POWER ON

  • OK
  • SAVE OCAM FRAMES.
  • ocam not live.
  • Power cycle BCU2K
  • Cha ge binning.
  • Ocam live.
  • save frames.
  • The optical loop diagnostic not saving frames.
  • w_stop_all
  • w_start_all
WfsArbitrator _55400|INF| 51|2021-05-07 19:42:47.150548| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = '', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_194246/wfs.fits')

WfsArbitrator _55400|INF| 58|2021-05-07 19:47:23.649959| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 10, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

loop close, but observed that it was loaded a disturbance of 200Hz.

ri May 7 20:09:26.515 2021 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[37] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri May 7 20:09:26.532 2021 aos.info - WFS source set to: FLAOWFS
Fri May 7 20:09:26.592 2021 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq200.0000_sd3892.fits
Fri May 7 20:09:27.288 2021 aos.info - FLAO: WFS: loading setup for LUCIFER

Disable the 200Hz disturbance.

close loop.

all modes corrected.

WfsArbitrator _55400|INF| 352|2021-05-07 20:38:16.827707| OPTLOOPDIAG > Executing save...

WfsArbitrator _55400|INF| 353|2021-05-07 20:38:20.002082| WFS > Executing saveStatus...

WfsArbitrator _55400|INF| 354|2021-05-07 20:38:20.002169| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_203816/wfs.fits')

Gopt ->ok

WfsArbitrator _55400|INF| 367|2021-05-07 20:41:18.002384| WFS > Executing saveStatus...

WfsArbitrator _55400|INF| 368|2021-05-07 20:41:18.002466| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_204116/wfs.fits')

WfsArbitrator _55400|INF| 369|2021-05-07 20

check Bin2

fsArbitrator_55400|INF| 388|2021-05-07 20:42:24.750035| WFS > Executing presetAO...

WfsArbitrator _55400|INF| 389|2021-05-07 20:42:24.750142| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 14, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _55400|INF| 461|2021-05-07 20:48:05.001095| WFS > Executing saveStatus...

WfsArbitrator _55400|INF| 462|2021-05-07 20:48:05.001158| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_204803/wfs.fits')

optimiza gain->ok

WfsArbitrator _55400|INF| 478|2021-05-07 20:50:15.001882| WFS > Executing saveStatus...

WfsArbitrator _55400|INF| 479|2021-05-07 20:50:15.001932| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_205013/wfs.fits')

WfsArbitrator _55400|INF| 480|2021-05-07 20

BIN1 PUP ROT.

bin1_may7.png

BIN1_MAY7_ERR.png

BIN3 PUP ROTATION

bin3_may7.png

bin3_may7_err.png

Close loop bin1

  • Bin1, 1.7KHz.
  • dist s1.6
  • optimize gain->OK
  • slope rms 0.4
  • gopt ->failed.
python_95661 |INF| 64|2021-05-07 22:06:22.624672| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 6.71e-09/1.3e-08 gopt: 1.000

python_95661 |INF| 65|2021-05-07 22:06:27.238044| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.29e-08/1.29e-08 gopt: 0.516

python_95661 |INF| 66|2021-05-07 22:06:32.118461| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.27e-08/1.28e-08 gopt: 0.516

python_95661 |INF| 67|2021-05-07 22:06:37.598963| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.3e-08/1.29e-08 gopt: 0.516

python_95661 |INF| 68|2021-05-07 22:06:42.343045| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.29e-08/1.29e-08 gopt: 0.515

python_95661 |INF| 69|2021-05-07 22:06:47.458810| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.29e-08/1.29e-08 gopt: 0.515
  • optimize gain->ok
  • gopt ->failed.
  • stop gopt process.
  • optimize gain->ok
  • gopt ->ok
5-07 22:04:37.537343| WFS > Executing startGopt...

WfsArbitrator _55400|INF| 1986|2021-05-07 22:04:37.537446| WFS > Python command: WfsArbScripts.startGopt(self, sensor = 'FLAOWFS', instr = 'LUCIFER')

WfsArbitrator _55400|WAR| 1987|2021-05-07 22:04:37.538273| WFS > Command returns retryable error : RETRY: Optical gain is not one, cannot start tracking (-5002) VALUE_OUT_OF_RANGE_ERROR

WfsArbitrator _55400|INF| 1988|2021-05-07 22:04:49.904570| COMMANDHANDLER > FSM (status: LoopClosed) has received command 2037 (OptimizeGain)

WfsArbitrator _55400|INF| 1989|2021-05-07 22:04:49.904641| WFS > Executing optimizeGain...

WfsArbitrator _55400|INF| 1990|2021-05-07 22:04:49.904681| WFS > Python command: WfsArbScripts.optimizeGain(self, sensor = 'FLAOWFS', instr = 'LUCIFER')

WfsArbitrator _55400|INF| 1991|2021-05-07 22:05:53.558019| WFS > Command returns success .

WfsArbitrator _55400|INF| 1992|2021-05-07 22:05:53.558079| COMMANDHANDLER > Command OptimizeGain (code 2037) successfully completed

WfsArbitrator _55400|INF| 1993|2021-05-07 22:06:02.935951| WFS > Executing startGopt...

WfsArbitrator _55400|INF| 1994|2021-05-07 22:06:02.936021| WFS > Python command: WfsArbScripts.startGopt(self, sensor = 'FLAOWFS', instr = 'LUCIFER')

WfsArbitrator _55400|INF| 1995|2021-05-07 22:06:12.523104| MAIN > Camera lens tracking: moving by x= -1.0 y= -0.8 (um)

WfsArbitrator _55400|INF| 1996|2021-05-07 22:06:13.810095| MAIN > Camera lens tracking: moving by x= 1.4 y= 0.4 (um)

WfsArbitrator _55400|INF| 1997|2021-05-07 22:06:37.609934| WFS > Command returns success .

WfsArbitrator _55400|INF| 1998|2021-05-07 22:06:37.610792| WFS > Executing startGopt...

WfsArbitrator _55400|INF| 1999|2021-05-07 22:06:37.610843| WFS > Python command: WfsArbScripts.startGopt(self, sensor = 'FLAOWFS', instr = 'LUCIFER')

WfsArbitrator _55400|WAR| 2000|2021-05-07 22:06:37.611366| WFS > Command returns retryable error : RETRY: Optical gain is not one, cannot start tracking (-5002) VALUE_OUT_OF_RANGE_ERROR

WfsArbitrator _55400|INF| 2001|2021-05-07 22:08:06.548427| COMMANDHANDLER > FSM (status: LoopClosed) has received command 2037 (OptimizeGain)

WfsArbitrator _55400|INF| 2002|2021-05-07 22:08:06.548524| WFS > Executing optimizeGain...

WfsArbitrator _55400|INF| 2003|2021-05-07 22:08:06.548605| WFS > Python command: WfsArbScripts.optimizeGain(self, sensor = 'FLAOWFS', instr = 'LUCIFER')

WfsArbitrator _55400|INF| 2004|2021-05-07 22:09:09.738618| WFS > Command returns success .

WfsArbitrator _55400|INF| 2005|2021-05-07 22:09:09.738658| COMMANDHANDLER > Command OptimizeGain (code 2037) successfully completed

WfsArbitrator_55400|INF| 2006|2021-05-07 22:09:16.527035| WFS > Executing startGopt...

WfsArbitrator_55400|INF| 2007|2021-05-07 22:09:16.527149| WFS > Python command: WfsArbScripts.startGopt(self, sensor = 'FLAOWFS', instr = 'LUCIFER')

WfsArbitrator_55400|INF| 2008|2021-05-07 22:09:49.044375| WFS > Command returns success .

WfsArbitrator _55400|INF| 2009|2021-05-07 22:10:01.034157| MAIN > Camera lens tracking: moving by x= 1.0 y= 0.3 (um)

WfsArbitrator _55400|INF| 2013|2021-05-07 22:11:18.002441| WFS > Executing saveStatus...

WfsArbitrator _55400|INF| 2014|2021-05-07 22:11:18.002518| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_221115/wfs.fits')

WfsArbitrator _55400|INF| 2015|2021-05-07 22:11:18.039

WfsArbitrator _55400|INF| 2019|2021-05-07 22:11:41.001362| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_221139/wfs.fits')

WfsArbitrator _55400|INF| 2020|2021-05-07 22:11:41.036619| WFS > Command returns success .

  • close loop good.
  • Change modes to 500.
  • Doug made changes in IDL and file compile in IDL
  • Close loop check.
  • optimize ->ok
  • gopt->ok
  • AO SR:84%
WfsArbitrator _55400|INF| 2110|2021-05-07 22:22:19.126379| OPTLOOPDIAG > Executing save...

WfsArbitrator _55400|INF| 2111|2021-05-07 22:22:21.003097| WFS > Executing saveStatus...

WfsArbitrator _55400|INF| 2112|2021-05-07 22:22:21.003149| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_222219/wfs.fits')

WfsArbitrator _55400|INF| 2113|2021-05-07 22:22:21.035218| WFS > Command returns success .

python_178458 |INF| 27|2021-05-07 22:22:20.638416| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.26e-08/1.28e-08 gopt: 0.491

python_178458 |INF| 28|2021-05-07 22:22:26.013305| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.25e-08/1.28e-08 gopt: 0.489

python_178458 |INF| 29|2021-05-07 22:22:32.546005| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.28e-08/1.27e-08 gopt: 0.490

WfsArbitrator _55400|INF| 2127|2021-05-07 22:25:19.001565| WFS > Executing saveStatus...

WfsArbitrator _55400|INF| 2128|2021-05-07 22:25:19.001643| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_222517/wfs.fits')

rot angle to 341.

WfsArbitrator _55400|INF| 2161|2021-05-07 22:29:13.764004| WFS > Executing presetAO...

WfsArbitrator _55400|INF| 2162|2021-05-07 22:29:13.764109| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 10, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

optimize gain->ok

gopt->ok

bin1_s1.6_may7.png

WfsArbitrator _55400|INF| 2251|2021-05-07 22:37:08.003573| WFS > Executing saveStatus...

WfsArbitrator _55400|INF| 2252|2021-05-07 22:37:08.003660| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_223706/wfs.fits')

python_42880 |INF| 41|2021-05-07 22:37:38.730090| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.32e-08/1.32e-08 gopt: 0.513

python_42880 |INF| 42|2021-05-07 22:37:43.374620| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.31e-08/1.32e-08 gopt: 0.512

python_42880 |INF| 43|2021-05-07 22:37:47.977963| MAIN > Tracknum: 20210507_250000 demodDelta/demodCmd: 1.33e-08/1.32e-08 gopt: 0.513

WfsArbitrator _55400|INF| 2258|2021-05-07 22:37:50.091429| OPTLOOPDIAG > Executing save...

WfsArbitrator _55400|INF| 2259|2021-05-07 22:37:52.002505| WFS > Executing saveStatus...

WfsArbitrator _55400|INF| 2260|2021-05-07 22:37:52.002593| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210507/Data_20210507_223750/wfs.fits')

WfsArbitrator _55400|INF| 2261|2021-05-07

WfsArbitrator _55400|INF| 2271|2021-05-07 22:38:32.980193| COMMANDHANDLER > Command StopLoopAdsec (code 2033) successfully completed

WfsArbitrator _55400|INF| 2272|2021-05-07 22:38:45.457668| MAIN > Received cmd: setSafe()

WfsArbitrator _55400|INF| 2273|2021-05-07 22:38:45.457750| COMMANDHANDLER > FSM (status: AOSet) has received command 2043 (setSafe)

WfsArbitrator _55400|INF| 2274|2021-05-07 22:38:45.457786| WFS > Executing setSafe...

-- JuanCarlosGuerra - 07 May 2021