summary.

Detail.

[AOeng@soul-dxwfs SOUL]$ w_check

msgdrtdb NOT running

mirrorctrl NOT running

pinger running but UNKOWN connection state to Msgd

powerboard NOT running

slopecompctrl NOT running

techviewctrl NOT running

ocam2 NOT running

ccd47 NOT running

ttctrl NOT running

adc1 NOT running

adc2 NOT running

rerotator NOT running

filterwheel1 NOT running

filterwheel2 NOT running

mercury NOT running

cubestage NOT running

baysidex NOT running

baysidey NOT running

baysidez NOT running

cameralensctrl NOT running

picctrl NOT running

optloopdiag NOT running

pupilcheckocam2 NOT running

masterdiagnostic NOT running

housekeeperWFS NOT running

dbfiller NOT running

wfsarb NOT running

gopt NOT running

Error: w_check script UNABLE to connect to RTDB!

The exception wasthStart error(-2010): Connection closed at the other end
  • w_stop
  • w_start
[AOeng@soul-dxwfs SOUL]$ w_start

Side: R

Subsystem: WFS

startProcessByName(): starting process /home/AOeng/aoroot/bin/msgdrtdb

clean_ts8 script is disabled

-- Stage mirrorctrl pinger powerboard slopecompctrl techviewctrl ocam2 ccd47 ttctrl adc1 adc2 rerotator filterwheel1 filterwheel2 mercury cubestage baysidex baysidey baysidez cameralensctrl picctrl optloopdiag pupilcheckocam2

startProcessByName(): starting process /home/AOeng/aoroot/bin/MirrorCtrl -i mirrorctrl

startProcessByName(): starting process /home/AOeng/aoroot/bin/Pinger -i pinger

startProcessByName(): starting process /home/AOeng/aoroot/bin/RelayCtrl -i powerboard

startProcessByName(): starting process /home/AOeng/aoroot/bin/SlopeCompCtrl2K -i slopecompctrl

startProcessByName(): starting process /home/AOeng/aoroot/bin/FrameGrabberCtrl -i techviewctrl

startProcessByName(): starting process /home/AOeng/aoroot/bin/OCAM2Ctrl -i ocam2

startProcessByName(): starting process /home/AOeng/aoroot/bin/JoeCtrl -i ccd47

startProcessByName(): starting process /home/AOeng/aoroot/bin/TTCtrl -i ttctrl

startProcessByName(): starting process /home/AOeng/aoroot/bin/SimpleMotorCtrl -i adc1

startProcessByName(): starting process /home/AOeng/aoroot/bin/SimpleMotorCtrl -i adc2

startProcessByName(): starting process /home/AOeng/aoroot/bin/SimpleMotorCtrl -i rerotator

startProcessByName(): starting process /home/AOeng/aoroot/bin/SimpleMotorCtrl -i filterwheel1

startProcessByName(): starting process /home/AOeng/aoroot/bin/SimpleMotorCtrl -i filterwheel2

startProcessByName(): starting process /home/AOeng/aoroot/bin/SimpleMotorCtrl -i mercury

startProcessByName(): starting process /home/AOeng/aoroot/bin/SimpleMotorCtrl -i cubestage

startProcessByName(): starting process /home/AOeng/aoroot/bin/CopleyCtrl -i baysidex

startProcessByName(): starting process /home/AOeng/aoroot/bin/CopleyCtrl -i baysidey

startProcessByName(): starting process /home/AOeng/aoroot/bin/CopleyCtrl -i baysidez

startProcessByName(): starting process /home/AOeng/aoroot/bin/CameraLensCtrl -i cameralensctrl

startProcessByName(): starting process /home/AOeng/aoroot/bin/PicCtrlW2 -i picctrl

startProcessByName(): starting process /home/AOeng/aoroot/bin/OptLoopDiagnostic -i optloopdiag

startProcessByName(): starting process /home/AOeng/aoroot/bin/pupilcheck.py -i pupilcheckocam2 ocam2

-- Stage masterdiagnostic housekeeperWFS dbfiller

startProcessByName(): starting process /home/AOeng/aoroot/bin/MasterDiagnostic -i masterdiagnostic

startProcessByName(): starting process /home/AOeng/aoroot/bin/housekeeperWFS -i housekeeperWFS

startProcessByName(): starting process /home/AOeng/aoroot/bin/DBFiller -i dbfiller

-- Stage wfsarb

startProcessByName(): starting process /home/AOeng/aoroot/bin/WfsArbitrator -i wfsarb

-- Stage gopt

startProcessByName(): starting process /home/AOeng/aoroot/bin/gopt.py -i gopt

[AOeng@soul-dxwfs SOUL]$ w_check

msgdrtdb running

mirrorctrl running and connected to Msgd

pinger running and connected to Msgd

powerboard running and connected to Msgd

slopecompctrl running and connected to Msgd

techviewctrl running and connected to Msgd

ocam2 running and connected to Msgd

ccd47 running and connected to Msgd

ttctrl running and connected to Msgd

adc1 running and connected to Msgd

adc2 running and connected to Msgd

rerotator running and connected to Msgd

filterwheel1 running and connected to Msgd

filterwheel2 running and connected to Msgd

mercury running and connected to Msgd

cubestage running and connected to Msgd

baysidex running and connected to Msgd

baysidey running and connected to Msgd

baysidez running and connected to Msgd

cameralensctrl running and connected to Msgd

picctrl running and connected to Msgd

optloopdiag running and connected to Msgd

pupilcheckocam2 running and connected to Msgd

masterdiagnostic running and connected to Msgd

housekeeperWFS running and connected to Msgd

dbfiller running and connected to Msgd

wfsarb running and connected to Msgd

gopt running and connected to Msgd
  • POWER ON.
  • OCAM NO LIVE
  • Troubleshoot-> Power cycle BCU2K -> change binning 2x2 back to 1x1 cropped.
  • remote communicaiton laggish.
  • WFS Arbitrator process down.
  • it didn't start.
  • W-stop/start
  • Continous detach of the wfsarbitrator to msg deamon.
  • The process doesn't restart.
-bash: w-check: command not found
[AOeng@soul-dxwfs SOUL]$ w_check

msgdrtdb running
mirrorctrl running and connected to Msgd
pinger running and connected to Msgd
powerboard running and connected to Msgd
slopecompctrl running and connected to Msgd
techviewctrl running and connected to Msgd
ocam2 running and connected to Msgd
ccd47 running and connected to Msgd
ttctrl running and connected to Msgd
adc1 running and connected to Msgd
adc2 running and connected to Msgd
rerotator running and connected to Msgd
filterwheel1 running and connected to Msgd
filterwheel2 running and connected to Msgd
mercury running and connected to Msgd
cubestage running and connected to Msgd
baysidex running and connected to Msgd
baysidey running and connected to Msgd
baysidez running and connected to Msgd
cameralensctrl running and connected to Msgd
picctrl running and connected to Msgd
optloopdiag running and connected to Msgd
pupilcheckocam2 running and connected to Msgd
masterdiagnostic running and connected to Msgd
housekeeperWFS running and connected to Msgd
dbfiller running and connected to Msgd
wfsarb running but NOT connected to Msgd
gopt running and connected to Msgd

  • Alignment check with a dark chamber.
  • Alignment bin1,1000Hz,3l/D.EM=1.
  • Saved board setup alignment2
The camera lens in Y direction at -100 shows a pupil diff of 2.6 , for the X direction there is more range and has an error of 0.7.

The ocam2k shows that it requires time to de-charge, with the lights on the level of background was above 40K, when the lights when off it was observed that it was decharging the detector untill arrive to a few counts.
  • Saved a wfs frames. TN 20210414_234107.

frames_DX_april14.png
  • pwer off.
WfsArbitrator _83663|INF| 159|2021-04-14 23:49:43.888710| MAIN > Turning off PI_POWER
WfsArbitrator_83663|INF| 160|2021-04-14 23:50:13.891158| MAIN > Cannot turn off Tip Tilt Mirror. Reason: Timeout waiting for powerboard.R.PI_POWER.CUR - TIMEOUT_ERROR - GENERIC_SYS_ERROR

[AOeng@soul-dxwfs SOUL]$ w_check

terminate called after throwing an instance of 'Arcetri::LoggerFatalException'
Aborted (core dumped)
  • Check disk space.
[AOeng@soul-dxwfs 14]$ df

Filesystem 1K-blocks Used Available Use% Mounted on

/dev/mapper/vg00-root

        1. 5243744 503316 92% /

tmpfs 8108288 0 8108288 0% /dev/shm

/dev/sda1 194241 39707 144294 22% /boot

/dev/mapper/vg00-home

854305100 810885864 16384 100% /home

/dev/mapper/vg00-tmp 999320 4544 942348 1% /tmp

/dev/mapper/vg00-var 3997376 423832 3363832 12% /var

192.168.39.55:/local/aomeas

7750165504 4789786624 2569784320 66% /local/aomeas
  • [AOeng@soul-dxwfs 04]$ du -h
31M ./04

65G ./14

31M ./10

31M ./06

31M ./08

31M ./13

31M ./03

31M ./01

31M ./05

31M ./12

31M ./07

31M ./09

31M ./11
  • It generated about 65Gb.
  • remove the masterdiagnostic logs.
[AOeng@soul-dxwfs 14]$ du -h

762M .

-- JuanCarlosGuerra - 14 Apr 2021