LBTO staff:

summary.

The night is call for close dome activities due to the roof conditions and the bad forecast for the night.

LFBG rotator wa repaired and it is in operations.

Use the close dome for pupils wobble checks for all the binnings.

shift for pupil bin 3: 20220119_035330

shift for pupil bin1:2021210_210322

ACE-AO table updated with the pupils files for Bin1 and Bin3.

Details.

Luci in use. Dave Thomson is using the Lucis for checking instruments,

Deploy argos cal unit and power on the WFS.

Starting up at 5PM

LUCI work done at 5:15PM

CHAMBER TEMPERATURE: -4C

BIN1

Wed Jan 19 00:19:24.452 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[618] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Wed Jan 19 00:19:24.466 2022 aos.info - WFS source set to: FLAOWFS

CENTER STAR

OK

CENTER PUPILS

OK

CL: X=53.75, Y=3.13

ROT 341.

STARTING.

CLOSE LOOP MODI_10

TN:20220119_004804

BIN1:

PUPIL:20211125_004613

rec:20190930_161000, default pupil: 20181103_001410

WOBBLE RUN:

UT:20220119-00:55 AM

LT:5:55PM

bin1_20220118.png

BIN2

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

shutter 56

Reconstructor: 20191011_125000 default pupil:

the ocam vierwer shows a bad frame.

bin2_badframe_20220118.png

open loop taking CCD frames.

freq=200Hz.

TN:20220119_013012.

power cycle bcu2k

configure CCD: 1x1 crop

2x2.

check image.

open loop frames

tn:_013423

ok frames.

PUPIL:20211125_011619

CL: X=27.57,Y=0.46 @341

WOBBLE CHECK.

START 6:37PM

BIN2_20220118.png

BIN3

Wed Jan 19 01:57:26.183 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[623] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

shutter: 48

pupil:20211202_185044

camera lens: x=34.9,y=-1.7

there is a mistake in the filtering it is applying the : foregettingfactorBin4SOUL...?

STARTING 7:15PM

rot 341

X=9, y=-16

@320 BAD camera lens tracking, it seems that it was not tracking.

open loop.

move the camera lens, center the pupils again, red circle

it jumped to +100, diff y=-1.8, diffx=-0.55

it requires a shift in X positive of 2 pixels....

rec:20200922_153500, default pupils 20200210_000000

this pupil is not found in the mode4 directory.

BIN3_FAINT_20220118.png


move to bright end of bin3.

Wed Jan 19 02:58:08.325 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[625] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

reconstructor:20200922_150000

default pupil:

working pupil:20211202_185044

saturation positive diff y=-2.2
  • loaded the pupil done with: makePupils.movePupils('20200210_000000',1,1,240,4)
  • '20211202_175957'
rot 341 camera lens from HW x=24,y=-84

move backward.

Saturation of the X negative with an error of 0.6

move forward.

@220 diffy=0.8

bin3_shift_1_1.png

the error is about 0.8

shift.

>>> makePupils.movePupils('20200210_000000',0,1,240,4)
makePupils_fromMasks(): moving from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20220119_033433/pupdata.txt
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20220119_033433/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 148
out_of_pupil_slopes 2552
lines_to_add 11
residual_pixels_to_add 38
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4 to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20220119_033433
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pup1.fits" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20220119_033433"
'20220119_033433'

Loaded the pupil :20211202_185044. which applied x=2,y=1 shift.

apply offset x=2

start 8:45pm

There is saturation but the pupil error is around 0.2 for all the saturaiton range.....

shift of 3 pixels.

>>> makePupils.movePupils('20200210_000000',3,1,240,4)
makePupils_fromMasks(): moving from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20220119_035330/pupdata.txt
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20220119_035330/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 148
out_of_pupil_slopes 2552
lines_to_add 11
residual_pixels_to_add 38
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4 to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20220119_035330
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pup1.fits" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20220119_035330"
'20220119_035330'
>>>

loaded the pupil: 20220119_035330

move forward from 0

ok

move from 360 to 0

ok

bin3_20220118.png

BIN4

Wed Jan 19 05:00:16.552 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[627] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

SHUTTER 46.

ROT@341 X=28, Y=53

PUPIL:20211205_144238

REC:20200923_180000, DEFAULT PUPIL:

BIN4_20220118_OCAM.png

START:10:16PM

bin4_20220118.png

bin3 faint

Wed Jan 19 05:42:13.578 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[633] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

shutter:46

loaded the pupil:20211202_185044

@341 x=22.7, y=-16

bin3_faint-20220118.png

backward 10:50pm

slightly touching he negative X -100

bin3_faint_pass2_20220118.png

loaded the pupil:20220119_035330.

bin3_pass2_pupil20220119_035330_20220118.png

bin1 with a shift.

loaded a pupil '20211210_210322

>>> makePupils.movePupils('20181103_001410',7,10,240,2)
makePupils_fromMasks(): moving from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20211210_210322/pupdata.txt
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20211210_210322/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 1256
out_of_pupil_slopes 336
lines_to_add 2
residual_pixels_to_add 24
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode2 to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20211210_210322
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pup1.fits" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20211210_210322"
'2021210_210322

start 11:56pm

bin1_shifted_20220118.png

check close loop with new bin1 pupil.

modified the table ACE-AO table 20220119.

lrwxrwxrwx. 1 AOeng AOeng 33 Jan 19 07:24 table_LUCIFER_ACE-AO.txt -> table_LUCIFER_ACE-AO.txt.20220119

Wed Jan 19 07:19:27.927 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[637] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

the camera lens was stick at x=100,y=-100.

interrupt command.

move the camera lens manually

center pupil again.

ok

close loop.

TN:20220119_072932.

optimize gain

gopt

tn:-073336

ocst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Wed Jan 19 07:36:24.212 2022 aos.info - WFS source set to: FLAOWFS
Wed Jan 19 07:36:24.277 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

HO1 and HO2 skip frames,.. check for pupil rotation mistmatch...

optimize gain:2.41,0.74,0.32

gopt:1.03,0.32,0.16

TN:_074254,_074557.

bin1_seeing08_modal_20220119.png

bin1-seeing09_gopt_20220119.png

close loop bin4

mag 17

shutter 42

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Wed Jan 19 07:52:29.202 2022 aos.info - WFS source set to: FLAOWFS
Wed Jan 19 07:52:29.265 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits

optimize: 1.18,1.01,0.10

gopt.: 0.24,0.21,0.02

tn:_075808

increase shutter to 52

tn:_080041

luci1.20220119.0014

luci dark:luci1.20220119.0015

filter J

dark:0.016

tn:080730,_

luci.0017

pause/resume

cube5:080848,_080948

done 1:13am

Analysis.

bin4

  • J band
  • Tn:080730
  • SR: 7%
psf_20220119_J_bin4.png

TN:080848

SR:5%

psf_20220119_080848.png

Bin1

  • Tn:20220119_074254
  • SR:80%
psf_20220119_074254.png modalplot_20220119_074254.png

-- JuanCarlosGuerra - 18 Jan 2022
I Attachment Action Size Date Who Comment
BIN2_20220118.pngpng BIN2_20220118.png manage 70 K 19 Jan 2022 - 05:11 JuanCarlosGuerra  
BIN3_FAINT_20220118.pngpng BIN3_FAINT_20220118.png manage 60 K 19 Jan 2022 - 05:18 JuanCarlosGuerra  
BIN4_20220118_OCAM.pngpng BIN4_20220118_OCAM.png manage 85 K 19 Jan 2022 - 05:14 JuanCarlosGuerra  
bin1-seeing09_gopt_20220119.pngpng bin1-seeing09_gopt_20220119.png manage 116 K 19 Jan 2022 - 07:57 JuanCarlosGuerra  
bin1_20220118.pngpng bin1_20220118.png manage 67 K 19 Jan 2022 - 06:16 JuanCarlosGuerra  
bin1_seeing08_modal_20220119.pngpng bin1_seeing08_modal_20220119.png manage 219 K 19 Jan 2022 - 07:57 JuanCarlosGuerra  
bin1_shifted_20220118.pngpng bin1_shifted_20220118.png manage 78 K 19 Jan 2022 - 07:16 JuanCarlosGuerra  
bin2_badframe_20220118.pngpng bin2_badframe_20220118.png manage 120 K 19 Jan 2022 - 01:52 JuanCarlosGuerra  
bin3_20220118.pngpng bin3_20220118.png manage 108 K 19 Jan 2022 - 04:48 JuanCarlosGuerra  
bin3_faint-20220118.pngpng bin3_faint-20220118.png manage 95 K 19 Jan 2022 - 05:50 JuanCarlosGuerra  
bin3_faint_pass2_20220118.pngpng bin3_faint_pass2_20220118.png manage 64 K 19 Jan 2022 - 06:13 JuanCarlosGuerra  
bin3_pass2_pupil20220119_035330_20220118.pngpng bin3_pass2_pupil20220119_035330_20220118.png manage 108 K 19 Jan 2022 - 06:51 JuanCarlosGuerra  
bin3_shift_1_1.pngpng bin3_shift_1_1.png manage 73 K 19 Jan 2022 - 03:47 JuanCarlosGuerra  
bin4_20220118.pngpng bin4_20220118.png manage 63 K 19 Jan 2022 - 05:35 JuanCarlosGuerra  
modalplot_20220119_074254.pngpng modalplot_20220119_074254.png manage 31 K 20 Jan 2022 - 02:42 JuanCarlosGuerra  
psf_20220119-080848.pngpng psf_20220119-080848.png manage 49 K 20 Jan 2022 - 02:38 JuanCarlosGuerra  
psf_20220119_074254.pngpng psf_20220119_074254.png manage 46 K 20 Jan 2022 - 02:41 JuanCarlosGuerra  
psf_20220119_080848.pngpng psf_20220119_080848.png manage 45 K 19 Jan 2022 - 08:16 JuanCarlosGuerra  
psf_20220119_J_bin4.pngpng psf_20220119_J_bin4.png manage 44 K 20 Jan 2022 - 02:36 JuanCarlosGuerra  
Topic revision: r4 - 20 Jan 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback