Summary.

WFS was left power on from daybefore.

The wfsarb has the change in offset rotaotr to 350.6 and the home speed to 0.5

Details.

Statup

9:15am call from the mountain, the telescope can be use for SoulSX.

loaded turbulence 1" seeing

O,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Wed Feb 9 16:40:31.687 2022 aos.info - WFS source set to: FLAOWFS
Wed Feb 9 16:40:31.730 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Wed Feb 9 16:40:32.628 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

Rotation tracking on

Position: 180.103

optimize gain:

3.61,0.9,gopt

1.46,0.37,0.3

TN: 20220209_165316

TN+Luci:_165353.

frame20220209_165353.png

modakplot_20220209_165353.png

Residual wavefront rms: 141.548, 132.616

SR:75%

psf_20220209_165353.png

pause/init/resume/wait 5sec.

TN+Luci:_170049,_170358

TT, tot w/o TT,SR = 126.385, 141.402,73

_170819

TT, tot w/o TT,SR = 137.082, 134.022,74

pause/init/resume/wait 5sec.

Wed Feb 9 17:20:43.430 2022 aos.Resume{FLAO}.complete - Resume{FLAO}[574]
Wed Feb 9 17:20:44.274 2022 aos.info - TTF offload: previous 2 requests ignored
Wed Feb 9 17:20:44.291 2022 aos.info - TTF Offload request (FLAO) Z: 0.0505572 -0.0732356 0.000175556

TN:_172057,_172336

TT, tot w/o TT,SR = 277.533, 137.463, 74

TT, tot w/o TT,SR = 192.831, 134.204, 73

pause/init/resume/wait 5sec

ocam_frames_10_36.png

TN:_173116,_173335,_173559,_173841.

residual wavefront rms:

TT,tot wo tt,SR = 121,123.9,75

TT,tot wo tt,SR = 150,129.2,75

TT,tot wo tt,SR = 123,122,76

TT,tot wo tt,SR = 289,151,76

frame-20220209_173116.png frame-20220209_173841.png

setPSF_173116to173841.png

pause/init/resume/wait 5sec.


Wed Feb 9 17:46:05.100 2022 aos.Resume{FLAO}.complete - Resume{FLAO}[574]
Wed Feb 9 17:46:05.765 2022 aos.info - TTF Offload request (FLAO) Z: 0.0229349 0.252414 -0.000864045
Wed Feb 9 17:46:08.709 2022 aos.info - TTF offload command end
Wed Feb 9 17:46:08.765 2022 aos.info - TTF offload: previous 2 requests ignored

_174639,_174838,_175044.

this set is open loop images.(?)

stop 10:55 am

Alessandro access to the telescope and possible tip to horizone.

back: 12:39 PM

Wed Feb 9 19:53:38.109 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[593] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Wed Feb 9 19:53:38.121 2022 aos.info - WFS source set to: FLAOWFS
Wed Feb 9 19:53:38.167 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Wed Feb 9 19:53:38.913 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

optimize gain

3.30,0.81,0.26

tn:_200314,_200525,_200729

(TT, tot w/o TT, SR: 133.730, 125.086, 72

(TT, tot w/o TT),SR 129.698, 141.517, 70

(TT, tot w/o TT,SR: 154.516, 125.191, 72

frames-20220209_200314.png frames-20220209_200729.png

pause/init/resume/

Arbitrator_7180|INF| 506|2022-02-09 20:12:26.954049| MAIN > Received cmd: ResumeAo ()
AdSecArbitrator_7180|INF| 507|2022-02-09 20:12:26.954124| COMMANDHANDLER > FSM (status: AOPause) has received command 2028 (ResumeAo Ao)
AdSecArbitrator_7180|INF| 508|2022-02-09 20:12:26.961642| COMMANDHANDLER > Command ResumeAo Ao (code 2028) successfully completed
AdSecArbitrator_7180|INF| 509|2022-02-09 20:12:27.097886| MAIN > Received cmd: Offloading(1)
AdSecArbitrator_7180|INF| 510|2022-02-09 20:12:27.097953| COMMANDHANDLER > FSM (status: AORunning) has received command 2029 (TTOffload)
AdSecArbitrator_7180|INF| 511|2022-02-09 20:12:27.325897| COMMANDHANDLER > Command TTOffload (code 2029) successfully c

201252,_201520,

TT, tot w/o TT, SR = 155.330, 125.975,73

MODALPLOT_204036.png

MODAL_201520.png

no psf in the ocam...

What happen..? to check adsec logs

loop open in the last TN

1:18PM

clear thin shell offset.

Wed Feb 9 20:20:16.604 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[599] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Wed Feb 9 20:20:16.619 2022 aos.info - WFS source set to: FLAOWFS
Wed Feb 9 20:20:16.681 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Wed Feb 9 20:20:17.360 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

The AO still presetAO Running...

The WFS is AO prepared and Adsec AOset.

Launch againthe AOSGI and it doen't come up.

Rest shell.

stop/stat AOS

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Wed Feb 9 20:27:25.644 2022 aos.info - WFS source set to: FLAOWFS
Wed Feb 9 20:27:25.686 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Wed Feb 9 20:27:26.362 2022 aos.info - FLAO: WFS: loading setup for LUC

Wed Feb 9 20:28:31.456 2022 aos.info - FLAO: Adsec 672b-left loading reconstructor.
Wed Feb 9 20:28:34.028 2022 aos.info - AOS tel- adsec_shape_error Collection connected to Telemetry Store

optimize gain

3.55,0.81,0.63

gopt

slope rms:1.4,1.1,1.0

TN:_203346,_203604,_203803

This set of data shows a corrections that it moved to a non corrections, drift.

TT, tot w/o TT, SR = 350.362, 143.062, 70

TT, tot w/o TT, SR = 3525.32, 789.166, 71

TT, tot w/o TT, SR = 497.977, 301.277, 70

psf_set_203346-203803.png

offset 0.2

180.303

rms 0.96

204036,

TT, tot w/o TT: 299.538, 244.090,

bad psf.....

drift ?

Wed Feb 9 20:41:28.791 2022 aos.info - TTF Offload request (FLAO) Z: -0.146654 -0.0357243 6.94496e-05
Wed Feb 9 20:41:31.519 2022 aos.info - TTF offload command end
Wed Feb 9 20:41:31.771 2022 aos.info - TTF offload: previous 2 requests ignored
Wed Feb 9 20:41:31.783 2022 aos.info - TTF Offload request (FLAO) Z: 0.136998 -0.00429812 0.000178598
Wed Feb 9 20:41:35.547 2022 aos.info - TTF offload command end

handover. 1:50 PM

-- JuanCarlosGuerra - 09 Feb 2022
I Attachment Action Size Date Who Comment
MODALPLOT_204036.pngpng MODALPLOT_204036.png manage 19 K 09 Feb 2022 - 22:50 JuanCarlosGuerra  
MODAL_201520.pngpng MODAL_201520.png manage 19 K 09 Feb 2022 - 22:52 JuanCarlosGuerra  
bad_psf_204036.pngpng bad_psf_204036.png manage 46 K 09 Feb 2022 - 22:46 JuanCarlosGuerra  
frame-20220209_173116.pngpng frame-20220209_173116.png manage 48 K 09 Feb 2022 - 18:49 JuanCarlosGuerra  
frame-20220209_173841.pngpng frame-20220209_173841.png manage 47 K 09 Feb 2022 - 18:49 JuanCarlosGuerra  
frame20220209_165353.pngpng frame20220209_165353.png manage 46 K 09 Feb 2022 - 18:51 JuanCarlosGuerra  
frames-20220209_200314.pngpng frames-20220209_200314.png manage 71 K 09 Feb 2022 - 22:34 JuanCarlosGuerra  
frames-20220209_200729.pngpng frames-20220209_200729.png manage 87 K 09 Feb 2022 - 22:35 JuanCarlosGuerra  
modakplot_20220209_165353.pngpng modakplot_20220209_165353.png manage 54 K 09 Feb 2022 - 16:59 JuanCarlosGuerra  
ocam_frames_10_36.pngpng ocam_frames_10_36.png manage 117 K 09 Feb 2022 - 17:36 JuanCarlosGuerra  
psf_20220209_165353.pngpng psf_20220209_165353.png manage 40 K 09 Feb 2022 - 17:02 JuanCarlosGuerra  
psf_set_203346-203803.pngpng psf_set_203346-203803.png manage 114 K 09 Feb 2022 - 22:43 JuanCarlosGuerra  
setPSF_173116to173841.pngpng setPSF_173116to173841.png manage 149 K 09 Feb 2022 - 18:46 JuanCarlosGuerra  
Topic revision: r1 - 09 Feb 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback