LBTO Staff.

Juan Carlos

Doug.

Summary.

close check. Follow up the daytime checks where some oscillation where observed in the PSF.

Details.

Set flat

638 modes.

operate

timeout.

WfsArbitrator _139221|DEB| 127|2022-01-20 06:08:32.766681| MAIN > arbFunc updateModulationInternal (, 'FLAOWFS', '', 1000)
WfsArbitrator_139221|INF| 128|2022-01-20 06:08:32.767680| MAIN > Setting tiptilt to amp= 0.00, freq= 0.00, offx= 0.00, offy= 0.00
WfsArbitrator_139221|DEB| 129|2022-01-20 06:08:32.768008| MAIN > arbFunc updat

retry operate.

WfsArbitrator _139221|INF| 188|2022-01-20 06:11:45.458452| MAIN > Setting up rerotator
WfsArbitrator_139221|INF| 189|2022-01-20 06:11:45.458599| MAIN > Turning on REROT_POWER
WfsArbitrator_139221|INF| 190|2022-01-20 06:13:45.459378| MAIN > Timeout waiting for rerotator.L.STATUS - TIMEOUT_ERROR
WfsArbitrator_139221|ERR| 191|2022-01-20 06:13:45.459472| MAIN > Exception: Timeout waiting for rerotator.L.STATUS
WfsArbitrator_139221|ERR| 192|2022-01-20 06:13:45.459524| MAIN > Timeout waiting for rerotator.L.STATUS (-5001) TIMEOUT_ERROR

it is continlus moving....

change homespeed2 to 1.0

power on pupil rerotator.

Restart the system

w_stop_all,w_start_all.

Operate.

The pupil rerotator homed.

Bin 1

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Thu Jan 20 06:36:02.914 2022 aos.info - WFS source set to: FLAOWFS
Thu Jan 20 06:36:02.991 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Thu Jan 20 06:36:04.175 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

center pupil failed.

Ocam not live.

power cycle bcu2k

The masterdiagnostic process went down.

back to live.

optimize: 2.04,0.59,0.58

rms:0.5

gopt:

rms:0.6

tn:20220120_064842

luci1.20220120.0013

ncpa on

tn:_065022

luci.0014

psf_20220120_065022.png

Adsec to FAILURE ...

load program

idl_5101 |INF| 704|2022-01-20 06:58:46.722143| MAIN > Oversampling frames disabled.
AdSecArbitrator_5204|WAR| 173|2022-01-20 06:58:46.939644| IDL > Syntax error found. Catching...
Last message repeated
20222001 06:58:46.9404 Alert: Warning: loadProgram failed or syntax error occured
AdSecArbitrator_5204|WAR| 174|2022-01-20 06:58:46.940025| IDL > Syntax error successfully catched
AdSecArbitrator_5204|ERR| 175|2022-01-20 06:58:46.940057| IDL > Command returns error : Timeout error
AdSecArbitrator_5204|INF| 176|2022-01-20 06:58:46.940163| COMMANDHANDLER > Command execution failed: Fsm forced to Failure
AdSecArbitrator_5204|ERR| 177|2022-01-20 06:58:46.940184| MAIN > LoadProgram: FATAL - Timeout error
AdSecArbitrator_5204|ERR| 178|2022-01-20 06:58:46.971877| FASTDIAGN > [AOException] Error (Timeout error) in GetDiagnValue [2] (code -5001) Timeout error

It seems the fastdiagnostic didn;t connect... to be investigated...

load program

\ok

set falt

ok

idl_5101 |INF| 1064|2022-01-20 07:01:05.158101| MAIN > Maximum mode index used to apply flat -> # 638

after the restart the AOS doen;t load the disturbance file.

close loop no disturbance

gopt

rms=0.3

tn:_071914

handover to Doug for NCPA

Analysis.

-- JuanCarlosGuerra - 20 Jan 2022
Topic revision: r2 - 20 Jan 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback