Details.

vncviewer connection to laos2.

laos2_screen0.png

8:15 am Waiting to have a decision to use the Adsec.

Floarina building a bias for the CCD, there is a drift to compensate.

8:49 am Still waiting from an official decision to use the Adsec.

9:30 am green light to proceed.

  • LN test fastlink ok
  • send startloop .OK
  • python script worked.
  • load the reconstructor.
  • 0|INF| 112|2022-02-17 16:46:25.415148| MAIN > Received cmd: LoadRecMat(m2c[672,672], RecMat[672,1600],0)
    AdSecArbitrator_87040|INF| 113|2022-02-17 16:46:25.437276| COMMANDHANDLER > FSM (status: AOSet) has received command 2022 (SetRecMat)
    idl_86869 |INF| 1512|2022-02-17 16:46:25.438260| MAIN > Loading: /tmp/LNRecmat.fits
    idl_86869 |INF| 1513|2022-02-17 16:46:25.442378| MAIN > Wrong dimensions of reconstruction matrix (B0) matrix in input
    idl_86869 |INF| 1514|2022-02-17 16:46:25.457652| MAIN > IDL Invalid/Uncoherent input parameters
    20221702 16:46:25.4585 Alert: Warning: setRecMat not executed (retry)
    AdSecArbitrator_87040|WAR| 114|2022-02-17 16:46:25.457921| IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
    AdSecArbitrator_87040|INF| 115|2022-02-17 16:46:25.458233| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
    AdSecArbitrator_87040|WAR| 116|2022-02-17 16:46:25.458306| MAIN > LoadRecMat: WARNING - IDL Invalid/Uncoherent input parameters

  • AdSecArbitrator_87040|INF| 117|2022-02-17 16:50:32.427124| MAIN > Received cmd: LoadRecMat(m2c[672,672], RecMat[672,1600],0)
    AdSecArbitrator_87040|INF| 118|2022-02-17 16:50:32.450413| COMMANDHANDLER > FSM (status: AOSet) has received command 2022 (SetRecMat)
    idl_86869 |INF| 1515|2022-02-17 16:50:32.451379| MAIN > Loading: /tmp/LNRecmat.fits
    idl_86869 |INF| 1516|2022-02-17 16:50:32.455284| MAIN > Wrong dimensions of reconstruction matrix (B0) matrix in input
    idl_86869 |INF| 1517|2022-02-17 16:50:32.455336| MAIN > IDL Invalid/Uncoherent input parameters
    20221702 16:50:32.4560 Alert: Warning: setRecMat not executed (retry)
    AdSecArbitrator_87040|WAR| 119|2022-02-17 16:50:32.455588| IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
    AdSecArbitrator_87040|INF| 120|2022-02-17 16:50:32.455791| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
    AdSecArbitrator_87040|WAR| 121|2022-02-17 16:50:32.455824| MAIN > LoadRecMat: WARNING - IDL Invalid/Uncoherent input parameters
    20221702 16:50:33.2793 Alert: HighOrderOffload: HighOrderOffload vector ready
    20221702 16:50:53.3178 Alert: HighOrderOffload: HighOrderOffload vector ready

  • debugging..
  • ecArbitrator_87040|INF| 122|2022-02-17 16:58:21.165250| MAIN > Received cmd: LoadRecMat(m2c[672,672], RecMat[672,2848],0)
  • AdSecArbitrator_87040|INF| 123|2022-02-17 16:58:21.201170| COMMANDHANDLER > FSM (status: AOSet) has received command 2022 (SetRecMat)
  • idl_86869 |INF| 1518|2022-02-17 16:58:21.201946| MAIN > Loading: /tmp/LNRecmat.fits
  • idl_86869 |INF| 1519|2022-02-17 16:58:21.280777| MAIN > Wrong dimensions of slope delay matrix (B_DELAY) in input
  • idl_86869 |INF| 1520|2022-02-17 16:58:21.280845| MAIN > IDL Invalid/Uncoherent input parameters
  • 20221702 16:58:21.2817 Alert: Warning: setRecMat not executed (retry)
  • AdSecArbitrator_87040|WAR| 124|2022-02-17 16:58:21.281058| IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
  • AdSecArbitrator_87040|INF| 125|2022-02-17 16:58:21.281285| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
  • AdSecArbitrator_87040|WAR| 126|2022-02-17 16:58:21.281348| MAIN > LoadRecMat: WARNING - IDL Invalid/Uncoherent input parameters
  • 20221702 16:58:34.6796 Alert: HighOrderOffload: HighOrderOffload vector ready

