Pupil wobble check for the 4 binnings, to confirm the shift for Bin2. Shift applied for Bin2.

Not much time to perfoirm another test with bin3 Gopt.

Details.

SEcond failure fo the power on

WfsArbitrator _115021|ERR| 114|2022-03-14 15:34:46.287784| MAIN > Exception: Timeout waiting for ocam2.L.STATUS
WfsArbitrator_115021|ERR| 115|2022-03-14 15:34:46.287844| MAIN > Timeout waiting for ocam2.L.STATUS (-5001) TIMEOUT_ERROR

Using the HW gui to power on the Box47 after a operater and passed the ocam2 power on.

test preset.

Mon Mar 14 15:47:51.853 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1367] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

ocam. not live.

AO prepared but ocam not live.

bcu 2k power cycle.

OK

Mon Mar 14 15:52:03.791 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1368] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

WfsArbitrator _115021|DEB| 417|2022-03-14 15:55:39.704994| MAIN > arbFunc doCenterPupils (, 'FLAOWFS', 'LUCIFER')
WfsArbitrator_115021|ERR| 418|2022-03-14 15:55:39.705914| MAIN > RETRY: Camera lens temperature too low. T= 4.11, minimum allowed is 7.00 (0) N

WfsArbitrator _115021|ERR| 420|2022-03-14 16:06:05.011990| MAIN > RETRY: Camera lens temperature too low. T= 6.21, minimum allowed is 7.00 (0) NO_ER

chamber air temperature : -1.26C

ocam2k viewer not live with the loop clsed. open loop and ocam live again.

loop closed and it is not sending slopes.

adsc_stop/start.

adsec flat

4 16:21:52.422843| MAIN > Maximum mode index used to apply flat -> # 635

Mon Mar 14 16:22:54.234 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1370] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

BIN1 Wobble

9:26

bin1_20220314.png

BIN2 Wobble.

Mon Mar 14 16:45:07.352 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1372] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

the acquision showed the camera lens was not moving. Move manually the axes usi g the HW gui.

many jump is the pupils during the rotaiton.

Shift in X positive, one pixel.

Pupil to check!

>>> makePupils.movePupils('20211125_011619',1,0,240,3)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220314_170753/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220314_170753/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 328
out_of_pupil_slopes 2192
lines_to_add 10
residual_pixels_to_add 8
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220314_170753
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220314_170753"
'20220314_170753'
>>>

At angle 280 loop opne, it didn;t load the gain.

Setting rotator position 280
ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 280.000000 left\" | tcsh"
Resmsg[0] = RotServicePosition result status: OK
Resmsg[1] = OK
----------------------------------------------
0.1 0.0395833 0.0
Traceback (most recent call last):
File "/home/AOeng/live/aoroot/bin/wobble_test_forward.py", line 15, in <module>
g = adsec.get_gains()
File "/home/AOeng/live/aoroot/lib/python/AdOpt/asm.py", line 71, in get_gains
return fits_lib.readSimpleFits(gainpath)
File "/home/AOeng/live/aoroot/lib/python/AdOpt/fits_lib.py", line 87, in readSimpleFits
fitsobj = pyfits.open(filename, ignore_missing_end=True)
File "/usr/lib64/python2.6/site-packages/pyfits/core.py", line 10729, in open
ffo = _File(name, mode=mode, memmap=memmap, **parms)
File "/usr/lib64/python2.6/site-packages/pyfits/core.py", line 9350, in init__
self.__file=__builtin
.open(self.name, _python_mode[mode])
IOError: [Errno 21] Is a directory: '/local/aomeas/adsec_calib/M2C/'
[AOeng@soul-sxwfs scripts]$

saw a roll over edge.(?)

Mon Mar 14 17:21:13.326 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1375] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.4,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 14 17

apply pupil change.

10:27

stop

>>> makePupils.movePupils('20211125_011619',-1,0,240,3)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220314_172944/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220314_172944/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 328
out_of_pupil_slopes 2192
lines_to_add 10
residual_pixels_to_add 8
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220314_172944
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220314_172944"
'20220314_172944'

10:37

loaded pupil: '20220314_170753'

rot@341

x=38, y=25

ok.

change offsetbin2 x from 2 to 3

check first rotation.

ok

bin2_20220314_shift.png

to be changed in the AO table.

bin3 wobble.

Mon Mar 14 18:08:07.607 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1379] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

start 11:15

bin3_20220314.png

bin4 wobble.

Mon Mar 14 18:35:10.415 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1381] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

11:42

bin4_20220314.png

handover 12:15PM

-- JuanCarlosGuerra - 14 Mar 2022
Topic revision: r1 - 14 Mar 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.