Power on 7:30am

OK.

Ocam frames OK.

Adsec flat

ok.

> Maximum mode index used to apply flat -> # 635

flat_20220304.png

-

TEST PRESET BIN1 WITH DISTURBANCE.

Fri Mar 4 15:43:20.685 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[768] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Mar 4 15:43:20.706 2022 aos.info - WFS source set to: FLAOWFS
Fri Mar 4 15:43:20.845 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Fri Mar 4 15:43:22.

9:37 AM issues with the Argos cal unit white source.

Paul is checking..

9:50am gui is back

No PSF found in the CCD47, scanning with the hexapod and it not found.

Remove Argos cal unit to take a pupil image with Luci, just to verify that the light is on and shutter open.

Check luci image and it looks like the light source is ON.

back to N30 configuration.

Argos cal unit in the beam.

Init/home the hexapod.

PSF in the field.

Close loop with disturbance on for Bin1.

gopt:1.24,0.27,0.28

tn+luci: 20220304_180608 (single image)

residual wavefront rms: (TT, tot w/o TT): 261.211, 138.108

tn+luci,_180803

psf-180803.png

residual wavefront rms: (TT, tot w/o TT): 370.936, 169.531

ncpa on

_180907

shows many vibraions duringthe close loop, this affects the TT, also there some spikes at high frequencies and the modal plot shows oscillaitons of the high order modes.

residual wavefront rms (TT, tot w/o TT): 715.319, 213.168

psf-180907.png

to be confirm with a new data set.

handover to telescope at 11:15AM

home Pupil rerotator.

Resume

2:17PM

close loop

no dist

Fri Mar 4 21:18:26.413 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[783] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Mar 4 21:18:26.429

Tn: _212335,212501,_212633

the third shows a small deep of the SR.

ncpaON

_212815,_212936,_213045

deep in the SR plot.

3rd tn shows spikes...

home Pupil rerotator.

Resume

2:17PM

close loop

no dist

Fri Mar 4 21:33:37.021 2022 aos.PresetAO{FLAO}.complete - PresetAO{FLAO}[787] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:900 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0nddir:nan)
Fri Mar 4 21:33:03.183 2022 aos.info - WFS source set to: FLAOWFS
Fri Mar 4 21:33:03.248 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Fri Mar 4 21:33:04.055 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

TN+luci:_214113,_214225,_214410

second tn done;t have the luci

ncpaON

tn+luci:_214607,_some jitter detected, _214707(jitter detected),_214841,_215050

jitter_20220304_214607.png

BIN3 FAINT.

LOADED TURBULENCE 1"

Fri Mar 4 21:54:19.791 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[792] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.4,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Mar 4 21:54:19.806 2022 aos.info - WFS source set to: FLAOWFS
Fri Mar 4 21:54:19.864 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq200.0000_sd3892.fits
Fri Mar 4 21:54:20.698 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

OPTIMIZE

OPTIMKZE_BIN3_FAINT_20220304.png

TN:_220212,_220350(20),_220545(no good),_220658(J band),_

3:09 power bump

Adsec to failure. the wind speed not available

adsc_stop/start.

set flat.

22:16:25.093218| MAIN > Maximum mode index used to apply flat -> # 635

looking at the ocam it seems that it power off the controller.

Power on the WFS.

22:38:35.232920| MAIN > Maximum mode index used to apply flat -> # 635

pause/restarting.

Not PSF in the CCD47, searching for the

4:15 PM Stop not too much time left.