20210215 Daytime tests for bin 3,4 and collect NCPA

Connected: Doug,Juan Carlos, Xianyu

System Startup

Juan Carlos had a lagging connection,the WFS setup and deploy Argos calibration unit assisted by Doug.

15:28 wfs_init
  • Failed trying to power on cube rotator
  • Should not happen in default startup, ie startup for nighttime operation.
WfsArbitrator _117216|INF|        38|2021-02-15 15:28:32.478916|              WFS > Executing operate...
WfsArbitrator _117216|INF|        39|2021-02-15 15:28:32.478987|              WFS > Python command: WfsArbScripts.setOperating(self, sensor = 'FLAOWFS', instr = '', config = 'WFS_complete_(with_ccd47)', boardSetup = '', opticalSetup = False)
WfsArbitrator _117216|INF|        40|2021-02-15 15:28:51.069645|             MAIN > Sensor mode: FLAO
WfsArbitrator _117216|INF|        41|2021-02-15 15:31:06.419289|              WFS > Python command: WfsArbScripts.updateModulation(self, sensor = 'FLAOWFS', instr = '', freq = 2000)
WfsArbitrator _117216|ERR|        42|2021-02-15 15:34:59.310508|              WFS > Command returns error : Timeout waiting for mercury.L.STATUS (-5001) TIMEOUT_ERROR
WfsArbitrator _117216|INF|        43|2021-02-15 15:34:59.310609|   COMMANDHANDLER > Command execution failed: Fsm forced to Failure
WfsArbitrator _117216|ERR|        44|2021-02-15 15:34:59.310671|             MAIN > Operate: FATAL - Timeout waiting for mercury.L.STATUS (-5001) TIMEOUT_ERROR
WfsArbitrator _117216|INF|        45|2021-02-15 15:34:59.313313|              WFS > Python command: WfsArbScripts.updateModulation(self, sensor = 'FLAOWFS', instr = '', freq = 1000)
WfsArbitrator _117216|INF|        46|2021-02-15 15:34:59.315776|              WFS > Python command: WfsArbScripts.updateModulation(self, sensor = 'FLAOWFS', instr = '', freq = 2000)
WfsArbitrator _117216|INF|        47|2021-02-15 15:34:59.318281|              WFS > Python command: WfsArbScripts.updateModulation(self, sensor = 'FLAOWFS', instr = '', freq = 1000)

WfsArbitrator _117217|INF|       104|2021-02-15 15:33:35.903621|             MAIN > Setting up cube
WfsArbitrator _117217|INF|       105|2021-02-15 15:33:35.904307|             MAIN > Turning on cubestage
WfsArbitrator _117217|INF|       106|2021-02-15 15:33:35.936184|             MAIN > Turning on cuberot
WfsArbitrator _117217|INF|       107|2021-02-15 15:34:59.310134|             MAIN > Timeout waiting for mercury.L.STATUS - TIMEOUT_ERROR

16:05 power on sucessful.
  • cuberotator powered on and homed
  • cubestage powered on and home

17:42 Loop close with not seeing disturbance

WfsArbitrator _169714|INF|       408|2021-02-15 17:45:20.951715|             MAIN > HO1: range  0.10 -  0.60
WfsArbitrator _169714|INF|       409|2021-02-15 17:45:21.170355|             MAIN > Received exception with code -10045
WfsArbitrator _169714|ERR|       410|2021-02-15 17:45:21.170470|             MAIN > Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
WfsArbitrator _169714|DEB|       411|2021-02-15 17:45:21.171105|             MAIN > arbFunc doStopLoop (, 'FLAOWFS', 'LUCIFER')

18:05 Loop closed, bin 3
  • WFS mag 14.7
  • GOPT value was still at 0.6 from the bin 1 closed loop
  • Has done a StartAO and the StopAO but ratio remained
  • Maually set GOPT to 1.0 and turned off two click buttions (apply to ...)
  • Optimze gain only do TT and HO1 in first round and then only TT for second. Why not HO2?

18:00 JC start SOUL/scripts/wobble_test_backwards.py (or _forwads.py) * get saturation from +160 to 280 in X on plot * get saturation from 340 to 400 in Y in plot

bin3cameralens_vs_rot.png

Check bin4.

backward/forward/backward.
Observed that at rotation zero, the two sets reached different positions. Minimum value reached in Y is -96mm

1st set rotation 0 cl_X[mm]=-14 cl_Y[mm]=-14
2nd set rotation 0 cl_X[mm]=-44 cl_Y[mm]=-45


bin4camerallens_vs_rot2.png

Optimize Gain for bin 4 is not working. Poor fit to TT.
  • bin_4_optimize_1.jpg:
    bin_4_optimize_1.jpg
  • bin_4_optimize_2.jpg:
    bin_4_optimize_2.jpg
  • bin_4_optimize_3.jpg:
    bin_4_optimize_3.jpg

Check bin1.

forward/backward.
from 440 to 0:
Rot 220 y -100
Rot 200 to 165 x -100
bin1cameralens_vs_rot.png

Check bin2.

forward/backward.
saturation showed at
320 to 400 y(-100)
340 to 220 y(-100)

bin2cameralens_vs_rot.png

21:21 Open bin 2 loop and apply flat. Hugh amount of coma on LUCI
  • luci1.20210216.0002.fits

luci1 dark 3 22

22

-- DougMiller - 15 Feb 2021
I Attachment Action Size Date Who Comment
bin1cameralens_vs_rot.pngpng bin1cameralens_vs_rot.png manage 277 K 15 Feb 2021 - 20:22 JuanCarlosGuerra  
bin2cameralens_vs_rot.pngpng bin2cameralens_vs_rot.png manage 279 K 15 Feb 2021 - 21:20 JuanCarlosGuerra  
bin3cameralens_vs_rot.pngpng bin3cameralens_vs_rot.png manage 217 K 15 Feb 2021 - 18:47 JuanCarlosGuerra  
bin4camerallens_vs_rot2.pngpng bin4camerallens_vs_rot2.png manage 305 K 15 Feb 2021 - 19:46 JuanCarlosGuerra  
bin_4_optimize_1.jpgjpg bin_4_optimize_1.jpg manage 59 K 16 Feb 2021 - 05:14 DougMiller  
bin_4_optimize_2.jpgjpg bin_4_optimize_2.jpg manage 54 K 16 Feb 2021 - 05:14 DougMiller  
bin_4_optimize_3.jpgjpg bin_4_optimize_3.jpg manage 77 K 16 Feb 2021 - 05:14 DougMiller  
Topic revision: r6 - 16 Feb 2021, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback