Staff

Summay

Test Bin4 in close loop.

Check for camera lens positions vs rotation.

Detais.

un Dec 5 13:28:49.871 2021 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[630] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Dec 5 13:28:49.886 2021 aos.info - WFS source set to: FLAOWFS
Sun Dec 5 13:28:49.956 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits

shutter 50

center pupil failed.

Camera lens temperature too low.

bFunc doCenterPupils (, 'FLAOWFS', 'LUCIFER')

WfsArbitrator _159178|ERR| 262|2021-12-05 13:35:50.345605| MAIN > RETRY: Camera lens temperature too low. T= 5.17, minimum allowed is 7.00 (0) NO_ERROR

wait to see if temperature raises..

wfsarb has the definition for the camera lens checking.
  • # Cameralens temperature checking
  • cameralensTempCheck int 1
  • cameralensTempMin float 7.0
  • cameralensTempNumber int 8
close loop

bin4, 312Hz,EMgain=600

6:44 am

running center pupil

close loop

bin4_pupil20211203_143545_lngain.png
  • LNgain
  • J
  • 5 frames
  • 20211205_134806
  • H
  • 10frames
  • 20211205_135121
adsec_lngain_bin4_20211203_143545.png

optimize
  • 1.18,1.04,0.10
  • no skip frames
  • 135359
  • J
  • 5frames
  • _135603
  • shutter 45
  • mag 16.7
  • 135809

bin4-opti-20211203_143445.png

optimize gain
  • 1.03,1.36.0.10
  • slope rms->0.76
  • 140106
  • luci1.20211205_5006
  • gopt
  • 0.18,0.23,0.02
  • _140321
bin4_20211203_143545_optimize2.png

bin4-goptoptimize2_20211203_143545.png

pause
  • light off
  • luci dark.
  • .5008
psf_bin4_20211203_143545.png

pause/resume
  • 140626
  • .5009
StopAO

entGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Dec 5 14:08:09.279 2021 aos.info - WFS source set to: FLAOWFS
Sun Dec 5 14:08:09.344 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits
  • shutter 43
  • mag 17.3
  • close loop
  • optimize gain
  • 5.49,0.09,0.10
  • too faint
  • 141528
stop close loop

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Dec 5 14:17:38.527 2021 aos.info - WFS source set to: FLAOWFS
Sun Dec 5 14:17:38.589 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits

shutter 46

mag 16.3

bin4_20211203_143545_run2.png

bin4-run2_lngain.png
  • 142200
execute optimize gain during the data acq....

optimize

1.33,1.07,0.5

bin4_20211203_143545_optimize2.png

save luci+ccd47
  • 142425
  • .5012
gopt
  • 0..2.3,0.19,0.02
  • .5013
  • 142656
bin4-gopt-run2.png

rotation check.

CL x=-39,y=21 @340

>>> makePupils.movePupils('20200916_173857_LBTI',2,2,240,5)

makePupils_fromMasks(): moving from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211205_144238/pupdata.txt
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211205_144238/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211205_144238
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211205_144238"
'20211205_144238
  • loaded the pupil
  • 20211205_144238
  • CLx=12.3, y=63 @360
  • good
bin4_20211205.png

  • change AO table for ACE.
  • lrwxrwxrwx. 1 AOeng AOeng 33 Dec 5 15:05 table_LUCIFER_ACE-AO.txt -> table_LUCIFER_ACE-AO.txt.20211205

Sun Dec 5 15:07:28.732 2021 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[640] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Dec 5 15:07:28.755 2021 aos.info - WFS source set to: FLAOWFS
Sun Dec 5 15:07:29.485 2021 aos.info - FLAO: WFS: loading setup for LUC

center pupil

close loop
  • lngain
  • 151333... during the optimize gain
load disturbance.

Sun Dec 5 15:15:17.350 2021 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[641] - dx:0.248515 dy:-0.627498 slNull: f1:0.0 f2:1.0 freq:312 mag:0 nBins:4 nModes:54 r0:nan snMode:0 strehl:0 ttMod:0
Sun Dec 5 15:15:35.052 2021 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[642] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Dec 5 15:15:35.066 2021 aos.info - WFS source set to: FLAOWFS
Sun Dec 5 15:15:35.128 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits

bin4_pupilpos_20211205_144238.png

close loop
  • lngain
  • _151930
  • luci.5015
bin4_20211205_144238.png

optimize
  • no skip fframes
  • 1.16,0.95,0.10
  • 152138
  • .5016
bin4_20211205_144238_opti.png

gopt
  • 0.23,0.19,0.02
  • _152341,42
  • .5017,18
bin4_20211205_144238_gopt.png
  • frame->10
  • 152623
  • luci .5019
  • luci dark
  • 5 frames
  • .5020
  • 10 frames
  • .5021
resume

gopt_bin4_pupil20211205_144238.png
  • 153054
  • .5022
bin4_20211205-144238_gopt2.png

Handover.

8:30am

-- JuanCarlosGuerra - 05 Dec 2021
Topic revision: r2 - 06 Dec 2021, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.