00:45 Josh gets the WFS power on and starts cooling the OCAM

01:50 Bin 1 OCSO had a failed optimize gain. Set gains manually.
  • see a bit of high forces at 9:00.
  • Move re-rotator +1 degree. a few skip frames.
  • Move re-rotator -1 degree. Many skip frame
  • Move to +0.3 and seems good. I didn't change offset value in wfsarb.conf, small change needed.
  • skip optimize gain
  • Optical gain failed. I still have re-rotator off. Turn it on
  • Optical gain succeed.
  • See some skip frames
  • LUCI waiting for collimation because it took too long to press Done.
  • Move on to IP Tau

02:00 Collimated on nearby Off-axis star
  • Blind AO preset
  • Optimzize gain end and skip frame, loop open
  • Next Opt gain ok, optical gain and NCPA
  • Go to LUCI
  • TN 021218, 022244, 023815, 024838, 025833
  • Bin 2 loop just closed
    bin2_start.jpg
  • High force at actuator 224
    bin2_start_force.jpg
  • After 20 minutes get ring patter in current (scale the same as above)
    bin2_center_rings.jpg
  • Modal plot
    bin2_modal.jpg
  • Later forces on actuator 232
    bin2_later_force.jpg
  • Negative force at actuator 478
    bin2_neg_force.jpg

03:10 Still bin 2 IP Tau
  • Had maybe five minutes where we were getting bursts of skip frames. Up to 70% for 2 seconds and then none of 20 seconds.
  • LUCI images look OK
  • Modal plots look OK
  • TN 031037
  • Now no skip frames

03:13 Loop in PauseAO state.
  • skip frame bar at 100% and Red
at Feb 12 03:13:40.184 2022 aos.info - FLAO: Variable iif.DIMM.elevation is valid
Sat Feb 12 03:13:40.201 2022 aos.info - FLAO: Variable iif.DIMM.R0 is valid
Sat Feb 12 03:13:44.562 2022 aos.OffsetXY{FLAO}.failed - OffsetXY{FLAO}[116] - Command interrupted
Sat Feb 12 03:13:45.644 2022 aos.info - FLAO Alert [ code:177] SkipFrame
Sat Feb 12 03:13:56.235 2022 aos.info - FLAO Alert [ code:177] SkipFrame
Sat Feb 12 03:14:07.782 2022 aos.info - FLAO Alert [ code:177] SkipFrame
Sat Feb 12 03:14:18.141 2022 aos.info - FLAO Alert [ code:177] SkipFrame
Sat Feb 12 03:14:30.589 2022 aos.info - FLAO Alert [ code:177] SkipFrame
Sat Feb 12 03:14:40.949 2022 aos.info - FLAO Alert [ code:177] SkipFrame
Sat Feb 12 03:14:52.538 2022 aos.info - FLAO Alert [ code:177] SkipFrame
Sat Feb 12 03:15:03.191 2022 aos.info - FLAO Alert [ code:177] SkipFrame
  • click ResumeAO on AOS Command GUI
  • Loop Resume, skip frame, StopAO
  • Loop closed again from FLAO GUI
  • Set gains to previous values
  • GOPT on
  • NCPA on
  • Back to taking LUCI images
  • TN 032331, 032611,

03:28 ResumeAO failed because there was no star
at Feb 12 03:28:33.902 2022 aos.OffsetXY{FLAO}.started - OffsetXY{FLAO}[119] (ofsx:-0.0676159[-0.0676159],ofsy:5.32891)
Sat Feb 12 03:28:37.624 2022 aos.OffsetXY{FLAO}.complete - OffsetXY{FLAO}[119]
Sat Feb 12 03:28:38.173 2022 aos.info - HO offload command end
Sat Feb 12 03:28:41.965 2022 aos.Resume{FLAO}.started - Resume{FLAO}[75] 
Sat Feb 12 03:28:42.145 2022 aos.Resume{FLAO}.failed - Resume{FLAO}[75] - [AOException] RETRY: Star not found - loop still paused (-20002) WFSARB_STAR_WRONGFLUX
Sat Feb 12 03:28:45.284 2022 aos.info - FLAO Alert [ code:177] SkipFrame
Sat Feb 12 03:28:55.774 2022 aos.info - FLAO Alert [ code:177] SkipFrame

WfsArbitrator_169439|DEB|      1719|2022-02-12 03:28:33.787809|             MAIN > arbFunc updateNcpaInternal done.
WfsArbitrator_169439|DEB|      1720|2022-02-12 03:28:33.915010|             MAIN > arbFunc offsetXYinternal (, 'FLAOWFS', 'LUCIFER', 0.067615900000000007, 5.3289099999999996, True)
WfsArbitrator_169439|INF|      1721|2022-02-12 03:28:33.915263|             MAIN > offsetXY(): starting offset of 0.042, 5.329 mm
WfsArbitrator_169439|INF|      1722|2022-02-12 03:28:33.916016|             MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm
WfsArbitrator_169439|INF|      1723|2022-02-12 03:28:37.623853|             MAIN > offsetXY(): done
WfsArbitrator_169439|DEB|      1724|2022-02-12 03:28:37.623925|             MAIN > arbFunc offsetXYinternal done.
WfsArbitrator_169439|DEB|      1725|2022-02-12 03:28:41.987589|             MAIN > arbFunc doResumeLoop (, 'FLAOWFS', 'LUCIFER')
WfsArbitrator_169439|INF|      1726|2022-02-12 03:28:42.104202|             MAIN > Total counts/subap: 2.606402 - framerate: 839.0 - Flux: 20
WfsArbitrator_169439|INF|      1727|2022-02-12 03:28:42.104705|             MAIN > Star magnitude on WFS changed from 13.4 to 17.8
WfsArbitrator_169439|INF|      1728|2022-02-12 03:28:42.104755|             MAIN > resumeLoop not executed - loop still paused
WfsArbitrator_169439|ERR|      1729|2022-02-12 03:28:42.104877|             MAIN > RETRY: Star not found - loop still paused (-20002) WFSARB_STAR_WRONGFLUX
WfsArbitrator_169439|DEB|      1730|2022-02-12 03:28:43.796386|             MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 7.7870799999999996, 0)
WfsArbitrator_169439|DEB|      1731|2022-02-12 03:28:43.826782|             MAIN > arbFunc updateNcpaInternal done.
WfsArbitrator_169439|DEB|      1732|2022-02-12 03:28:53.834968|             MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 7.7868700000000004, 0)
  • Bayside stages at -78.66, -40.07
  • Move them to -78, -53 and see the star
  • re-close loop but skip frame and StopAO
  • Re-close loop and ok
  • Manually set gain
  • Gopt
  • NCPA
  • All is good
  • Start LUCI script
  • Offset to same place (script thinks less than an arcsec but Y stage move 15 mm)
  • No start Resume Fail, etc
  • Do loop closure again
  • Same problem. Olga said it looked like LUCI script did all offset but no images, in just a few seconds) LUCI script problem?
  • Also, earlier a filter change by LUCI would reset image to full frame. Olga had to set to sub frame after every offset.
  • Gave up and send Preset again
  • Seems to be working now.
  • TN 044406, 044453, 044551 (some skip frame, everything looks good

Sat Feb 12 04:58:53.050 2022 aos.info - FLAO Alert [ code:177] SkipFrame Sat Feb 12 04:58:53.775 2022 aos.info - TTF offload command end Sat Feb 12 04:58:56.808 2022 aos.info - HO offload command end Sat Feb 12 04:58:57.481 2022 aos.OffsetXY{FLAO}.failed - OffsetXY {FLAO}[165] - Command interrupted Sat Feb 12 04:59:03.601 2022 aos.info - FLAO Alert [ code:177] SkipFrame Sat Feb 12 04:59:14.192 2022 aos.info - FLAO Alert [ code:177] SkipFrame

OWFS', 'LUCIFER', 7.7611699999999999, 0)
WfsArbitrator_169439|DEB|      3055|2022-02-12 04:58:41.335262|             MAIN > arbFunc updateNcpaInternal done.
WfsArbitrator_169439|DEB|      3056|2022-02-12 04:58:49.906559|             MAIN > arbFunc doPauseLoop (, 'FLAOWFS', 'LUCIFER')
WfsArbitrator_169439|INF|      3057|2022-02-12 04:58:50.017878|             MAIN > Total counts/subap: 136.250762 - framerate: 847.0 - Flux: 1105
WfsArbitrator_169439|DEB|      3058|2022-02-12 04:58:50.018446|             MAIN > arbFunc doPauseLoop done.
WfsArbitrator_169439|DEB|      3059|2022-02-12 04:58:51.358260|             MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 7.7611100000000004, 0)
WfsArbitrator_169439|DEB|      3060|2022-02-12 04:58:51.391525|             MAIN > arbFunc updateNcpaInternal done.
WfsArbitrator_169439|DEB|      3061|2022-02-12 04:58:52.870934|             MAIN > arbFunc offsetXYinternal (, 'FLAOWFS', 'LUCIFER', -0.025729599999999998, -7.8442299999999996, True)
WfsArbitrator_169439|INF|      3062|2022-02-12 04:58:52.871180|             MAIN > offsetXY(): starting offset of 0.013, -7.844 mm
WfsArbitrator_169439|INF|      3063|2022-02-12 04:58:52.871950|             MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm
WfsArbitrator_169439|INF|      3064|2022-02-12 04:58:57.480906|             MAIN > offsetXY(): done
WfsArbitrator_169439|DEB|      3065|2022-02-12 04:58:57.480982|             MAIN > arbFunc offsetXYinternal done.
WfsArbitrator_169439|DEB|      3066|2022-02-12 04:59:01.399066|             MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 7.7612300000000003, 0)
WfsArbitrator_169439|DEB|      3067|2022-02-12 04:59:01.425382|             MAIN > arbFunc updateNcpaInternal don
  • seems we did not receive a ResumeAO
  • Only off the tip of the pyramid by 0.2 mm
  • Another offset. same thing
  • This time off by 7 mm

05:10 New bin 3 target
  • Loop closed ok
  • Optimize gain only ramp TT and HO1. HO2 ignore (left at 0.1)
  • After Optimize gain I set HO2 to a little below HO1
  • slope RMS seemed to get a bit smaller
  • Ask Enrico and Alfio
  • bin3_optimize_gain.jpg:
    bin3_optimize_gain.jpg
05:51
  • Greg has taken over.
05:58
  • adsec in failure after trying to re-close the loop.
  • Re-sending.
  • adsec kept failing
  • Guido came on and we determined that actuator 486 was reading 35 microns when the shell was set.
  • We removed it forthwith.
  • Changing to seeing limited.

-- DougMiller - 12 Feb 2022
I Attachment Action Size Date Who Comment
bin2_center_rings.jpgjpg bin2_center_rings.jpg manage 232 K 12 Feb 2022 - 03:00 DougMiller  
bin2_later_force.jpgjpg bin2_later_force.jpg manage 214 K 12 Feb 2022 - 03:01 DougMiller  
bin2_modal.jpgjpg bin2_modal.jpg manage 60 K 12 Feb 2022 - 03:01 DougMiller  
bin2_neg_force.jpgjpg bin2_neg_force.jpg manage 254 K 12 Feb 2022 - 03:01 DougMiller  
bin2_start.jpgjpg bin2_start.jpg manage 234 K 12 Feb 2022 - 03:00 DougMiller  
bin2_start_force.jpgjpg bin2_start_force.jpg manage 231 K 12 Feb 2022 - 03:00 DougMiller  
bin3_optimize_gain.jpgjpg bin3_optimize_gain.jpg manage 107 K 12 Feb 2022 - 05:48 DougMiller  
Topic revision: r4 - 12 Feb 2022, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback