Summary.

Details.

Power on WFS.

  • ocam bias with two bad qudrants,
  • Going through the troubleshooting with Josh. He followed and executed the actions.
  • Bias good.
  • Leave ocam warm.
  • High wind.
2021-04-22 23:18:09.109771| COMMANDHANDLER > Command Operate (code 2004) successfully completed

2:03 Preparing to open. Telescope 30 degrees.
  • OCAM COLD.
  • BIAS FRAME
  • 2021-04-23 02:15:16.759317| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = '', outputFile = '/local/aomeas/adsec_data/20210423/Data_20210423_021515/wfs.fits').
2:24 Clouds passing collimation taking time.

OSCO

WfsArbitrator _126484|INF| 65|2021-04-23 02:31:56.759991| COMMANDHANDLER > FSM (status: Operating) has received command 2041 (PresetAO)

WfsArbitrator _126484|INF| 66|2021-04-23 02:31:56.760135| OPTLOOPDIAG > Executing enableAntiDrift(true)...

WfsArbitrator _126484|INF| 67|2021-04-23 02:31:56.760339| WFS > Python command: WfsArbScripts.updateNcpa(self, sensor = 'FLAOWFS', instr = 'LUCIFER', rotAngle = 0, zero = 1)

WfsArbitrator _126484|INF| 68|2021-04-23 02:31:56.762276| WFS > Executing presetAO...

WfsArbitrator _126484|INF| 69|2021-04-23 02:31:56.762394| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = 5.93935, starypos = 1.04201, telElevation = 0, derotAngle = 0, starMag = 7.53, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)
  • Stop the preset. Cancel.
  • set auto mode
WfsArbitrator _126484|INF| 83|2021-04-23 02:34:26.866436| WFS > Python command: WfsArbScripts.updateNcpa(self, sensor = 'FLAOWFS', instr = 'LUCIFER', rotAngle = 0, zero = 1)

WfsArbitrator _126484|INF| 84|2021-04-23 02:34:26.867781| WFS > Executing presetAO...

WfsArbitrator _126484|INF| 85|2021-04-23 02:34:26.867883| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = 2.88777, starypos = 2.78724, telElevation = 0, derotAngle = 0, starMag = 7.48, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)
  • sky bad.
  • star in the CCD47 comes and goes..
  • allsky_2021-04-22..png
  • Quick.
  • 06:30

all_sky_635.png

7:48 close by wind.

9:40 open. seeing 1.3"

10:05 seeing 1.3"

10:29 Switch to AO.

WfsArbitrator _126484|INF| 438|2021-04-23 10:38:53.525818| WFS > Python command: WfsArbScripts.updateNcpa(self, sensor = 'FLAOWFS', instr = 'LUCIFER', rotAngle = 0, zero = 1)

WfsArbitrator _126484|INF| 439|2021-04-23 10:38:53.527094| WFS > Executing presetAO...

WfsArbitrator _126484|INF| 440|2021-04-23 10:38:53.527201| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = 50.0107, starypos = -23.4796, telElevation = 0, derotAngle = 0, starMag = 14, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)
  • EL 28.
  • AOPreset sent. Interrupt command at the pupil centering. Cancel preset.
  • Too late for this target. Change target.
  • seeing 1.3"
ngc10266

WfsArbitrator _126484|INF| 482|2021-04-23 10:46:13.621131| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = 21.6405, starypos = -21.4039, telElevation = 0, derotAngle = 0, starMag = 16.57, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

**
  • PUPIL CENTRING FAILED.-> FAILURE ADSEC->PANIC. TO BE INVESTIGATED..
  • CALL guido (no answer),DOUG.
  • RESTART ADSEC (adsc_stop/start) BETTER SOLUTION.
  • RESTART WFS ARBITRATOR.
  • PRESETAO.
  • TOO SLOW TO OPTMIZE GAIN.. ALMOST A FLAT.
  • laggish communication, done optimize . no gopt.
  • Done and luci still waiting. IIF saids AO running.
  • Dave bypass the waiting to start the script with the skip of the first offset.
Seeing: 1.5"

**

variable seeing 1.2"-1.9"

WfsArbitrator _43946|INF| 42|2021-04-23 11:15:02.356274| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = 39.2126, starypos = -14.4842, telElevation = 0, derotAngle = 0, starMag = 12.99, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _43946|INF| 1289|2021-04-23 11:59:06.001469| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210423/Data_20210423_115903/wfs.fits')

WfsArbitrator _43946|INF| 1290|2021-04-23 11:59:06.064879| WFS > Command returns success .

WfsArbitrator _43946|INF| 1291|2021-04-23 11:59:06.066095| WFS > Executing savePsf...

WfsArbitrator _43946|INF| 1292|2021-04-23 11:59:06.066234| WFS > Python command: WfsArbScripts.savePsf(self, sensor = 'FLAOWFS', instr = 'LUCIFER', filename = '/local/aomeas/adsec_data/20210423/Data_20210423_115903/psf.fits', num = 5)

WfsArbitrator _43946|INF| 1293

WfsArbitrator _43946|INF| 1452|2021-04-23 12:09:05.001220| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20210423/Data_20210423_120903/wfs.fits')

WfsArbitrator _43946|INF| 1453|2021-04-23 12:09:05.036379| WFS > Command returns success .

WfsArbitrator _43946|INF| 1454|2021-04-23 12:09:05.037238| WFS > Executing savePsf...

WfsArbitrator _43946|INF| 1455|2021-04-23 12:09:05.037323| WFS > Python command: WfsArbScripts.savePsf(self, sensor = 'FLAOWFS', instr = 'LUCIFER', filename = '/local/aomeas/adsec_data/20210423/Data_20210423_120903/psf.fits', num = 5)

12:01 STOP

WfsArbitrator _43946|INF| 1462|2021-04-23 12:10:24.852352| MAIN > Received cmd: setSafe()

WfsArbitrator _43946|INF| 1463|2021-04-23 12:10:24.852455| COMMANDHANDLER > FSM (status: AOSet) has received command 2043 (setSafe)

-- JuanCarlosGuerra - 22 Apr 2021
Topic revision: r6 - 23 Apr 2021, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback