Summary.

Several system checks to be perform.

Pupl wobble for 4 bin.

Bin2 optimize gain change max iterations to 4. Acquire PSF

Bin3 optimize gain; manual vs auto. Acquire PSF

Details.

Startup up system.

OK.

Ocam: OK

9:50 . temperature bcu47 =-2

9:53 temperature bcu47=1.72

temperature has to reach 7 degrees.

Luci. Initiallize al

9:57 bcu47 temp=0

9:59 temp= 0.7C

10:01 temp=1.5C

test preset.

Tue Feb 22 17:27:26.459 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[445] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

No disturbance.

Tue Feb 22 17:29:53.910 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[446] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

close loop auto mode.

selectHODark(): selected dark file 20220222_173843.fits

good optimize, no skip frames...

TN:20220222_174116,. No luci

luci dark n3.75 camera

46:13.351958| MAIN > saveCalibFile(): saved as 20220222_174613

tn+luci(3.75):_174652

luci1.20220222.0004.

TN+luci:_175033

bin1 wobble check.

start 10:57

bin1_20220223.png

bin2 wobble check.

shutter 56

Tue Feb 22 18:13:52.911 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[452] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

pupil: 20211125_011619

start: 11:19

bin2_20220223.png

POSSIBLE SHIFT TO APPLY

>>> makePupils.movePupils('20211125_011619',1,0,240,3)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/oam2/LUTs/mode3/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LTs/mode3/20220222_183450/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pupdata.xt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220222_183450pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 328
out_of_pupil_slopes 2192
lines_to_add 10
residual_pixels_to_add 8
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/currnt/ocam2/LUTs/mode3 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mod3/20220222_183450
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/pup1.fit" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode3/20220222_183450"
'20220222_183450'

BIN3 WOBBLE check.

Tue Feb 22 18:37:07.320 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[454] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

pupil:20200119_035330

bin3_20220223.png

bin4 wobble check

pupil:20211205_144238

Tue Feb 22 19:04:39.588 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[456] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

open loop at 20 degrees down.

reclose

bin4_20220223.png

check bin2 optimize

change autogain.conf for bin2

bin2_f2_max_iterations int 4

loaded disturbance 1"

Tue Feb 22 19:38:37.202 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[458] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 19:38:37.215 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 22 19:38:37.275 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits
Tue Feb 22 19:38:38.114 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

the reset went to Bin3

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 19:40:01.900 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 22 19:40:01.967 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits
Tue Feb 22 19:40:02.665 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

cancel preset.

-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 19:49:55.211 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 22 19:49:55.269 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits
Tue Feb 22 19:49:55.962 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

optimize

optimize_bin2changefactorto4.png

gopt.

2022-02-22 19:58:32.182653| -13006 - [AOException] RETRY: Optical gain is not one, cannot start tracking (-5002) VALUE_OUT_OF_RANGE_ERROR

optimize gain second run

gopt ok

TN:_200151

TN+luci:_200215,_200353

luci1.20220223.0003,0002

bin3 optimize gain manual vs auto

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 20:15:10.836 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 22 20:15:10.903 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.0000_sd3892.fits

cancel preset, it loaded 800Hz loop frequency.

loaded a diffferent turbulance speed.

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 20:17:58.626 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 22 20:17:58.688 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits
Tue Feb 22 20:17:59.346 2022 aos.info - FLAO: WFS: loading s

skip frame

interrupt the command

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 20:17:58.626 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 22 20:17:58.688 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits
Tue Feb 22 20:17:59.346 2022 aos.info - FLAO: WFS: loading s

optimize Auto

4.58,1.31,0.10

rms slope:0.62

TN+Luci:_203948,_204318

4.58,1.06,0.1

rms:0.61

TN+Luci:_204604

4.63,0.91,0.1

tn+luci:_204730

rms:0.61

4.58,1.36,0.10

_204926

4.58,1.61,0.25

rms:0.6-0.59

tn+luci:_205116

4.38,1.76,0.25

rns:0.58

tn+luci:_205243

after a few minutes running skip 100...

stop loop

Tue Feb 22 20:56:18.163 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[470] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 20:56:18.178 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 22 20:56:18.240 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits
Tue Feb 22 20:56:18.957 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

optimize auto

3.55,1.53,0.10

rms:0.62

tn+luci:_210128

3.55,1.73,01.

skip open loop

Tue Feb 22 21:05:10.855 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[472] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 21:05:10.869 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 22 21:05:10.932 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits
Tue Feb 22 21:05:11.629 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

optimize auto

3.64,1.43,0.10

_210932

ncap on

_211041

3.64,1.53,0.1

_211221

ncpa on

_skip frames.

Tue Feb 22 21:21:06.207 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[474] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 21:21:06.222 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 22 21:21:06.286 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits
Tue Feb 22 21:21:06.983 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

RAMP GAIN TEST.

join with Brandon to test the ramp gain applied after the resume AO

[AOeng@sxadsec source]$ use_soul
Usage: use_soul [version]
Currently running: test.20220222.reorder-gain-ramp
Available versions:
latest
stable
stable.20211011.pause-resume
stable.20211125
test.20220215.hk-partial-timeout
test.20220222.reorder-gain-ramp
[AOeng@sxadsec source]$

adsec arbitrator went down after the load program success.

restart.

Set flat

ok

Tue Feb 22 21:44:00.453 2022 aos.info - FLAO: Adsec 672b-left shell set done.
Tue Feb 22 21:45:00.473 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[476] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 22 21:45:00.488 20

auto mode

pause

gain0

NDHANDLER > Command Pause Ao (code 2027) successfully completed
AdSecArbitrator_90777|INF| 172|2022-02-22 21:51:57.736216| MAIN > Received cmd: ResumeAo ()
AdSecArbitrator_90777|INF| 173|2022-02-22 21:51:57.736330| COMMANDHANDLER > FSM (status: AOPause) has received command 2028 (ResumeAo Ao)
AdSecArbitrator_90777|INF| 174|2022-02-22 21:51:57.743735| COMMANDHANDLER > Command ResumeAo Ao (code 2028) successfully completed
AdSecArbitrator_90777|INF| 175|2022-02-22 21:51:57.883003| MAIN > Received cmd: Offloading(1)

_90623 |INF| 3776|2022-02-22 21:52:46.000745| MAIN > Executing command: errcode= fsm_set_gain('/local/aomeas/adsec_calib/M2C/KL/gain/gain0.fits', BANK=1) & print, errcode
idl_ctrl_90623 |INF| 3777|2022-02-22 21:52:46.000911| MAIN > StartCmd
idl_ctrl_90623 |INF| 3778|2022-02-22 21:52:46.005557| MAIN > 0
idl_ctrl_90623 |INF| 3779|2022-02-22 21:52:46.005601| MAIN > % READFITS: Now reading 672 element array
idl_ctrl_90623 |INF| 3779|2022-02-22 21:52:46.005601| MAIN > .
idl_ctrl_90623 |INF| 3780|2022-02-22 21:52:46.005620| MAIN > EndCmd
idl_ctrl_90623 |INF| 3781|2022-02-22 21:52:46.005913| MAIN > Executing command: errcode= fsm_pause_ao() & print, errcode
idl_ctrl_90623 |INF| 3782|2022-02-22 21:52:46.005992| MAIN > StartCmd
idl_ctrl_90623 |INF| 3783|2022-02-22 21:52:46.007993| MAIN > 0
idl_ctrl_90623 |INF| 3784|2022-02-22 21:52:46.008019| MAIN > EndCmd

3789|2022-02-22 21:53:09.589997| MAIN > Executing command: errcode= fsm_set_gain('/local/aomeas/adsec_calib/M2C/KL_v20/gain/g_tt_1.15_ho1_0.11_ho2_0.17.fits', BANK=1) & print, errcode
idl_ctrl_90623 |INF| 3790|2022-02-22 21:53:09.590205| MAIN > StartCmd
idl_ctrl_90623 |INF| 3791|2022-02-22 21:53:09.595028| MAIN > 0
idl_ctrl_90623 |INF| 3792|2022-02-22 21:53:09.595048| MAIN > % READFITS: Now reading 672 element array
idl_ctrl_90623 |INF| 3792|2022-02-22 21:53:09.595048| MAIN > .
idl_ctrl_90623 |INF| 3793|2022-02-22 21:53:09.595062| MAIN > EndCmd
idl_ctrl_90623 |INF| 3794|2022-02-22 21:53:09.595263| MAIN > Executing command: errcode= fsm_resume_ao() & print, errcode
idl_ctrl_90623 |INF| 3795|2022-02-22 21:53:09.595344| MAIN > StartCmd
idl_ctrl_90623 |INF| 3796|2022-02-22 21:53:09.597063| MAIN > 0
idl_ctrl_90623 |INF| 3797|2022-02-22 21:53:09.597086| MAIN > EndCmd

delay set to 0

restart arbitrator.

Tue Feb 22 21:58:42.967 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[485] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

2-02-22 22:04:38.212882| MAIN > Executing command: errcode= fsm_set_gain('/local/aomeas/adsec_calib/M2C/KL/gain/gain0.fits', BANK=1) & print, errcode
idl_ctrl_90623 |INF| 7439|2022-02-22 22:04:38.213057| MAIN > StartCmd
idl_ctrl_90623 |INF| 7440|2022-02-22 22:04:38.218396| MAIN > 0
idl_ctrl_90623 |INF| 7441|2022-02-22 22:04:38.218427| MAIN > % READFITS: Now reading 672 element array
idl_ctrl_90623 |INF| 7441|2022-02-22 22:04:38.218427| MAIN > .
idl_ctrl_90623 |INF| 7442|2022-02-22 22:04:38.218443| MAIN > EndCmd
idl_ctrl_90623 |INF| 7443|2022-02-22 22:04:38.218651| MAIN > Executing command: errcode= fsm_pause_ao() & print, errcode
idl_ctrl_90623 |INF| 7444|2022-02-22 22:04:38.218689| MAIN > StartCmd
idl_ctrl_90623 |INF| 7445|2022-02-22 22:04:38.220582| MAIN > 0

22 22:05:13.161854| MAIN > Executing command: errcode= fsm_resume_ao() & print, errcode
idl_ctrl_90623 |INF| 7451|2022-02-22 22:05:13.161970| MAIN > StartCmd
idl_ctrl_90623 |INF| 7452|2022-02-22 22:05:13.164641| MAIN > 0
idl_ctrl_90623 |INF| 7452|2022-02-22 22:05:13.164641| MAIN > . EndCmd
idl_ctrl_90623 |INF| 7453|2022-02-22 22:05:13.165171| MAIN > Executing command: errcode= fsm_set_gain('/local/aomeas/adsec_calib/M2C/KL_v20/gain/g_tt_1.42_ho1_0.11_ho2_0.16.fits', BANK=1, CLIP_N_MODES=10, SCALE=0.1) & print, errcode
idl_ctrl_90623 |INF| 7454|2022-02-22 22:05:13.165235| MAIN > StartCmd
idl_ctrl_90623 |INF| 7455|2022-02-22 22:05:13.170334| MAIN > 0
idl_ctrl_90623 |INF| 7455|2022-02-22 22:05:13.170334| MAIN > . EndCmd
idl_ctrl_90623 |INF| 7456|2022-02-22 22:05:13.170376| MAIN > % READFITS: Now reading 672 element array
idl_ctrl_90623 |INF| 7456|2022-02-22 22:05:13.170376| MAIN > .
idl_ctrl_90623 |INF| 7457|2022-02-22 22:05:14.170950| MAIN > Executing command: errcode= fsm_set_gain('/local/aomeas/adsec_calib/M2C/KL_v20/gain/g_tt_1.42_ho1_0.11_ho2_0.16.fits', BANK=1) & print, errcode
idl_ctrl_90623 |INF| 7458|2022-02-22 22:05:14.171060| MAIN > StartCmd

Feb 22 22:05:14.865 2022 aos.Resume{FLAO}.complete - Resume{FLAO}[444]
Tue Feb 22 22:05:16.322 2022 aos.info - TTF offload: previous 2 requests ignored
Tue Feb 22 22:05:16.341 2022 aos.info - TTF Offload request (FLAO) Z: 0.0307813 0.0231953 -0.000119307
Tue Feb 22 22:05:19.146 2022 aos.info - TTF offload command end
Tue Feb 22 22:05:19.292 2022 aos.info - TTF offload: previous 1 requests ignored

e Feb 22 22:06:40.648 2022 aos.Resume{FLAO}.started - Resume{FLAO}[444]
Tue Feb 22 22:06:41.816 2022 aos.info - AO loop closed
Tue Feb 22 22:06:41.816 2022 aos.Resume{FLAO}.complete - Resume{FLAO}[444]
Tue Feb 22 22:06:42.421 2022 aos.info - TTF offload: previous 3 requests ignored
Tue Feb 22 22:06:42.434 2022 aos.info - TTF Offload request (FLAO) Z: -0.0387856 -0.00424531 -7.92884e-05
Tue Feb 22 22:06:45.242 2022 aos.info - TTF offload command end
Tue Feb 22 22:06:45.420 2022 aos.info - TTF Offload request (FLAO) Z: 0.0325031 0.115938 -6.8999e-05
Tue Feb 22 22:06:48.752 2022 aos.info - TTF offload command end
Tue Feb 22 22:06:49.420 2022 aos.info - TTF offload: previous 3 requests ignored
Tue Feb 22 22:06:49.435 2022 aos.info - TTF Offload request (FLAO) Z: -0.0455368 -0.100068 -0.000104566

74|2022-02-22 22:06:40.667258| MAIN > Executing command: errcode= fsm_resume_ao() & print, errcode
idl_ctrl_90623 |INF| 7475|2022-02-22 22:06:40.667416| MAIN > StartCmd
idl_ctrl_90623 |INF| 7476|2022-02-22 22:06:40.669353| MAIN > 0
idl_ctrl_90623 |INF| 7477|2022-02-22 22:06:40.669383| MAIN > EndCmd
idl_ctrl_90623 |INF| 7478|2022-02-22 22:06:40.669746| MAIN > Executing command: errcode= fsm_set_gain('/local/aomeas/adsec_calib/M2C/KL_v20/gain/g_tt_1.42_ho1_0.11_ho2_0.16.fits', BANK=1, CLIP_N_MODES=10, SCALE=0.1) & print, errcode
idl_ctrl_90623 |INF| 7479|2022-02-22 22:06:40.669791| MAIN > StartCmd
idl_ctrl_90623 |INF| 7480|2022-02-22 22:06:40.673520| MAIN > 0
idl_ctrl_90623 |INF| 7481|2022-02-22 22:06:40.673548| MAIN > % READFITS: Now reading 672 element array
idl_ctrl_90623 |INF| 7481|2022-02-22 22:06:40.673548| MAIN > .
idl_ctrl_90623 |INF| 7482|2022-02-22 22:06:40.673563| MAIN > EndCmd
idl_ctrl_90623 |INF| 7483|2022-02-22 22:06:41.674031| MAIN > Executing command: errcode= fsm_set_gain('/local/aomeas/adsec_calib/M2C/KL_v20/gain/g_tt_1.42_ho1_0.11_ho2_0.16.fits', BANK=1) & print, errcode
idl_ctrl_90623 |INF| 7484|2022-02-22 22:06:41.674180| MAIN > StartCmd

pause saving TN_

pause tn:-220939

tn+resume

-222040

pause

TN:_221758.

tn+resume

Feb 22 22:18:36.997 2022 aos.info - AO loop closed
Tue Feb 22 22:18:36.998 2022 aos.Resume{FLAO}.complete - Resume{FLAO}[444]
Tue Feb 22 22:18:37.547 2022 aos.info - TTF offload: previous 2 requests ignored
Tue Feb 22 22:18:37.561 2022 aos.info - TTF Offload request (FLAO) Z: -0.00897569 -0.14027 -3.97021e-05
Tue Feb 22 22:18:40.561 2022 aos.info - TTF offload command end

_221858

stop

back to stable version.

flat->ok

The step gain is applied after the resume is executed. it is not viible any different effect. It should be tested night time with the offsets and the time.

-- JuanCarlosGuerra - 22 Feb 2022