Close Loop check and pupil mask rotation checks

Staff:

LBTO: Juan Carlos

Arcetri:none

Summary

Checking the close loop after Arcetri software upgrade of message daemons and roll back to default SW. The close loop in automatic mode for Bin1 and Bin3 didn't show any problems, The test was done without disturbance.
Adsec didn;t show any problems.

Acquisiton of pupil rotation data for Bin3 to compare.

Details

  • POwer on WFS->OK
    Ocam ambient Ok
  • Adsec flat ->ok
    flat #639 modes.

Bin 1.

  • Argos cal unit shutter open fully.
AOS PRESETAO

WfsArbitrator _124046|INF| 51|2021-03-08 21:14:10.921985| WFS > Executing presetAO...
WfsArbitrator_124046|INF| 52|2021-03-08 21:14:10.922078| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 7.51, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)

PRESET CANCEL from FLAOGUI

System status:
  • wfs->AOPREPARED.
  • aoARBITRATOR->AOArbitrator.Ready
fsArbitrator_124046|INF| 77|2021-03-08 21:23:14.696904| WFS > Executing calibrateHODark...
WfsArbitrator_124046|INF| 78|2021-03-08 21:23:14.696960| WFS > Python command: WfsArbScripts.calibHODark(self, sensor = 'FLAOWFS', instr = 'LUCIFER', num = 100)
WfsArbitrator_124046|INF| 79|2021-03-08 21:23:21.492885| WFS > Command returns success .
WfsArbitrator_124046|INF| 80|2021-03-08 21:23:21.492947| COMMANDHANDLER > Command CalibrateHODark (code 2014) successfully completed
WfsArbitrator_124046|INF| 81|2021-03-08 21:23:29.567048| COMMANDHANDLER > FSM (status: AOPrepared) has received command 2018 (CalibrateTVDark)
WfsArbitrator_124046|INF| 82|2021-03-08 21:23:29.567133| WFS > Executing calibrateTVDark...
WfsArbitrator_124046|INF| 83|2021-03-08 21:23:29.567205| WFS > Python command: WfsArbScripts.calibTVDark(self, sensor = 'FLAOWFS', instr = 'LUCIFER', num = 10)

TV dark->20210308_212405

WfsArbitrator _124046|INF| 180|2021-03-08 21:40:09.720748| WFS > Executing presetAO...
WfsArbitrator_124046|INF| 181|2021-03-08 21:40:09.720861| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 7.51, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)
  • AO automatic mode.
  • No disturbance applied.
  • TRnumber #20210308_214628
  • Aux loops->ok

AUTOMATIC CLOSE LOOP OK

BIN3


WfsArbitrator_124046|INF| 441|2021-03-08 21:58:04.479796| WFS > Python command: WfsArbScripts.presetAO(self, sensor = 'FLAOWFS', instr = 'LUCIFER', mode = 'ACE-AO', starxpos = -0, starypos = 0, telElevation = 0, derotAngle = 0, starMag = 15.3, starColor = 0, r0 = 0, badseeing = 0, v0 = 0)
WfsArbitrator_124046|INF| 442|2021-03-08 21:58:04.480686| MAIN > LUT Applied: Rotang Ele X_LUT Y_LUT X_Enc Y_Enc X_Enc Y_Enc X_Tot Y_Tot
WfsArbitrator_124046|INF| 443|2021-03-08 21:58:04.480728| MAIN > LUT Applied: deg deg V V mm mm V V V V
WfsArbitrator_124046|INF| 444|2021-03-08 21:58:05.217116| MAIN > LUT Applied: Rotang Ele X

AUTOMATIC CLOSE LOOP OK.

BIN 3 PUPIL ROTATION.
  • mag 15.4
  • Argos shutter 49.

bin3_day_mar8.png

bin3_error_mar08.png

DOWN

bin3_err_mar8_down.png

UP

  • PUPIL ERROR >0.2 FROM 312 - 380 ROTATOR MECHANICAL POSITION.
bin3_err_mar8_UP.png

22:52 STOP

-- JuanCarlosGuerra - 08 Mar 2021
Topic revision: r1 - 08 Mar 2021, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.