Summary

Performance check for bin1, bin3 and bin4. loop stable and optimize gain and gopt worked. The PSF at bin3 shows an elongation.. to be analysied.

bin1 shows a good corrected PSf with SR in H band 73%., for bin3 and bin4 is required to use the J band filter and exposure of 3.To be updated in the procedure Luci close loop check.

Bin4 rotation check only one pass 400 to zero.

Details

  • power on.-> OK
  • OCAM shows the triangle feature"
  • taken frames for analysis...20210323_174606
  • power cycle bcu2k and set bin2 from ocam2k HW gui.
  • Back to life and normal bias.
  • AOS gui. it can't change parameters in the AOScomm gui, the edit boxes comes back to the current values.
  • TCSGUI ->aos stop/start
Automatic close loop

WfsArbitrator _19630|INF| 197|2021-03-23 18:41:50.313590| MAIN > Camera lens tracking: moving by x= -0.8 y= 1.7 (um)

WfsArbitrator _19630|WAR| 198|2021-03-23 18:41:52.069929| WFS > Command returns retryable error : RETRY: Gopt did not stabilize within 10 iterations (-5001) TIMEOUT_ERROR

WfsArbitrator _19630|INF| 199|2021-03-23 18:41:52.650058| MAIN > Camera lens tracking: moving by x= 1.4 y= -0.5 (um)

WfsArbitrator _19630|INF| 200|2021-03-23 18:41:57.264121| MAIN > Camera lens tracking: moving by x= 0.1 y= -1.0 (um)

TN:
  • _184246
  • 20210323_184337
taking Luci darks. but I don;t see any PSF in the Field of N30. it could be offaxis???.
This is due to the filter..

WfsArbitrator _19630|INF| 438|2021-03-23 19:04:02.645776| COMMANDHANDLER > FSM (status: AOSet) has received command 2033 (StopLoopAdsec)

WfsArbitrator _19630|INF| 445|2021-03-23 19:13:30.183265| WFS > Python command: WfsArbScripts.updateNcpa(self, sensor = 'FLAOWFS', instr = 'LUCIFER', rotAngle = 0, zero = 1)

RESTART THE PROCESS AUXLOOP

WfsArbitrator _19630|INF| 446|2021-03-23 19:13:30.195250| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 447|2021-03-23 19:13:30.195371| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 10, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _19630|INF| 448|2021-03-23 19:13:30.196313| MAIN > LUT Applied: Rota

WfsArbitrator _19630|INF| 439|2021-03-23 19:04:02.646631| ADSEC > Executing openLoop...

optimize gain.. failed due to a jump in the actuator #164... safe skipp triggered.

repeat the optmize gain->OK

gopt->ok

TN
  • 20210323_193045
  • _193059
MOVING TO H BAND LUCI.. PSF VISIBLE.

REFERENCE IMAGE CL 20210324.0010

WfsArbitrator _19630|INF| 894|2021-03-23 19:45:36.236944| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 10, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _19630|INF| 895|2021-03-23 19:45:36.237895| MAIN > LUT Applied: Rota

OPTIMIZE GAIN.

TN:
  • 20210323_195412
    0.733088
  • bin1_march23_s0.8.png
  • _195527
GOPT on
  • _195808
  • _195946
NCPA on

_200106

launch optimize gain in a cl;optimize gain

gopt ->ok
  • _200436

psf_200436.png
  • _200556
    SR=83%

BIN3

WfsArbitrator _19630|INF| 1293|2021-03-23 20:11:50.562078| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 15, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)
  • optimize gain->ok
  • loop open.. skip frames. option to reclose from flao gui
  • optimize gain->ok
  • change luci integration time to 3 from the variable inspector
TN
  • _202600
hard to see the PSF

change filter to J
  • _202756
taking Luci dark
  • _203325
  • BIN3_MARCH23_S0.8.png
  • _203451

BIN4

  • shutter 46
WfsArbitrator _19630|INF| 1533|2021-03-23 20:40:20.691757| WFS > Python command: WfsArbScripts.updateNcpa(self, sensor = 'FLAOWFS', instr = 'LUCIFER', rotAngle = 0, zero = 1)

WfsArbitrator _19630|INF| 1534|2021-03-23 20:40:20.702650| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 1535|2021-03-23 20:40:20.702772| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 16.3, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)
  • adjust the light source to 17.
  • disturbance 200Hz, s1.6
WfsArbitrator _19630|INF| 1563|2021-03-23 20:45:45.070982| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 1564|2021-03-23 20:45:45.071096| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 17, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

move the stage negaitve moves up in the CCD47

open shutter full to identify the psf on the CCD47

reduce to 45, freq 315 mag 16.5, bin4

optimize gain->OK

TN
  • _205643
  • _210002
BIN4_MARCH23_S1.png

  • _210128
bin4_march23_modalplot.png

open loop

disturbance s2.0

WfsArbitrator _19630|INF| 1733|2021-03-23 21:06:27.913888| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 1734|2021-03-23 21:06:27.914071| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 17, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

TN
  • _211412
bin4_s2p2_modalplot.png
  • _211556
  • _211743
BIN4_MARCH23_S1.png

renormalize the loops gains
  • _212002

BIN4 TTM

WfsArbitrator _19630|INF| 1895|2021-03-23 21:23:47.700519| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 1896|2021-03-23 21:23:47.700639| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'TTM-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 17, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _19630|INF| 1897|2021-03-23 21:23:47.701470| MAIN > LUT Applied: Rot

PUPIL BIN4 TTM->20200916_173857

same as ace-ao

BIN 4 ACE-AO

preset ace-ao

WfsArbitrator _19630|INF| 1981|2021-03-23 21:34:10.627246| WFS > Python command: WfsArbScripts.updateNcpa(self, sensor = 'FLAOWFS', instr = 'LUCIFER', rotAngle = 0, zero = 1)

WfsArbitrator _19630|INF| 1982|2021-03-23 21:34:10.636587| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 1983|2021-03-23 21:34:10.636699| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 17, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _19630|INF| 1984|2021-03-23 21:34:10.637547| MAIN > LUT Applied: Ro

bin4_ace_optgain_ok.png

bin4_ace-ao_pup.png buin4_ace-ao_puperr.png

TN
  • _214158

NO PROBLEM CLOSING LOOP,. NO SKIP FRAMES

BIN4-TTM

WfsArbitrator _19630|INF| 2081|2021-03-23 21:44:33.519703| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 2082|2021-03-23 21:44:33.519815| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'TTM-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 17, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

SKIP FRAMES..

optimize gain ->LOOP OPEN DUE SKIP FRAMES.

reclose when the process failed.

lngain: tn
  • _215144
gain:tt0.5ho1=0.1 ho2:0.05

gian:0.80,ho1:0.2
  • _215533

ROTATION CHECK BIN 4

  • cd SOUL/scripts/
  • MOVE ROT TO 440
WfsArbitrator _19630|INF| 2247|2021-03-23 22:03:36.653412| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 2248|2021-03-23 22:03:36.653536| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 17, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _19630|INF| 2249|2021-03-23 22:03:36.654397| MAIN > LUT Applied: R

stop at 420..

new preset.

WfsArbitrator _19630|INF| 2375|2021-03-23 22:19:51.748123| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 2376|2021-03-23 22:19:51.748239| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 17, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _19630|INF| 2377|2021-03-23 22:19:51.749105| MAIN > LUT Applied: Rot

LOOP OPEN AT 420.

WfsArbitrator _19630|INF| 2375|2021-03-23 22:19:51.748123| WFS > Executing presetAO...

WfsArbitrator _19630|INF| 2376|2021-03-23 22:19:51.748239| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 17, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

WfsArbitrator _19630|INF| 2377|2021-03-23 22:19:51.749105| MAIN > LUT Applied: Rot

BIN4_PUP_POS_MARCH23.png BIN4_PUP_ERR_MARCH23_ROT.png

22:54 STOP

fsArbitrator_19630|INF| 3071|2021-03-23 22:54:06.280091| COMMANDHANDLER > FSM (status: AOSet) has received command 2043 (setSafe)

WfsArbitrator _19630|INF| 3072|2021-03-23 22:54:06.280138| WFS > Executing setSafe...

OCAM SAFE ->OK

PSF->ENABLE OK

ROT POSITION->5, 341

SHELL REST->OK

disable_rr mode ->ok

[AOeng@sxadsec ~]$ disable_rr_mode.sh

THRDTEST: 6.15 64b [TH](Built: Jan 20 2021 20:18:53) - Dbg lev.:0, quiet, Line edit & history:Yes

Trying to connect to MsgD @ 127.0.0.1:9752

THRDTEST cmd: write AOARB.L.RR_ENABLED i 0

THRDTEST cmd: quit

-- JuanCarlosGuerra - 23 Mar 2021
I Attachment Action Size Date Who Comment
BIN3_MARCH23_S0.8.pngpng BIN3_MARCH23_S0.8.png manage 45 K 23 Mar 2021 - 23:15 JuanCarlosGuerra  
BIN4_MARCH23_S0.8.pngpng BIN4_MARCH23_S0.8.png manage 52 K 23 Mar 2021 - 23:18 JuanCarlosGuerra  
BIN4_MARCH23_S1.pngpng BIN4_MARCH23_S1.png manage 52 K 23 Mar 2021 - 23:20 JuanCarlosGuerra  
BIN4_PUP_ERR_MARCH23_ROT.pngpng BIN4_PUP_ERR_MARCH23_ROT.png manage 80 K 23 Mar 2021 - 23:25 JuanCarlosGuerra  
BIN4_PUP_POS_MARCH23.pngpng BIN4_PUP_POS_MARCH23.png manage 61 K 23 Mar 2021 - 23:23 JuanCarlosGuerra  
bin1_march23_s0.8.pngpng bin1_march23_s0.8.png manage 48 K 23 Mar 2021 - 23:12 JuanCarlosGuerra  
bin4_ace-ao_pup.pngpng bin4_ace-ao_pup.png manage 75 K 23 Mar 2021 - 21:42 JuanCarlosGuerra  
bin4_ace_optgain_ok.pngpng bin4_ace_optgain_ok.png manage 214 K 23 Mar 2021 - 21:42 JuanCarlosGuerra  
bin4_march23.pngpng bin4_march23.png manage 49 K 24 Mar 2021 - 19:59 JuanCarlosGuerra  
bin4_march23_enceng.pngpng bin4_march23_enceng.png manage 51 K 24 Mar 2021 - 20:02 JuanCarlosGuerra  
bin4_march23_modalplot.pngpng bin4_march23_modalplot.png manage 103 K 24 Mar 2021 - 20:21 JuanCarlosGuerra  
bin4_s2p2_modalplot.pngpng bin4_s2p2_modalplot.png manage 69 K 23 Mar 2021 - 21:15 JuanCarlosGuerra  
buin4_ace-ao_puperr.pngpng buin4_ace-ao_puperr.png manage 100 K 23 Mar 2021 - 21:42 JuanCarlosGuerra  
psf_200436.pngpng psf_200436.png manage 48 K 23 Mar 2021 - 20:15 JuanCarlosGuerra  