Staff:

LBTO: Greg, Juan Carlos

Summary.

Telescope not released for SoulSX tests.

Power up the soulSX wfs and build a reconstructor for 400 modes.

Details.

Power up.

  • ocam frames good.
Running intmatAnalyseGui.

First run, I've lost the connection with X2Go and the Gui were clean up the gui.

launch again the Guis.

launch the intmatAnalyseGui.

The process at the end get stuck.

Checking the adsec directory for the Rec. The file is saved.

-rw-rw-r--. 1 AOeng aoeng 10500 Jan 25 17:45 Intmat_20220125_174333.fits_saturation.sav
-rw-rw-r--. 1 AOeng aoeng 10500 Jan 25 18:00 Intmat_20220125_175858.fits_saturation.sav
-rw-rw-r--. 1 AOeng aoeng 4576320 Jan 25 18:04 Intmat_20220125_175858.fits
-rw-rw-r--. 1 AOeng aoeng 18696 Jan 25 18:04 Intmat_20220125_175858.fits_data.sav
-rw-rw-r--. 1 AOeng aoeng 8028 Jan 25 18:05 Intmat_20220125_175858.fits_svd.png
-rw-rw-r--. 1 AOeng aoeng 7675200 Jan 25 18:08 Rec_20220125_175858.fits

Check the file in the adsec gui shows the same configuraiton than the default rec for bin1 500modes.

Telescope busy and later release from LBTI. No close loop check.

Task for tomorrow

-- JuanCarlosGuerra - 25 Jan 2022