20210108 OSCO + INAF Full AO, but clouds move in

00:45 Start OSCO
  • Many failures
  • WFS Masterdiagnositics died 4 times (at least)
  • AdSec went into failure while Close Loop Step
  • See log snipets below

Sat Jan  9 01:13:43 UTC 2021  MasterDiag on WFS stop.  restart

Sat Jan  9 01:15:01 UTC 2021  Again

Sat Jan  9 01:15:01 UTC 2021

AdSecArbitrator_127396|INF|      3009|2021-01-09 01:16:50.877723|            MAIN > Received cmd: StopAo(0)
AdSecArbitrator_127396|INF|      3010|2021-01-09 01:16:50.877788|  COMMANDHANDLER > FSM (status: Failure) has received command 2015 (Stop Ao)
AdSecArbitrator_127396|ERR|      3011|2021-01-09 01:16:50.877815|  COMMANDHANDLER > adsecarb: Fsm is discarding command 2015 (Stop Ao)...
AdSecArbitrator_127396|WAR|      3012|2021-01-09 01:16:50.877929|            MAIN > StopAo: WARNING - adsecarb:Illegal command for state Failure (Stop Ao)
AdSecArbitrator_127396|ERR|      3013|2021-01-09 01:16:51.315667|    ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_127396|ERR|      3014|2021-01-09 01:16:51.315702|    ALERTHANDLER > Alert message: COILS DISABLED from housekeeper.L
20210901 01:16:51.3165 Alert: Error: COILS DISABLED
AdSecArbitrator_127396|ERR|      3015|2021-01-09 01:16:51.701993|    ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_127396|ERR|      3016|2021-01-09 01:16:51.702036|    ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
20210901 01:16:51.7028 Alert: Error: COILS DISABLED
AdSecArbitrator_127396|INF|      3017|2021-01-09 01:16:52.652972|    ALERTHANDLER > Received from masterdiagnostic.L a DumpSaved alert with filename /local/aolog/2021/01/09/ADAPTIVE-SECONDARY_00001610155012_20210109_011652.bin
AdSecArbitrator_127396|INF|      3018|2021-01-09 01:16:52.652994|    ALERTHANDLER > Processdump is skipped
20210901 01:16:52.6537 Alert: DumpSaved: DumpSaved vector ready

Recover fail work.  Set

Center Pupil   Master Diag process dies

AUX Loops died twice.

-- DougMiller - 09 Jan 2021
Topic revision: r1 - 09 Jan 2021, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback