20211130_SX_Day AZ Science + DEC. Bin 4 ESM tests + bin 2 ADI

00:50 OSCO
  • out of focus

01:12 StopAO to look at GCS guide

01:27 RetroCube in beam
  • Parked it

01:34 OSCO
  • Failed AdSec on Optimize Gain

01:52 OSCO
  • 015831
  • 020333

02:06 Preset to Bin 4 ESM

02:09 OCAM not live on Center Pupils

02:20
  • 021945
  • 022421
  • Poor image quality with TT,H01 1.5, 0.05 and 1.5, 0.2.
  • Much more TT and we get skip frames.
  • Much more H01 and then pupils on OCAM are definetly not flat
  • Quit, next target

02:30 Preset to Bin 2 star
  • OK
  • 023923
  • 024035
  • Looks good. Modal plot good, Gopt stable
  • 024339

05:35 Start AO Science. Preset to Bin 2 for ADI
  • 055256
  • 055256_modal.jpg:
    055256_modal.jpg
  • 061030
  • 070101

07:58 Loop closed on WFS but Pause
  • AdSec received Pause command, set 0 gain and had status PauseAO
AdSecArbitrator_139133|INF|      1691|2021-12-01 07:57:07.233013|            MAIN > Received cmd: PauseAo()
AdSecArbitrator_139133|INF|      1692|2021-12-01 07:57:07.233077|  COMMANDHANDLER > FSM (status: AORunning) has received command 2027 (Pause Ao)
AdSecArbitrator_139133|WAR|      1693|2021-12-01 07:57:07.233355|             IDL > Tip-tilt gain is set to zero. Offload disabled until next setGain command
AdSecArbitrator_139133|INF|      1694|2021-12-01 07:57:07.242397|  COMMANDHANDLER > Command Pause Ao (code 2027) successfully completed
20210112 07:57:26.5088 Alert: HighOrderOffload: HighOrderOffload vector ready
  • WFS did not receive a Pause command so was in state LoopClosed
  • guis.jpg:
    guis.jpg
  • AOS showed PauseAO running for many minutes till finally timeout
Wed Dec 1 08:07:07.248 2021 aos.Pause{FLAO}.failed - Pause{FLAO}[198] - [Exception] exception ::Ice::TimeoutException{}
Wed Dec 1 08:07:11.917 2021 aos.Resume{FLAO}.started - Resume{FLAO}[198] 
Wed Dec 1 08:07:11.932 2021 aos.Resume{FLAO}.failed - Resume{FLAO}[198] - Illegal command for state AOArbitrator.LoopClosed

08:15 Stop/start wfsarbitrator. All consistant now
  • Sent Pause from Command GUI. Pause completed but AdSec recieved StopAO from somewhere.
AdSecArbitrator_139133|INF|      1751|2021-12-01 08:16:13.236175|  COMMANDHANDLER > FSM (status: AORunning) has received command 2027 (Pause Ao)
AdSecArbitrator_139133|WAR|      1752|2021-12-01 08:16:13.236366|             IDL > Tip-tilt gain is set to zero. Offload disabled until next setGain command
AdSecArbitrator_139133|INF|      1753|2021-12-01 08:16:13.244971|  COMMANDHANDLER > Command Pause Ao (code 2027) successfully completed
AdSecArbitrator_139133|INF|      1754|2021-12-01 08:16:15.784579|            MAIN > Received cmd: StopAo(1)
AdSecArbitrator_139133|INF|      1755|2021-12-01 08:16:15.784674|  COMMANDHANDLER > FSM (status: AOPause) has received command 2015 (Stop Ao)
AdSecArbitrator_139133|INF|      1756|2021-12-01 08:16:15.784691|   SERIALIZATION > StopAoImpl(): restoreShape = 1
  • WFS state still LoopClosed
  • Click Open on WFS GUI
  • AdSec and WFS states now consistant

08:24 Reclose loop from FLAO GUI. OK
  • Optimize Gain
  • Optical Gain
  • NCPA On
  • Continue taking data
  • Lost 28 minutes
  • 082934
  • 085829

-- DougMiller - 01 Dec 2021

I Attachment Action Size Date Who Comment
055256_modal.jpgjpg 055256_modal.jpg manage 46 K 01 Dec 2021 - 06:07 DougMiller  
aos.jpgjpg aos.jpg manage 118 K 01 Dec 2021 - 09:19 DougMiller  
guis.jpgjpg guis.jpg manage 508 K 01 Dec 2021 - 09:19 DougMiller  
Topic revision: r3 - 01 Dec 2021, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback