Summary.

Set the shell shows a problem with the actuator 563. A call to Guido and Xianyu to check the system, file consistency check and it seems ok but actuator is still failiung. Set the actuator in the position list.

Set the shell shows another set of actuator with problems, changinf the reference wave from 1/8 to full didn't show the problems with the actuators. St the shell shows a that the actuator 202 shows a large force which avoid to have a good flat. Remove this acutaotor from position and restablish 563 as good. Rest/set the shell several times, flat of 638.
Pupil chekc for Bin1. The pupil Bin1 was observed last night with a large shift in positve Y direction. Startup of the system showed a bad two quadrants in the ocam. Power off/on.

Setting up the WFS for close loop, there is a laggish communicaiton and it takes too much time to open and execute the GUI fuctions. Run the rotation script test and it showed issues. align the PSF again, preset, test again with the same problems.

Move the rotator to 340,360 ajd pupil check, the pupil check Ok, at 240 shows to be at the limit, a further test neeeds to scan all the rotation ranges..

Details

WfsArbitrator _18710|INF| 40|2021-03-29 20:05:12.844376| WFS > Executing operate...

WfsArbitrator _18710|INF| 41|2021-03-29 20:05:12.844441| WFS > Python command: WfsArbScripts.setOperating(self, sensor = 'FLAOWFS', instr = '', config = 'WFS_complete_(with_ccd47)', boardSetup = '', opticalSetup = False)

WfsArbitrator _18710|INF| 42|2021-03-29 20:05:34.200028| MAIN > Sensor mode: FLAO

Mon Mar 29 20:07:40.441 2021 aos.info - FLAO: Adsec 672b-left shell set started.
Mon Mar 29 20:07:41.159 2021 aos.info - FLAO: MISFUNCTIONING CAPSENS: (ID:563-****um)
Mon Mar 29 20:07:41.177 2021 aos.AdsecSet.failed - AdsecSet [412] - SetFlatAo: FATAL - IDL An in-use actuator used is not working anymore

email Guido and Xianyu.

Xianyu restart the Adsec software.
  • Power off/On
  • Check Ocam2k bias.

Two quadrants shows to have a different bias. See image attached.

Screen Shot 2021-03-29 at 10.25.24_poweron.png
  • power off WFS
WfsArbitrator _18710|INF| 234|2021-03-29 20:25:42.854225| WFS > Executing off...

WfsArbitrator _18710|INF| 235|2021-03-29 20:25:42.854305| WFS > Python command: WfsArbScripts.setPowerOff(self, sensor = 'FLAOWFS', instr = '')
  • wfs_init
WfsArbitrator _82827|INF| 37|2021-03-29 20:30:39.859220| OPTLOOPDIAG > Executing enableAntiDrift(true)...

WfsArbitrator _82827|INF| 38|2021-03-29 20:30:39.859409| WFS > Executing operate...

WfsArbitrator _82827|INF| 39|2021-03-29 20:30:39.859478| WFS > Python command: WfsArbScripts.setOperating(self, sensor = 'FLAOWFS', instr = '', config = 'WFS_complete_(with_ccd47)', boardSetup = '', opticalSetup = False)

WfsArbitrator _82827|INF| 40|2021-03-29 20:31:00.950482| MAIN > Sensor mode: FLAO
  • ocam 2k good bias.
le = 0, zero = 1)

WfsArbitrator _82827|INF| 83|2021-03-29 21:33:46.049703| WFS > Executing presetAO...

WfsArbitrator _82827|INF| 84|2021-03-29 21:33:46.049849| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 10, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _82827|INF| 184|2021-03-29 21:47:58.863560| OPTLOOPDIAG > Executing enableAntiDrift(true)...

WfsArbitrator _82827|INF| 185|2021-03-29 21:47:58.863708| WFS > Python command: WfsArbScripts.updateNcpa(self, sensor = 'FLAOWFS', instr = 'LUCIFER', rotAngle = 0, zero = 1)

WfsArbitrator _82827|INF| 186|2021-03-29 21:47:58.874364| WFS > Executing presetAO...

WfsArbitrator _82827|INF| 187|2021-03-29 21:47:58.874496| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 10, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

  • The pupil alignment shows to have problems and it observed that the pupils are changing sizes..changing pupils sizes ??????
fsArbitrator_82827|INF| 644|2021-03-29 22:42:12.794057| MAIN > Camera lens tracking: moving by x= 10.0 y=-13.4 (um)

WfsArbitrator _82827|INF| 645|2021-03-29 22:42:13.903273| MAIN > Camera lens tracking: moving by x= 5.0 y= -5.8 (um)

WfsArbitrator _82827|INF| 646|2021-03-29 22:42:15.016170| MAIN > Camera lens tracking: moving by x= 4.7 y= -4.2 (um)

WfsArbitrator _82827|INF| 647|2021-03-29 22:42:16.126102| MAIN > Camera lens tracking: moving by x= 4.5 y= -3.0 (um)

WfsArbitrator _82827|INF| 648|2021-03-29 22:42:17.238412| MAIN > Camera lens tracking: moving by x= 7.9 y= -5.2 (um)

WfsArbitrator _82827|INF| 649|2021-03-29 22:42:18.353944| MAIN > Camera lens tracking: moving by x= 2.9 y= 0.5 (um)

WfsArbitrator _82827|INF| 650|2021-03-29 22:42:19.464387| MAIN > Camera lens tracking: moving by x= 4.9 y= -3.2 (um)

WfsArbitrator _82827|INF| 651|2021-03-29 22:42:20.583713| MAIN > Camera lens tracking: moving by x= 5.8 y= -3.0 (um)

WfsArbitrator _82827|INF| 652|2021-03-29 22:42:21.693730| MAIN > Camera lens tracking: moving by x= 4.6 y= -0.8 (um)

WfsArbitrator _82827|INF| 653|2021-03-29 22:42:22.803670| MAIN > Camera lens tracking: moving by x= 4.8 y= -1.4 (um)

WfsArbitrator _82827|INF| 654|2021-03-29 22:42:23.924686| MAIN > Camera lens tracking: moving by x= 3.8 y= -0.9 (um)

WfsArbitrator _82827|INF| 655|2021-03-29 22:42:25.037432| MAIN > Camera lens tracking: moving by x= 4.1 y= 0.0 (um)

WfsArbitrator _82827|INF| 656|2021-03-29 22:42:26.148016| MAIN > Camera lens tracking: moving by x= 9.3 y= 5.0 (um)

WfsArbitrator _82827|INF| 657|2021-03-29 22:42:27.256941| MAIN > Camera lens tracking: moving by x= -0.5 y= -2.7 (um)

WfsArbitrator _82827|INF| 658|2021-03-29 22:42:28.369706| MAIN > Camera lens tracking: moving by x= 10.4 y= 5.9 (um)

WfsArbitrator _82827|INF| 659|2021-03-29 22:42:29.494525| MAIN > Camera lens tracking: moving by x= 4.4 y= 43.5 (um)

WfsArbitrator _82827|INF| 660|2021-03-29 22:42:30.674485| MAIN > Camera lens tracking: moving by x= -0.3 y= 22.8 (um)

WfsArbitrator _82827|INF| 661|2021-03-29 22:42:32.523311| MAIN > Camera lens tracking: moving by x=-79.8 y=103.7 (um)

WfsArbitrator _82827|INF| 662|2021-03-29 22:42:42.767513| MAIN > Camera lens tracking: moving by x=-53.0 y= 73.1 (um)

WfsArbitrator _82827|INF| 663|2021-03-29 22:42:52.989116| MAIN > Camera lens tracking: moving by x=-28.8 y= 81.6 (um)

WfsArbitrator _82827|INF| 664|2021-03-29 22:42:57.550938| WFS > Executing stopLoop...

WfsArbitrator _82827|INF| 665|2021-03-29 22:42:57.551031| WFS > Python command: WfsArbScripts.stopLoop(self, sensor = 'FLAOWFS', instr = 'LUCIFER')

WfsArbitrator _82827|INF| 666|2021-03-29 22:42:57.555453| WFS > Command returns success .

WfsArbitrator _82827|INF| 667|2021-03-29 22:42:57.555492| MASTDIAGN > Setting master diagnostic in open loop mode

WfsArbitrator _82827|INF| 668|2021-03-29 22:42:57.655980| COMMANDHANDLER > FSM (status: AOSet) has received command 2033 (StopLoopAdsec)

WfsArbitrator _82827|INF| 669|2021-03-29 22:42:57.657421| ADSEC > Executing openLoop...

WfsArbitrator _82827|INF| 670|2021-03-29 22:42:57.657464| ADSEC > Requesting StopAo to AdSecArbitrator...

WfsArbitrator _82827|INF| 671|2021-03-29 22:42:58.774660| COMMANDHANDLER > Command StopLoopAdsec (code 2033) successfully completed

WfsArbitrator _82827|INF| 672|2021-03-29 22:42:58.775372| WFS > Executing stopLoop...

WfsArbitrator _82827|INF| 673|2021-03-29 22:42:58.775454| WFS > Python command: WfsArbScripts.stopLoop(self, sensor = 'FLAOWFS', instr = 'LUCIFER')

WfsArbitrator _82827|INF| 674|2021-03-29 22:42:58.776642| WFS > Command returns success .

WfsArbitrator _82827|INF| 675|2021-03-29 22:42:58.776688| MASTDIAGN > Setting master diagnostic in open loop mode

WfsArbitrator _82827|INF| 676|2021-03-29 22:42:58.877176| COMMANDHANDLER > FSM (status: AOSet) has received command 2033 (StopLoopAdsec)

WfsArbitrator _82827|INF| 677|2021-03-29 22:42:58.877822| ADSEC > Executing openLoop...

WfsArbitrator _82827|INF| 678|2021-03-29 22:42:58.877865| ADSEC > Requesting StopAo to AdSecArbitrator...

WfsArbitrator _82827|INF| 679|2021-03-29 22:43:00.233395| COMMANDHANDLER > Command StopLoopAdsec (code 2033) successfully completed

........

le = 0, zero = 1)

WfsArbitrator _82827|INF| 689|2021-03-29 22:45:29.612401| WFS > Executing presetAO...

WfsArbitrator _82827|INF| 690|2021-03-29 22:45:29.612535| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 10, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

  • issue executing the rotation script..Email to Fabio

[AOeng@soul-sxwfs scripts]$ wobble_test_backward.py
Traceback (most recent call last):
File "/home/AOeng/aoroot.latest/bin/wobble_test_backward.py", line 15, in <module>
g = adsec.get_gains()
File "/home/AOeng/aoroot.latest/lib/python/AdOpt/asm.py", line 71, in get_gains
return fits_lib.readSimpleFits(gainpath)
File "/home/AOeng/aoroot.latest/lib/python/AdOpt/fits_lib.py", line 87, in readSimpleFits
fitsobj = pyfits.open(filename, ignore_missing_end=True)
File "/usr/lib64/python2.6/site-packages/pyfits/core.py", line 10729, in open
ffo = _File(name, mode=mode, memmap=memmap, **parms)
File "/usr/lib64/python2.6/site-packages/pyfits/core.py", line 9268, in __init__
raise e
%BROWN%IOError: [Errno 2] No such file or directory: '/local/aomeas/adsec_calib/M2C/p/LNgains.fits'

WfsArbitrator _82827|INF| 1063|2021-03-29 23:17:41.066812| COMMANDHANDLER > FSM (status: AOSet) has received command 2005 (Off)

WfsArbitrator _82827|INF| 1064|2021-03-29 23:17:41.067088| OPTLOOPDIAG > Executing enableAntiDrift(false)...

WfsArbitrator _82827|INF| 1065|2021-03-29 23:17:41.067192| WFS > Executing off..

23:20 STOP