Testing KL_18 and it didn;t work.

Try a Soul KL_18 and it didn't work.

To build new Rec for KL_20.

AdSecArbitrator_87040|INF| 151|2022-02-17 17:26:35.384338| COMMANDHANDLER > FSM (status: AOSet) has received command 2022 (SetRecMat)
idl_86869 |INF| 1551|2022-02-17 17:26:35.385119| MAIN > Loading: /tmp/LNRecmat.fits
AdSecArbitrator_87040|INF| 152|2022-02-17 17:26:36.244286| COMMANDHANDLER > Command SetRecMat (code 2022) successfully completed
AdSecArbitrator_87040|INF| 153|2022-02-17 17:26:36.413245| MAIN > Received cmd: LoadRecMat(m2c[672,672], RecMat[672,2848],1)
AdSecArbitrator_87040|INF| 154|2022-02-17 17:26:36.449361| COMMANDHANDLER > FSM (status: AOSet) has received command 2022 (SetRecMat)
idl_86869 |INF| 1553|2022-02-17 17:26:36.464580| MAIN > Wrong dimensions of slope delay matrix (B_DELAY) in input
idl_86869 |INF| 1554|2022-02-17 17:26:36.464672| MAIN > IDL Invalid/Uncoherent input parameters
20221702 17:26:36.4655 Alert: Warning: setRecMat not executed (retry)
AdSecArbitrator_87040|WAR| 155|2022-02-17 17:26:36.464846| IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
AdSecArbitrator_87040|INF| 156|2022-02-17 17:26:36.465093| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator_87040|WAR| 157|2022-02-17 17:26:36.465144| MAIN > LoadRecMat: WARNING - IDL Invalid/Uncoherent input parameters
20221702 17:26:55.7935 Alert: HighOrderOffload: HighOrderOffload vector ready

loaded the matrix

dl_ctrl_86832 |INF| 5252|2022-02-17 17:34:14.346811| MAIN > Executing command: errcode= fsm_load_rec(M2C_F='/tmp/LNm2c.fits', REC_MAT_F='/tmp/LNRecmat.fits', A_DELAY_F='/local/aomeas/adsec_calib/M2C/KL_v20/filtering/pureIntegratorSOUL/mode_delay.fits', B_DELAY_F='/local/aomeas/adsec_calib/M2C/KL_v20/filtering/pureIntegratorSOUL/slope_delay.fits', BANK=1, /NOBLOCKCHECK) & print, errcode
idl_ctrl_86832 |INF| 5253|2022-02-17 17:34:14.346932| MAIN > StartCmd
idl_ctrl_86832 |INF| 5254|2022-02-17 17:34:14.347396| MAIN > Loading: /tmp/LNRecmat.fits
idl_ctrl_86832 |INF| 5255|2022-02-17 17:34:15.167469| MAIN > Loading 496 modes
idl_ctrl_86832 |INF| 5256|2022-02-17 17:34:15.167523| MAIN > % READFITS: Now reading 2848 by 672 array
idl_ctrl_86832 |INF| 5256|2022-02-17 17:34:15.167523| MAIN > . % READFITS: Now reading 672 by 672 by 2 array
idl_ctrl_86832 |INF| 5256|2022-02-17 17:34:15.167523| MAIN > . % READFITS: Now reading 2848 by 672 array
idl_ctrl_86832 |INF| 5256|2022-02-17 17:34:15.167523| MAIN > . % READFITS: Now reading 672 by 672 array
idl_ctrl_86832 |INF| 5256|2022-02-17 17:34:15.167523| MAIN > .
idl_ctrl_86832 |INF| 5257|2022-02-17 17:34:15.168236| MAIN > Settings:
idl_ctrl_86832 |INF| 5258|2022-02-17 17:34:15.168275| MAIN > Skip threshold: MAX DELTA MODE 0.000260000
idl_ctrl_86832 |INF| 5259|2022-02-17 17:34:15.168340| MAIN > Skip threshold: MAX ABS MODE 0.000130000
idl_ctrl_86832 |INF| 5260|2022-02-17 17:34:15.168377| MAIN > Skip threshold: DELTA COMMAND 1.00000e-05
idl_ctrl_86832 |INF| 5261|2022-02-17 17:34:15.168434| MAIN > Skip threshold: MAX COMMAND 7.30000e-05
idl_ctrl_86832 |INF| 5262|2022-02-17 17:34:15.168471| MAIN > Skip threshold: MIN COMMAND 3.75000e-05
idl_ctrl_86832 |INF| 5263|2022-02-17 17:34:15.168506| MAIN > Skip threshold: MAX FORCE 0.770000
idl_ctrl_86832 |INF| 5264|2022-02-17 17:34:15.168534| MAIN > Skip threshold: MIN FORCE -0.770000
idl_ctrl_86832 |INF| 5265|2022-02-17 17:34:15.177797| MAIN > Settings:
idl_ctrl_86832 |INF| 5266|2022-02-17 17:34:15.177838| MAIN > Skip threshold: MAX DELTA MODE 0.000260000
idl_ctrl_86832 |INF| 5267|2022-02-17 17:34:15.177867| MAIN > Skip threshold: MAX ABS MODE 0.000130000
idl_ctrl_86832 |INF| 5268|2022-02-17 17:34:15.177898| MAIN > Skip threshold: DELTA COMMAND 1.00000e-05
idl_ctrl_86832 |INF| 5269|2022-02-17 17:34:15.177927| MAIN > Skip threshold: MAX COMMAND 7.30000e-05
idl_ctrl_86832 |INF| 5270|2022-02-17 17:34:15.177957| MAIN > Skip threshold: MIN COMMAND 3.75000e-05
idl_ctrl_86832 |INF| 5271|2022-02-17 17:34:15.177985| MAIN > Skip threshold: MAX FORCE 0.770000
idl_ctrl_86832 |INF| 5272|2022-02-17 17:34:15.178012| MAIN > Skip threshold: MIN FORCE -0.770000
idl_ctrl_86832 |INF| 5273|2022-02-17 17:34:15.383108| MAIN > 0
idl_ctrl_86832 |INF| 5274|2022-02-17 17:34:15.383162| MAIN > EndCmd
idl_ctrl_86832 |INF| 5275|2022-02-17 17:34:52.819745| MAIN > Executing command: print,test_demo_mode()
idl_ctrl_86832 |INF| 5276|2022-02-17 17:34:52.819932| MAIN > StartCmd
idl_ctrl_86832 |INF| 5277|2022-02-17 17:34:52.819966| MAIN > IDL license file is running.
idl_ctrl_86832 |INF| 5277|2022-02-17 17:34:52.819966| MAIN > . 0
idl_ctrl_86832 |INF| 5277|2022-02-17 17:34:52.819966| MAIN > . EndCmd
idl_ctrl_86832 |INF| 5278|2022-02-17 17:35:52.820168| MAIN > Executing command: print,test_demo_mode()
idl_ctrl_86832 |INF| 5279|2022-02-17 17:35:52.820349| MAIN > StartCmd
idl_ctrl_86832 |INF| 5280|2022-02-17 17:35:52.820384| MAIN > IDL license file is running.
idl_ctrl_86832 |INF| 5280|2022-02-17 17:35:52.820384| MAIN > . 0
idl_ctrl_86832 |INF| 5280|2022-02-17 17:35:52.820384| MAIN > . EndCmd
idl_ctrl_86832 |INF| 5281|2022-02-17 17:36:52.820596| MAIN > Executing command: print,test_demo_mode()
idl_ctrl_86832 |INF| 5282|2022-02-17 17:36:52.820802| MAIN > StartCmd
idl_ctrl_86832 |INF| 5283|2022-02-17 17:36:52.820867| MAIN > IDL license file is running.
idl_ctrl_86832 |INF| 5283|2022-02-17 17:36:52.820867| MAIN > . 0
idl_ctrl_86832 |INF| 5283|2022-02-17 17:36:52.820867| MAIN > . EndCmd

10:44am stop LN.

11:00 am continous with SOULSX.

Error in the Argos Cal unit.

Gustavo checking...

argoscalun it_20220217.png

Reset in the Status tag a couple of times.

deploy argos cal unit.

11:10 am power up WFS.

Still refilling LBTI. Lights chamber on.

test preset.

Thu Feb 17 18:16:13.773 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1392] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 17 18:16:13.791 2022 aos.info - WFS source set to: FLAOWFS

dl_ctrl_86832 |INF| 5455|2022-02-17 18:16:13.826929| MAIN > Executing command: set_z0, [0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9], KL="tmp", /ZERNIKE, /LUCI
idl_ctrl_86832 |INF| 5456|2022-02-17 18:16:13.827023| MAIN > StartCmd
idl_ctrl_86832 |INF| 5457|2022-02-17 18:16:13.827170| MAIN > EndCmd
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > % RESTORE: Error opening file. Unit: 100
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > . File: /local/aomeas/adsec_calib/M2C/tmp/klmatrix_phase_inv.sav
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > . No such file or directory
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > . % Error occurred at: Z2M4ADSEC 44
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > . /home/aoeng/live/aoroot/idl/adsec_lib/adsec_utilities/z2m4adsec.pro
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > . % SET_Z0 31
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > . /home/aoeng/live/aoroot/idl/adsec_lib/adsec_utilities/set_z0.pro
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > . % $MAIN$
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > . % Execution halted at: $MAIN$
idl_ctrl_86832 |INF| 5458|2022-02-17 18:16:13.827204| MAIN > .
idl_ctrl_86832 |INF| 5459|2022-02-17 18:16:52.838495| MAIN > Executing command: print,test_demo_mode()
idl_ctrl_86832 |INF| 5460|2022-02-17 18:16:52.838662| MAIN > StartCmd

Thu Feb 17 18:19:24.588 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1393] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 17 18:1

dl_ctrl_86832 |INF| 5505|2022-02-17 18:19:24.621298| MAIN > Executing command: set_z0, [0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9], KL="KL_v20", /ZERNIKE, /LUCI
idl_ctrl_86832 |INF| 5506|2022-02-17 18:19:24.621464| MAIN > StartCmd
idl_ctrl_86832 |INF| 5507|2022-02-17 18:19:24.630976| MAIN > EndCmd
idl_ctrl_86832 |INF| 5508|2022-02-17 18:19:24.631007| MAIN > % Program caused arithmetic error: Floating illegal operand
idl_ctrl_86832 |INF| 5508|2022-02-17 18:19:24.631007| MAIN > . % Detected at Z2M4ADSEC 99 /home/aoeng/live/aoroot/idl/adsec_lib/adsec
idl_ctrl_86832 |INF| 5508|2022-02-17 18:19:24.631007| MAIN > . _utilities/z2m4adsec.pro
idl_ctrl_86832 |INF| 5508|2022-02-17 18:19:24.631007| MAIN > .
idl_ctrl_86832 |INF| 5509|2022-02-17 18:19:24.633476| MAIN > Executing command: set_z0, [0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9,0.00e-9], KL="KL_v20", /ZERNIKE, /LUCI
idl_ctrl_86832 |INF| 5510|2022-02-17 18:19:24.633533| MAIN > StartCmd
idl_ctrl_86832 |INF| 5511|2022-02-17 18:19:24.642693| MAIN > EndCmd
idl_ctrl_86832 |INF| 5512|2022-02-17 18:19:24.642719| MAIN > % Program caused arithmetic error: Floating illegal operand
idl_ctrl_86832 |INF| 5512|2022-02-17 18:19:24.642719| MAIN > . % Detected at Z2M4ADSEC 99 /home/aoeng/live/aoroot/idl/adsec_lib/adsec
idl_ctrl_86832 |INF| 5512|2022-02-17 18:19:24.642719| MAIN > . _utilities/z2m4adsec.pro
idl_ctrl_86832 |INF| 5512|2022-02-17 18:19:24.642719| MAIN > .

Filling LBTI..

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 17 18:27:12.171 2022 aos.info - WFS source set to: FLAOWFS
Thu Feb 17 18:27:12.234 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Thu Feb 17 18:27:13.242 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

skip frame close the loop.

Check the focal station,..it was kept to the back (LN).

Set Front from the Adsec contriol gui.

Optimize gain:

failed

last gain:

idl_ctrl_86832 |INF| 6807|2022-02-17 18:49:56.242717| MAIN > EndCmd
idl_ctrl_86832 |INF| 6808|2022-02-17 18:49:56.315790| MAIN > Executing command: print, fsm_set_gain('/local/aomeas/adsec_calib/M2C/KL_v20/gain/g_tt_13.75_ho1_0.10_ho2_0.10.fits')
idl_ctrl_86832 |INF| 6809|2022-02-17 18:49:56.315827| MAIN >
idl_ctrl_86832 |INF| 6810|2022-02-17 18:49:56.315888| MAIN > StartCmd
idl_ctrl_86832 |INF| 6811|2022-02-17 18:49:56.315909| MAIN >
idl_ctrl_86832 |INF| 6812|2022-02-17 18:49:56.325735| MAIN > 0
idl_ctrl_86832 |INF| 6813|2022-02-17 18:49:56.325773| MAIN > % READFITS: Now reading 672 element array
idl_ctrl_86832 |INF| 6813|2022-02-17 18:49:56.325773| MAIN > .
idl_ctrl_86832 |INF| 6814|2022-02-17 18:49:56.325815| MAIN > EndCmd

11:54 adsc_stop/start

flat 637 modes.

Thu Feb 17 18:57:03.370 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1399] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 17 18:57:03.386 2022 aos.info - WFS source set to: FLAOWFS

Thu Feb 17 18:58:28.672 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1400] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize

GOPT.

slope rms:0.45

No disturbance

TN:20220217_190522

luci issue to save the images. email to Dave.

TN:_190844

saving data during a drop in the SR.

_191035

The pupils are jmping around, vibrations .

Telescope is moving in AZ to clear the ice in the base...

Reason of the extra virations.

Thu Feb 17 19:14:42.207 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1404] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

wfsarbitrator off/on.

disturbance not loaded.in the AOS but it is loaded in the Adsec.

Visible the disturbance running in the OCAM viewer.

optimize

3.26,0.74,0.69

gopt

tn+Luci:_192511,_192647

optimize

skip frames second pass.

telesscope still moving..

2.0,0.67,0.66

193453,

ncpa on

_193639,_193749

psf_20220217_193639_ncpaon.png

move to 360

hu Feb 17 19:40:15.214 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1414] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

disturbance running.

optimize

skip frame ho1.

3.3,0.76,0.59

tn:_194737,_

skip frames 73#

during saving telemetry

set gain0.1_10modi

still skipping

save data for catch the forces..+-0.6..??

_195136

Thu Feb 17 19:53:46.685 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1418] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

AOs stuck in the presetAO step...

shell rest.

Restart AO arbitrator.

Thu Feb 17 19:59:42.508 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1419] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize.

no ncpa

_200431,_200541

ncpa on

_200729,_200826

ncpa off.

_201004,_201109

ncpa on

_201221,_201325

rot 380.

ncpa off

optimize gain

_larger oscillation of the gains HO2 than 360.

optimize_rot380_20220217.png

no NCPA: _201805,_201913

NCPA:_202023,_202133

rot 320

no NCPA

optimize

skip frames

3.3,0.76,0.63

_202752,_202852

ncpa

_203028,_203134

skip frames.

100%loop open ?

Bin3 low end

mag 16.2

Thu Feb 17 20:34:38.858 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1423] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

stuck the AOS again in running..

Thu Feb 17 20:36:24.896 2022 aos.info - WFS source set to: FLAOWFS
Thu Feb 17 20:36:44.886 2022 aos.info - Updated variable AOARB.L.LAB_MODE: 0
Thu Feb 17 20:36:44.902 2022 aos.info - AO loop opened, Sound=leftAOOPENED.wav
Thu Feb 17 20:36:44.923 2022 aos.info - Updated variable AOARB.L.SL_READY: 1
Thu Feb 17 20:36:44.940 2022 aos.info - Updated variable AOARB.L.AO_READY: 0

restart the AOS process.

shutter: 48

no disturbance

optimize

2.57,0.82,0.10

rms:1.78

noNcpa

_204548,_204656

5802SR:75

ncpa

_204803,_204946

loaded disturbance.

hu Feb 17 20:52:21.787 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1433] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize.

4.13,3.41,0.10

bin3_optimize_20220217.png

_205802

the residual wavefront:(TT, tot w/o TT): 206.040, 106.470

start to skip

track number during the skip _205910

?

reduce the gain to 0.1 and still skipping... 70%...

stopao

Thu Feb 17 21:01:44.947 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1437] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize.

skip frames..

after the optimize gain is still skipping; 11%

_210640

stop/start adsec

No disturbance

Thu Feb 17 21:14:16.632 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1439] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize

2.57,0.79,0.10

no issues...

211946,

gopt

_212141,_212256

ncpa

_212410,_212514

stop AO.

Table of TN

TN modal SR SR ROT seeing ncpa note

20220217_190844

_191035

87   340 clear OFF no luci image
_192511, 87 76 340 1" OFF 20220218.0006-15
_192647 87   340 1" OFF 17.
_193453 84   340 1" OFF  
_193639 84   340 1" ON  
_200431 84 85 360 1 off  
_200729 84 86 360 1 on  
             

luci

MJD-OBS = 59627.809385 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:30.8927' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0006.fits'
MJD-OBS = 59627.809414 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:33.3957' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0007.fits'
MJD-OBS = 59627.809443 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:35.8994' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0008.fits'
MJD-OBS = 59627.809472 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:38.4024' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0009.fits'
MJD-OBS = 59627.809501 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:40.9055' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0010.fits'
MJD-OBS = 59627.80953 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:43.4085' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0011.fits'
MJD-OBS = 59627.809559 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:45.9115' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0012.fits'
MJD-OBS = 59627.809588 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:48.4146' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0013.fits'
MJD-OBS = 59627.809617 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:50.9176' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0014.fits'
MJD-OBS = 59627.809646 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:25:53.4207' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.0015.fits'
MJD-OBS = 59627.810081 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:26:30.9829' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5016.fits'
MJD-OBS = 59627.810393 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:26:57.9605' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5017.fits'
MJD-OBS = 59627.816074 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:35:08.8188' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5018.fits'
MJD-OBS = 59627.817225 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:36:48.2167' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5019.fits'
MJD-OBS = 59627.818035 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:37:58.2472' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5020.fits'
MJD-OBS = 59627.824909 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:47:52.1194' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5021.fits'
MJD-OBS = 59627.825586 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:48:50.6597' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5022.fits'
MJD-OBS = 59627.82766 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T19:51:49.8612' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5023.fits'
MJD-OBS = 59627.836636 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:04:45.3625' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5024.fits'
MJD-OBS = 59627.837388 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:05:50.3192' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5025.fits'
MJD-OBS = 59627.838644 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:07:38.8105' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5026.fits'
MJD-OBS = 59627.839328 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:08:37.8998' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5027.fits'
MJD-OBS = 59627.840454 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:10:15.2492' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5028.fits'
MJD-OBS = 59627.841189 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:11:18.6908' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5029.fits'
MJD-OBS = 59627.842021 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:12:30.5969' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5030.fits'
MJD-OBS = 59627.842753 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:13:33.8502' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5031.fits'
MJD-OBS = 59627.846063 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:18:19.8529' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5032.fits'
MJD-OBS = 59627.846798 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:19:23.3661' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5033.fits'
MJD-OBS = 59627.847602 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:20:32.8213' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5034.fits'
MJD-OBS = 59627.848411 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:21:42.6685' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5035.fits'
MJD-OBS = 59627.852792 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:28:01.2712' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5036.fits'
MJD-OBS = 59627.853492 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:29:01.7464' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5037.fits'
MJD-OBS = 59627.854603 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:30:37.7123' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5038.fits'
MJD-OBS = 59627.855373 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:31:44.2079' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5039.fits'
MJD-OBS = 59627.865327 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:46:04.2918' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5040.fits'
MJD-OBS = 59627.866036 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:47:05.5533' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5041.fits'
MJD-OBS = 59627.866827 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:48:13.8569' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5042.fits'
MJD-OBS = 59627.868007 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:49:55.7875' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5043.fits'
MJD-OBS = 59627.873813 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:58:17.4666' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5044.fits'
MJD-OBS = 59627.874535 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T20:59:19.8388' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5045.fits'
MJD-OBS = 59627.879798 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T21:06:54.5714' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5046.fits'
MJD-OBS = 59627.8889 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T21:20:00.9404' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5047.fits'
MJD-OBS = 59627.890165 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T21:21:50.2155' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5048.fits'
MJD-OBS = 59627.891041 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T21:23:05.9755' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5049.fits'
MJD-OBS = 59627.891897 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T21:24:19.9329' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5050.fits'
MJD-OBS = 59627.89268 / [d] Modified Julian Date of DATE-OBS
DATE-OBS= '2022-02-17T21:25:27.5417' / [d] UTC end of first frame read
FILENAME= 'luci1.20220218.5051.fits'
FILENAME= 'mods1b.20220217.0001' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T01:42:03.998' / UTC Date at start of obs
FILENAME= 'mods1b.20220217.0002' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T01:45:06.232' / UTC Date at start of obs
FILENAME= 'mods1r.20220217.0003' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T02:07:17.256' / UTC Date at start of obs
FILENAME= 'mods1r.20220217.001' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T01:42:02.925' / UTC Date at start of obs
FILENAME= 'mods1r.20220217.002' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T01:45:05.289' / UTC Date at start of obs
FILENAME= 'mods2b.20220217.0001' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T01:59:11.642' / UTC Date at start of obs
FILENAME= 'mods2b.20220217.0002' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T02:00:50.941' / UTC Date at start of obs
FILENAME= 'mods2r.20220217.0001' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T01:59:10.877' / UTC Date at start of obs
FILENAME= 'mods2r.20220217.0002' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T02:00:50.129' / UTC Date at start of obs
FILENAME= 'mods2r.20220217.0003' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T02:07:18.164' / UTC Date at start of obs
FILENAME= 'mods2r.20220217.0004' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T02:10:57.590' / UTC Date at start of obs
FILENAME= 'mods2r.20220217.0005' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T03:28:21.285' / UTC Date at start of obs
FILENAME= 'mods2r.20220217.0006' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T03:56:52.921' / UTC Date at start of obs
FILENAME= 'mods2r.20220217.0007' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T04:00:41.158' / UTC Date at start of obs
FILENAME= 'mods2r.20220217.0008' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T04:01:58.102' / UTC Date at start of obs
FILENAME= 'mods2r.20220217.0009' / Filename assigned by the data-taking system
DATE-OBS= '2022-02-17T04:05:00.562' / UTC Date at start of obs

-- JuanCarlosGuerra - 17 Feb 2022
Topic revision: r2 - 18 Feb 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback