Details

Telescope released at 11:45 AM

Power up WFS.

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 10 19:00:31.666 2022 aos.info - WFS source set to: FLAOWFS
Thu Feb 10 19:00:31.749 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Thu Feb 10 19:00:32.914 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

check pupil drived the spot out... shows like a wrong spot.

The spot is again checked with the CCD47 and it is in the right place.

To have a clear start

Power off WFS and Adsec.

12:18 PM

Adsec_stop/start

w_stop/start

145531 |INF| 183|2022-02-10 19:19:01.725745| MAIN > housekeeper.L test started.
AdSecArbitrator_145631|WAR| 89|2022-02-10 19:19:10.077198| MAIN > Skip frame detected!
Last message repeated
AdSecArbitrator_145631|ERR| 90|2022-02-10 19:19:11.077421| FASTDIAGN > [AOException] Error (Timeout error) in GetDiagnValue [2] (code -5001) Timeout error
idl_145531 |INF| 184|2022-02-10 19:19:12.729206| MAIN > housekeeper.L non yet started or giving wrong reading in the CHECK DEW POINT variable (Nan, Inf, >200 deg or <0).
idl_145531 |INF| 185|2022-02-10 19:19:24.732288| MAIN > housekeeper.L test done.
idl_145531 |INF| 186|2022-02-10 19:19:24.732334| MAIN > Set thresholds for check dew point variable: ALARM: 0, Inf C Deg
idl_145531 |INF| 187|2022-02-10 19:19:24.732352| MAIN > Set thresholds for check dew point variable: WARINING: 2, 50 C Deg
idl_145531 |INF| 188|2022-02-10 19:19:29.741573| MAIN > fsm_reset() procedure done.
AdSecArbitrator_145631|INF| 100|2022-02-10 19:19:29.745471| COMMANDHANDLER > Command Power on (code 2004) successfully completed
Last message repeated
idl_145531 |INF| 189|2022-02-10 19:19:29.745228| MAIN > fsm_power_on() command done.
AdSecArbitrator_145631|ERR| 101|2022-02-10 19:19:31.112074| FASTDIAGN > [AOException] Error (Timeout error) in GetDiagnValue [2] (code -5001) Timeout error

load program

AdSecArbitrator_145631|INF| 121|2022-02-10 19:20:47.661593| COMMANDHANDLER > Command Load program (code 2006) successfully completed
Last message repeated
20221002 19:21:07.6032

19:22:45.775466| MAIN > Maximum mode index used to apply flat -> # 638

Power on WFS

homing pupil rerotator.

moving negative to find the limit.

stop/start again

Start homing

find the limit

move to 10 degrees

homing.

find the homing

ocam good frames

Thu Feb 10 19:35:00.812 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[25] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 10 19:35:00.826 2022 aos.info - WFS source set to: FLAOWFS
Thu Feb 10 19:35:00.874 2022 aos.info - FLAO: WARNING: added

TN:_20220210_193618

homing the AGW1.

The vignetting come from that device. The AGW1 was tested.

optimize gain

a few skip frames

3.97,0.76,0.67

TN: 20220210_201304,_201459,_201628

frames same as yesterday.

modalplot

frames_20220210_201304.png

modalplot_20220210_201628.png

psf_20220210_201628.png

the residual

20220210_201459 CL res (TT, tot w/o TT): 289.931, 143.570

20220210_201628 CL res (TT, tot w/o TT): 124.731, 135.914

Thu Feb 10 20:22:29.342 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[29] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 10 20:22:29.360 2022 aos.info - WFS source set to: FLAOWFS
Thu Feb 10 20:22:29.433 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits

optimize gain:

3.24,0.76,0.59

a few skip frames.

TN: _202830,_203033,_203159

good corrections

20220210_202830 CL res (TT, tot w/o TT): 135.181, 129.006

20220210_203033 CL res (TT, tot w/o TT): 167.514, 136.318

20220210_203159 CL res (TT, tot w/o TT): 228.189, 142.056

SR 80%

pupil wobble bin4

Thu Feb 10 20:36:23.190 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[34] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.8,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 10 20:36:23.204 2022 aos.info - WFS source set to: FLAOWF

start 1:46

good.

end:2:02

bin4_wobble_20220210.png

-- JuanCarlosGuerra - 10 Feb 2022
Topic revision: r1 - 10 Feb 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback