bin 4 preset. mag 17

Tue Nov 23 16:23:32.221 2021 aos.PresetAO{FLAO}.complete - PresetAO{FLAO}[110] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:312 mag:0 nBins:4 nModes:54 r0:nan snMode:0 strehl:0 ttMod:0

generation of pupil shift from 20200916_173857

x=2,y=1

loaded pupil 20211123_162056

optimize gain failed.

remove distrubance.

Tue Nov 23 17:09:49.886 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[112] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

e Nov 23 18:01:07.970 2021 aos.info - Stages offset applied - dx: 0; dy: 0
Tue Nov 23 18:01:07.987 2021 aos.AcquireRef{FLAO}.complete - AcquireRef{FLAO}[115] - dx:0 dy:0 slNull: f1:0.0 f2:1.0 freq:312 mag:0 nBins:4 nModes:54 r0:nan snMode:0 strehl:0 ttMod:0
Tue Nov 23 18:02:21.520 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[116] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Nov 23 18:02:21.537 2021 aos.info - WFS source set to: FLAOWFS
Tue Nov 23 18:02:21.602 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits

disturbance doen;t looks good.

without disturbance.

same shape after the close loop...

AO preset.

reshape with 20211123.sav

Tue Nov 23 18:27:43.752 2021 aos.PresetAO{FLAO}.complete - PresetAO{FLAO}[121] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:312 mag:0 nBins:4 nModes:54 r0:nan snMode:0 strehl:0 ttMod:0
Tue Nov 23 18:28:11.861 2021 aos.AcquireRef{FLAO}.started - AcquireRef{FLAO}[122] Mode: Move stages, Automatic acquire
Tue Nov 23 18:28:23.616 2021 aos.info - FLAO: WFS: center star

center pupil good shape...

After the pupil; centering

pupil_centering-bin4-20211123.png

presetAO mag 17

the camera lens seems not moving in the x direction.

pwer off/on

the y axis seems not responding.

11:44am

After seeing that the load shape gave a different flat from the pupil centering to the close loop and the camera lens.

decided to perform a clean startup for both systems.

warmup the ocam

stop wfs and adsc

setflat->638

Tue Nov 23 19:06:05.113 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[123] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Tue Nov 23 19:20:12.763 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[126] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Cancel preset.

Tue Nov 23 19:30:57.785 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[129] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Nov 23 19:30:57.802 2021 aos.info - WFS source set to: FLAOWFS
Tue Nov 23 19:30:58.869 2021

loaded flat->20211123.sav

bin4_pupilcentering_22.png

close loop

b4_lngain_20211123.png

Changing the gain manually, doen;t improve the pupils illuminaiton.

The Argos cal unit can be open to 80.

open loop

Tue Nov 23 19:53:17.574 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[132] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Nov 23 19:53:17.593 2021

center pupil. Argos to 80

after-centerpupil_bin4_20211123.png

close loop

lngain

shows a static pattern.

TN20211123_195951

a pattern is running int he secondary...

loaded distrubance

exception:Traceback (most recent call last): File "aoarbitrator.py", line 990, in RequestAOStatus fstat=self._fsm.getState().getName().split('.') File "/home/aoeng/soul/pause_resume_test_20211011/aoroot/lib/python/statemap.py", line 104, in getState raise StateUndefinedExceptionStateUndefinedException
Tue Nov 23 20:03:49.432 2021 aos.warning - FLAO: error on status request from AO Arb. Excp: src/Ice/OutgoingAsync.cpp:1049: ::Ice::UnknownException:unknown exception:Traceback (most recent call last): File "aoarbitrator.py", line 990, in RequestAOStatus fstat=self._fsm.getState().getName().split('.') File "/home/aoeng/soul/pause_resume_test_20211011/aoroot/lib/python/statemap.py", line 104, in getState raise StateUndefinedExceptionStateUndefinedException
Tue Nov 23 20:03:49.610 2021 aos.Stop{FLAO}.complete - Stop{FLAO}[135]
Tue Nov 23 20:06:53.012 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[136] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Nov 23 20:06:53.031 2021 aos.info - WFS source set to: FLAOWFS
Tue Nov 23 20:06:53.096 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq200.0000_sd3892.fits

center upil ok

good pupil looking.

stop

1:30-2:20 PM

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Nov 23 21:24:35.857 2

-- JuanCarlosGuerra - 23 Nov 2021
Topic revision: r2 - 23 Nov 2021, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.