Staff:

LBTO:JUan Carlos

Arcetri: Enrico et al.

Details.

Flat->440 mode.

22-06-07 14:59:38.559381| MAIN > the limiting actuator is-> # 44

Shell rest/Set

15:06:40.732020| MAIN > Maximum mode index used to apply flat -> # 630

taking a TV dark.

Spot in the CCD47
  • Check moving the hexapod Rx or Ry a fre arcseconds to check the spot movement
  • spot doesn't move. internal reflection of cube.
  • The source light is turn on from the PDU interface.
lbti_pdu.png
  • Executing hexa_spiral
IDL> print,hexa_spiral(300e-6,15,/apply)
Final HP bounding box =
-6.5000019 2.2300642 -1.0300146 56.069473 -383.96460
-6.5000019 2.2300642

hexaspiral_20220607_RR_lbti.png

8:50AM
  • Abort spiral ..spot not found
  • shift RX by +200 " end positions Rx=176
  • Starting spiral
Stop spiral.

9:04 AM
  • Home Mirror M3.
  • home selector.
Starting spiral from nominal positions.

9:20AM

Stop spiral no spot..

Thinking ..if we have the RR cup installed.

9:30am
  • checking for the protective cup in the RR.
  • Telescope at horizon

9:55 am telescope at zenith

16:55:03.215257| MAIN > Maximum mode index used to apply flat -> # 630
  • Not protective cup installed.
10:02 AM
  • Init the hexapod.

small pupils

ho1->0.05 to have a better pupils.

20220607_174713

moving the cub

improve the pupil dimensions..

now , ho2 can be closed with 0.05

_175346

flat saved:

default_20220607_500m.sav

change WFS

900,3l/D,300

_180550

cl_20220607_adsec.png
  • dsp 340,341
  • to be checked...
Inmat_acquired.

second iteration

actuator inner ring.

act_inner_ring_20220607.png

Inmat acquired.

flat 20220607_500nm.sav

loads

19:00:09.055841| MAIN > the limiting force is: 2.96459E-01
idl_65290 |INF| 11544|2022-06-07 19:00:09.055961| MAIN > Maximum mode index used to apply flat -> # 493
idl_65290 |INF| 11545|2022-06-07 19:00:09.056011| MAIN > the limiting actuator is-> # 216

analysisng from Arcetri the intmat

close the loop

to offload some small TT.

open loop

> Modes out of safe range ID: #149

close loop with new rec:20220607_190028

_191045

Check with AOS.

Tue Jun 7 19:15:39.368 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[34] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Jun 7 19:15:39.419 2022 aos.info - WFS source set to: LBTIWFS
Tue Jun 7 19:15:39.469 2022 aos.PresetAO{FLAO}.failed - PresetAO{FLAO}[34] - [AOException] presetAO: FATAL - [Errno 2] No such file or directory: '/local/aomeas/adsec_calib/M2C/KL_v29/RECs/Rec_20220606_190028.fits'

Tue Jun 7 19:16:25.756 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[35] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Jun 7 19:16:25.770 2022 aos.info - WFS source set to: LBTIWFS
Tue Jun 7 19:16:25.811 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq900.00_sd3892.fits
Tue Jun 7 19:16:26.557 2022 aos.info - FLAO: WFS: loading setup for LBTI

skip frames in the second pass for HO1.

close loop

dist on.

gopton

_192406,_192439,_192504,_192535,_192607,_192705,_192733,_192751,_192823

_192248

Acquire bin2 intmat.

12:46am

close loop bin2

_195624,_195653

MANUAL GAIN:

_201005,_201020,_201107

_201222,_201237,_201253

1:17 PM stop

-- JuanCarlosGuerra - 07 Jun 2022
Topic revision: r1 - 07 Jun 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.