement timeout after 40 seconds. Retry 1 of 3
WfsArbitrator_115021|INF| 4377|2022-03-15 12:02:11.780567| MAIN > Stage movement timeout after 40 seconds. Retry 2 of 3
WfsArbitrator_115021|ERR| 4378|2022-03-15 12:02:54.908822| MAIN > RETRY: Stages position not reached (-5001) TIMEOUT_ERROR

2022-03-15 12:08:36.255155| MAIN > arbFunc offsetXYinternal done.
WfsArbitrator_115021|DEB| 4406|2022-03-15 12:08:36.888697| MAIN > arbFunc doResumeLoop (, 'FLAOWFS', 'LUCIFER')
WfsArbitrator_115021|INF| 4407|2022-03-15 12:08:36.990137| MAIN > Total counts/subap: 5.286250 - framerate: 400.0 - Flux: 4
WfsArbitrator_115021|INF| 4408|2022-03-15 12:08:36.990614| MAIN > Star magnitude on WFS changed from 16.5 to 19.4
WfsArbitrator_115021|INF| 4409|2022-03-15 12:08:36.990661| MAIN > resumeLoop not executed - loop still paused
WfsArbitrator_115021|ERR| 4410|2022-03-15 12:08:36.990714| MAIN > RETRY: Star not found - loop still paused (-20002) WFSARB_STA

it seems that the offset wne to the position of the vigetting of the patrol field.

Dave took a manual image.

offset back to zero zero. star back and it is center.

same issue

12:15:07.039454| MAIN > arbFunc offsetXYinternal (, 'FLAOWFS', 'LUCIFER', 0.68891800000000003, -24.375, True)
WfsArbitrator_115021|INF| 4434|2022-03-15 12:15:07.039715| MAIN > offsetXY(): starting offset of 0.808, -24.371 m

upated it #8602

resume..

star no in the CCD47.

Loop opne AOSet.

Steve adjust the offsets to bring the star to the PyWFS,.

reclose

tt:1.35,0.55 slope rms=0.44

Same offset worked.

bayside stage: x=-19.Y=-61

|DEB| 4544|2022-03-15 12:49:22.067803| MAIN > arbFunc offsetXYinternal (, 'FLAOWFS', 'LUCIFER', -0.63407000000000002, -24.674499999999998, True)
WfsArbitrator_115021|INF| 4545|2022-03-15 12:49:22.068063| MAIN > offsetXY(): starting offset of -0.513, -24.677 mm
WfsArbitrator_115021|INF| 4546|2022-03-15 12:49:22.074736| MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm
WfsArbitrator_115021|ERR| 4547|2022-03-15 12:49:22.075137| MAIN > RETRY: Offset outside FoV limits. Target xyz is -19.90 -86.10 53.25 (-5002) VALUE_OUT_OF_RANGE_ERROR

BACK OFFSET DIDN;T BRING THE STAR TO THE HOT SPOT.

notch telescope.. CLOSING WITh THE SKY

RIP

TELESCOPE TO ZENITH to recover the adsec.

FLAT OK

12:59:49.079849| MAIN > Maximum mode index used to apply flat -> # 635

FLAT_20220316_6P0.png

-- JuanCarlosGuerra - 15 Mar 2022
I Attachment Action Size Date Who Comment
FLAT_20220316_6P0.pngpng FLAT_20220316_6P0.png manage 131 K 15 Mar 2022 - 13:01 JuanCarlosGuerra  
FLAT_AFTER_FAILURE_20220314.pngpng FLAT_AFTER_FAILURE_20220314.png manage 150 K 15 Mar 2022 - 04:49 JuanCarlosGuerra  
acq_veryfaint_16p2.pngpng acq_veryfaint_16p2.png manage 45 K 15 Mar 2022 - 11:53 JuanCarlosGuerra  
b3_goodpsf.pngpng b3_goodpsf.png manage 387 K 16 Mar 2022 - 01:32 JuanCarlosGuerra  
bin3_358_core.pngpng bin3_358_core.png manage 35 K 15 Mar 2022 - 10:59 JuanCarlosGuerra  
object_0307.pngpng object_0307.png manage 33 K 15 Mar 2022 - 10:19 JuanCarlosGuerra  
optimize_0307_1pass.pngpng optimize_0307_1pass.png manage 179 K 15 Mar 2022 - 10:27 JuanCarlosGuerra  
optimize_0307_2pass.pngpng optimize_0307_2pass.png manage 181 K 15 Mar 2022 - 10:27 JuanCarlosGuerra  
optimize_bin3_20220314_night1.pngpng optimize_bin3_20220314_night1.png manage 223 K 15 Mar 2022 - 03:19 JuanCarlosGuerra  
optimizegai_432_bin3_core.pngpng optimizegai_432_bin3_core.png manage 157 K 15 Mar 2022 - 11:32 JuanCarlosGuerra  
sky_offset_20220315_0307.pngpng sky_offset_20220315_0307.png manage 150 K 15 Mar 2022 - 10:07 JuanCarlosGuerra  
Topic revision: r6 - 16 Mar 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback