Staff:

LBTO:Juan Carlos, Alessandro

Summary:

Details:

Power ON

  • Startup timeout.
WfsArbitrator _178151|INF| 50|2021-07-01 15:13:16.036923| MAIN > Turning on PROG_BCU_2K

WfsArbitrator _178151|INF| 51|2021-07-01 15:13:46.037754| MAIN > Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR - GENERIC_SYS_ERROR
WfsArbitrator_178151|ERR| 52|2021-07-01 15:13:46.037836| MAIN > Exception: Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR
WfsArbitrator_178151|ERR| 53|2021-07-01 15:13:46.037888| MAIN > Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR (-1000) GENERIC_SYS_ERROR

Second power on.->OK.

Check Ocam-> Not live.
  • Power cycle BCU2K
  • Change binning
  • Ocam live
WFS dark frames acquired.
  • 20210701_153432
Board setup torr9.
  • timeout error bayside stage
The bayside stage in Y direction shows to be loaded. it moves negative, current goes to 1A and it is stay there.. Try to move positive direction and it doen;t move ???.

Position bayside stage -50.

Rotator OFF, position 341.

brakes on/of

move positive.

take WFS dark


WfsArbitrator_178151|INF| 169|2021-07-01 15:59:38.258423| MAIN > selectHODark(): selected dark file 20210701_155936.fits

Internal check of camera lens prcedure:
  • Pennina with the cuber directly on wfs.
  • steer the cube in order to minimize the vignetting.
  • disable pupil rotation tracking from WFSarbitrator.
  • center pupils with the stages.
  • apply modulation 20l/D
  • verify pupil check process is measuring the pupils.
  • ... for rtoation test:
  • Rotate the Luci rotator
  • From DMS check that the pupil position and error are updating.

High bay lights OFF.

take a dark

Board setup: Internal

Align the pupil using the bayside stage.

Movement of the cube rotator by -0.5 and lost the source.

Restore the board setup:

Pupils visible.

Change CCD setup:

bin1,200,6lD,1

align with bayside stage.

taking track number _165931
  • _170236
10L/D
  • _170536
20l/D
  • _170722
measuremenets:

first run:

  • 4l/D:173307
  • 6l/D:173359
  • 10l/D:173430
  • 15l/D:173453
  • 20l/D173528
  • 25l/D173528
  • 30l/D:173639

second run

  • 30L/D: _173908
  • 25l/D:174018
  • 20/D:174051
  • 15l/D:174121
  • 10l/D:174144
  • 8/D:174212
  • 6/D 174237
  • 5/D 174306
  • 4/d 174333
  • 3l/d 174359.

SAVE BOARD SETUP: Internal_pupilcheck

  • park cube stage and rotator.

STOP 10:30

-- JuanCarlosGuerra - 01 Jul 2021
Topic revision: r4 - 06 Oct 2021, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback