Details.

1:40PM

Power on

l1:55 PM uci

initialize_all

set N30 camera.

Tue Feb 8 21:00:19.468 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[509] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

ok.

Loaded with disturbance 1" seeing

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 8 21:11:18.561 2022 aos.info - WFS source set to: FLAOWFS

ue Feb 8 21:11:18.622 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Tue Feb 8 21:11:19.437 2022 aos.info - FLAO: WFS: loadi

optimize gain.

HO1 skip frames to 34%

ho2 skip frames to 20%

2.89,0.93,0.22

TN:20220208_211734

master diagnotic reports many warning messages:

The fastdiagnostic reports many FUNCWARNING messages.

visible a "dent" in the pupils.

frames_20220208-211734.png

The PSF

loop pause

current position:179.102

stop pupil tacking.

delta position of +0.2

TN:_212727

frames_20220208_212727.png

delta of:0.4

179.802

TN:_213054

residual wavefront rms: 462.641, 173.748

delta:0.6

180.402

TN:_213340

residual wavefront rms: 211.956, 148.232

delta:0.8

oscillation visible (fringes)

TN:_213723

TT, tot w/o TT): 647.379, 625.508

Set back the best position: 180.402

TN:_214148

good.

loop pause

init pupil rerotator.

pupil tracking

position:179.102

resume

TN:_214550

visible the "dent"

apply the position 180.402.

TN:_214906

no dent

pause

init

resume

wait 5 sec.

TN:_215311

visble dent.

tracking off

position to 180.402

TN:_215543

no dent.

Stop AO

change homespeed2 to 0.5

device off/on

homing after the power cycle.

homing ok

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 8 22:00:02.718 2022 aos.info - WFS source set to: FLAOWFS
Tue Feb 8 22:00:02.792 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Tue Feb 8 22:00:03.513 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

optimze gain

ho1 skip frames to 72%

2.87,0.74,0.61

gopt.

TN:_220531

better position.

frame_20220208_220531.png

stop rot

position to 180.402

TN:_220846

pause/homing/resume

TN:_221410

377.729, 172.996

delta:0.2

179.302

TN:_221636

better.

TT, tot w/o TT): 361.988, 172.258

delta:0.2

179.502

TN:_221918

236.630, 150.966

delta:0.2

179.702

TN:222306

220.281, 135.407

modal_20220208_222306.png

delta:0.2

179.902

TN:_222654

delta:0.2

180.102

jump in the pupils at the start of the TN

TN:_223017

150.711, 132.529

repeat TN:_223124

delta: 0.2

180.302

TN:_223337

288.660, 154.715

paus/homing/resume

wait 5sec.

TN:_223901

273.095, 206.871

rotaotr to 180.102

TN:_

error saving

TN:_224150 no saved.

restart the process opt loop diagnostic

TN:Saving... but nnot getting..


MasterDiagnostic_4163|WAR| 49120|2022-02-08 22:46:58.247251| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 901 (instead of packetId 8 for frameId 897)
MasterDiagnostic_4163|WAR| 49121|2022-02-08 22:46:58.247317| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_4163|WAR| 49122|2022-02-08 22:46:58.247389| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 901 (instead of packetId 0 for frameId 901)
MasterDiagnostic_4163|WAR| 49123|2022-02-08 22:46:58.247414| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_4163|WAR| 49124|2022-02-08 22:46:58.247473| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 901 (instead of packetId 0 for frameId 901)
MasterDiagnostic_4163|WAR| 49125|2022-02-08 22:46:58.247493| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_4163|WAR| 49126|2022-02-08 22:46:58.907129| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 3 for frameId 618 (instead of packetId 5 for frameId 603)
MasterDiagnostic_4163|WAR| 49127|2022-02-08 22:46:58.907190| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_4163|WAR| 49128|2022-02-08 22:46:58.907260| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 4 for frameId 618 (instead of packetId 0 for frameId 618)
MasterDiagnostic_4163|WAR| 49129|2022-02-08 22:46:58.907283| ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 599 (instead of packetId 1 for frameId 595)
MasterDiagnostic_4163|WAR| 49130|2022-02-08 22:46:58.907324| ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_4163|WAR| 49131|2022-02-08 22:46:58.907291| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_4163|WAR| 49132|2022-02-08 22:46:58.907371| ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 599 (instead of packetId 0 for frameId 599)
MasterDiagnostic_4163|WAR| 49133|2022-02-08 22:46:58.907385| ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_4163|WAR| 49134|2022-02-08 22:46:58.907413| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 5 for frameId 618 (instead of packetId 0 for frameId 618)
MasterDiagnostic_4163|WAR| 49135|2022-02-08 22:46:58.907436| BCU39 > FramesDownloader BCU39: packet successfully ignored !
Maste

handover 3:52PM

-- JuanCarlosGuerra - 08 Feb 2022
Topic revision: r2 - 09 Feb 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.