Staff.

Summary.

Fabio has a new version of the makePupil python to try.

Get a new pupil shift for Bin4, x=1, y=2. Close loop test and acquire TN for posteriori analysis. It is noly one hour available.

The new pupil built shows to have a much better performances and it workied in ca close loop with a disturbance. The PSF shows to be corrected reporting a SR of about 17% in J band.

Detail.

Early startup.

Dave said that there are not calibrations for MODS.

Telescope running the closure procedure and Elliot will fill the instrument before I start.

Fabio updated the makepupils version to test with a pupil shift and close loop performances.

new pupil generation..

>>> makePupils.movePupils('20200916_173857',1,2,240,5)
makePupils_fromMasks(): moving from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211203_143545/pupdata.txt
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211203_143545/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211203_143545
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211203_143545"
'20211203_143545'
>>>

>>> makePupils.movePupils('20200916_173857_LBTI',1,2,240,5)
makePupils_fromMasks(): moving from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211203_193238/pupdata.txt
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211203_193238/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211203_193238
/bin/mv -f "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/AOeng/pause_resume_test_20211011/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20211203_193238"
'20211203_193238'
>>>

the diff of the two files are identical, the only difference is the header of the pup*.fits that it save the origin pupil name.

[AOeng@soul-sxwfs mode5]$ diff 20211203_143545 20211203_193238
Binary files 20211203_143545/pup1.fits and 20211203_193238/pup1.fits differ
Binary files 20211203_143545/pup2.fits and 20211203_193238/pup2.fits differ
Binary files 20211203_143545/pup3.fits and 20211203_193238/pup3.fits differ
Binary files 20211203_143545/pup4.fits and 20211203_193238/pup4.fits differ
[AOeng@soul-sxwfs mode5]$

setfalt->638

7:55am

Argos cal unit deployed and ready for testing...

Dec 3 14:56:27.294 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[541] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Dec 3 14:56:27.308 2021 aos.info - WFS source set to: FLAOWFS
Fri Dec 3 14:56:27.355 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.0000_sd3892.fits
Fri Dec 3 14:56:28.356 2021 aos.info - FLAO: WFS: loading setup for LUCIFER

shutter 50

luci setup: J band, cube of 5 images.

close loop
  • lngain
  • 20211203_150451
  • optimize gain
  • no skip frame
  • TN: 20211203_150820
  • gopt:
  • 0.24,0.18,0.02
  • _151533
  • pause
  • light off
  • Luci dark
  • resume
  • The first image of the cube shows to be elongated...
  • tn:_151950
  • optimizegain:
  • 1.23,1.32,0.10
  • some oscillation ...
  • _152200
  • psf
  • gopt
  • 0.26,0.27,0.02
  • tn:_152510
  • SR->0.16
centerPupil_bin4_20211203.png

psf_bin4_20211203.png

gopt_bin4-20211203.png

No disturbance

Juan Pablo goes to the upper tree house


Fri Dec 3 15:31:25.858 2021 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[547] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Dec 3 15:31:25.879 2021 aos.info - WFS source set to: FLAO

preset cancel.

no star in the cccd47

hexapod reposition.

load flat

shutter 48

centerPupil_bin4_20211203.png

close loop
  • lngain:
  • 153932
  • optimizegain
  • TT oscillation... there is some work in the upper tree house...pupil jumping around.
  • skip frames
  • try again.
  • it show a low tt gain.
  • 0.05,0.44,0.10
  • _154505
  • rise tt manually
  • 0.83,0.44,0.10
  • tn:_154646
  • 0.85,0.54,0.10
  • 154823
  • gopt
  • 0.28,01.8,0.05
  • _155200
  • optimize gain.
  • no skip frames.
  • 0.12,0.44,0.10
  • _155444
  • gopt
  • 0.05,0.18,0.04

stop->8:58am

Data analysis.

diff of directories.

diff 20211201_181140 20211203_143545

attach the file.

diff_20211203_143545and20211201_181140.txt

-- JuanCarlosGuerra - 03 Dec 2021
Topic revision: r4 - 07 Dec 2021, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback