Staff:

LBTO: Juan Carlos

summary.

system check for night time today (second half).

Details

Not too much time left afte rLBTI hand over (2:30PM).

It was perform a close check for Bin1, that results in a good corrections,. The pupil woibble were checked for Bin1 and Bin3 and it is still in range there is not changes in the amplitude.

The optimze gain for Bin3 faint case does two iteration in the optimize gain (as expected.).

More time required for the pupil rerotator data acquisiton for different home speed. Requested time for tomorrow and Wedesnday.

power on

timeout.

|ERR| 52|2022-02-07 20:41:37.346057| MAIN > Exception: Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR
WfsArbitrator _137738|ERR| 53|2022-02-07 20:41:37.346109| MAIN > Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR (-1000) GENERIC_SYS_ERROR

WfsArbitrator _137738|ERR| 117|2022-02-07 20:49:13.244676| MAIN > Exception: Timeout waiting for baysidex.L.STATUS
WfsArbitrator_137738|ERR| 118|2022-02-07 20:49:13.244735| MAIN > Timeout waiting for baysidex.L.STATUS (-5001) TIMEOUT_ERROR
WfsArbitrator_137738|DEB| 119|2022-02-07 20:49:13.245076| MAIN > arbFunc updateModulationInternal (, 'FLAOWFS', '', 2000)

power cycle stage.

OK

Power on

FAILED TIMEOUT.

TRIED A SECOND TIME FAILED.

W_STOP/START_ALL

POWER ON

OK

TEST PRESET.

Mon Feb 7 21:20:03.232 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[238] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Feb 7 21:20:03.247 2022 aos.info - WFS source set to: FLAOWFS
Mon Feb 7 21:20:04.318 2022 aos.info - FLAO: WFS: loading setup for LUCIFE

CENTER PUPIL REPORTED AND ERROR.

Temperature of camera lens.

WfsArbitrator _176246|DEB| 203|2022-02-07 21:28:25.272433| MAIN > arbFunc doCenterPupils (, 'FLAOWFS', 'LUCIFER')
WfsArbitrator _176246|ERR| 204|2022-02-07 21:28:25.273526| MAIN > RETRY: Camera lens temperature too low. T= 4.19, minimum allowed is 7.00 (0) NO_ERROR

This error should or warning should be catch up the beginning of the power up.

waiting to have the temperature of the box47 goes to 7C

power on LFBG error.

Mon Feb 7 21:54:54.347 2022 LFBG Rotator: received rcReady command. result = 'ERROR rotator is faulted or busy turning on or off.'
Mon Feb 7 21:55:03.967 2022 LFBG RotatorSM: Machine::setStateNumber changed from R_WAIT_RESET to R_IDLE

power off/on

ok

wobble check

2:57PM start.

ok for bin1

bin1_20220207.png

bin3 forward.

start 3:27PM

bin3-20220207.png

checkAO disturbance on.

Bin1

on Feb 7 22:35:43.356 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[245] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Feb 7 22:35:43.370 2022 aos.info - WFS source set to: FLAOWFS
Mon Feb 7 22:35:43.436 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Mon Feb 7 22:35:44.200 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

optimize gain

ok

gopt

ok

bin1_optimizegain_20220207.png

TN:20220107_224113,_224129

bin3 faint.

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Feb 7 22:43:06.863 2022 aos.info - WFS source set to: FLAOWFS
Mon Feb 7 22:43:06.920 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq200.0000_sd3892.fits

optimize gain


WfsArbitrator_176246|INF| 779|2022-02-07 22:46:03.364925| MAIN > Starting autogain, TN=20220207_224603
WfsArbitrator_176246|INF| 780|2022-02-07 22:46:03.379065| MAIN > TT: range 0.05 - 8.10
WfsArbitrator_176246|INF| 781|2022-02-07 22:46:15.268388| MAIN > TT optimization completed: found a good minimum ( 4.66)
WfsArbitrator_176246|INF| 782|2022-02-07 22:46:15.268467| MAIN > HO1: range 0.05 - 4.10
WfsArbitrator_176246|INF| 783|2022-02-07 22:46:27.340662| MAIN > HO minimum was not deep enough, forcing iteration (threshold is 0.850000)
WfsArbitrator_176246|INF| 784|2022-02-07 22:46:33.850761| MAIN > HO minimum was not deep enough, forcing iteration (threshold is 0.850000)
WfsArbitrator_176246|INF| 785|2022-02-07 22:46:43.766962| MAIN > HO minimum was not deep enough, forcing iteration (threshold is 0.850000)
WfsArbitrator_176246|INF| 786|2022-02-07 22:46:58.051972| MAIN > HO1 optimization completed: found a good minimum ( 2.90)
WfsArbitrator_176246|INF| 787|2022-02-07 22:46:58.052073| MAIN > TT: range 0.05 - 8.10
WfsArbitrator_176246|INF| 788|2022-02-07 22:47:10.012077| MAIN > TT optimization completed: found a good minimum ( 5.02)
WfsArbitrator_176246|DEB| 789|2022-02-07 22:47:10.032148| MAIN > getSetupFits(): fits header created

gopt

0.6,0.35,0.03

TN:_224802,_224835

bin3_faint_optimizegain_20220207.png

handover 3:57PM

-- JuanCarlosGuerra - 07 Feb 2022