• shutter 48
  • mag 17

u Nov 25 16:33:46.543 2021 aos.info - Updated variable AOARB.L.RR_ENABLED: 1
Thu Nov 25 16:34:59.255 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[34] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

pupils 20211124_171903

pupil has one pixel in x direction to the center.

load flat 20211123.sav

312Hz,3,600

optimize gain.

Failed.

bin4-pupil20211124_171903.png

loaded default pupils
  • 20211117_192657
  • this pupils shows to be in the camera lens range.
Thu Nov 25 17:02:17.366 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[39] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Nov 25 17:02:1

bin4_20211117_192657_20211125.png

optimize gain

gopt

bin4_20211117_192657_day20211125_2.png
  • gopt->0.07
  • pupils looks like a defocus not offloaded.
  • gopt->1.87
  • tn:20211125_171609
  • rotator angle->178.250
  • RotatorOffsetBin4 float 348.75 #DLM Adjusted 21211122 after changing homing speed
Thu Nov 25 17:19:12.308 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[41] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
  • RotatorOffsetBin4 float 350.25
  • optimize gain
  • bin4-20211117_192657_reo350p25.png
  • gopt->0.08
  • tn:20211125_172609
  • rerot was at 178.25
  • homing rerot.
  • optimize
  • bin4_secondpass_20211125_192657_good psf.png
  • tn:20211125_173408
  • psf good...
  • tn:173555
loaded disturbance.

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Nov 25 17:37:56.936 2021 aos.info - WFS source set to: FLAOWFS
Thu Nov 25 17:37:56.998 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits
  • rerot moving to 179.735
  • optimize gain
  • failed in the second pass
  • bin4_dist_20211117_192657.png

home rerot.

preset

rerot->179.753

close loop.
  • lngain
  • 20211125_175215.
  • round psf
  • optimize
  • 20211125_175433
  • good psf
bin4_optimize_dist_20211117__.png
  • bin4-optimize_gopt_20211117__.png
  • tn:20211125_175733.
  • good PSF
change rotator offset fro bin4

RotatorOffsetBin4 float 348.75 #DLM Adjusted 21211122 after changing homing speed


Thu Nov 25 18:00:50.481 2021 aos.AcquireRef{FLAO}.complete - AcquireRef{FLAO}[46] - dx:0.29969 dy:1.98221 slNull: f1:0.0 f2:1.0 freq:312 mag:0 nBins:4 nModes:54 r0:nan snMode:0 strehl:0 ttMod:0
Thu Nov 25 18:00:52.158 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[47] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Nov 25 18:00:52.174 2021 aos.info - WFS source set to: FLAOWFS
Thu Nov 25 18:00:52.239 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits
  • rerot 178.253
  • close loop
  • lngain
  • 20211125_180348
  • round psf good.
  • optimize gain
  • failed..ho1
  • failed second time.
  • failed_optimize_bin4_dist.png

  • move rerot to 179.753
  • tracking off
  • optimize gain
  • failed second pass
  • loop close with LN
  • 20211125_181043
  • round psf

loaded default rerot offset for Bin4
  • home rerot

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Nov 25 18:14:05.268 2021 aos.info - WFS source set to: FLAOWFS
Thu Nov 25 18:14:09.971 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits
  • rerot 179.725
  • close loop
  • lngain
  • 20211125_181709
  • round psf
  • psf_lngain_bin4.png
  • optimize gain
  • first try failed.
  • second try failed
open loop

reload flat

close loop and optimize gain

tn20211125_182250

good psf

psf_optimizegain_bin4.png

-- JuanCarlosGuerra - 25 Nov 2021