Cloud Watching, er, Soul Science

01:12
  • Heading for the first target. 20:14:26.7 +41:13:30
  • OCAM went "Not Live", cycled masterdiagnostic. That got the OCAM back, but then no step would work on the preset.
    2020-11-04 01:24:19.167384| -13006 - [AOException] RETRY: Error in acquire ref: Attaching to shared buffer masterdiagnostic.L:OPTLOOPBUF - SLOT_NOT_FOUND_ERROR (-1000) GENERIC_SYS_ERROR
    2020-11-04 01:24:36.770511| -13006 - Illegal command for state ManualAcquire
    2020-11-04 01:25:02.408232| -13006 - [AOException] centerPupils: FATAL - Attaching to shared buffer masterdiagnostic.L:OPTLOOPBUF (-3508) SLOT_NOT_FOUND_ERROR
    2020-11-04 01:25:17.176617| Command canceled
    2020-11-04 01:27:31.929389| -13006 - [AOException] centerPupils: FATAL - Attaching to shared buffer masterdiagnostic.L:OPTLOOPBUF (-3508) SLOT_NOT_FOUND_ERROR
    2020-11-04 01:28:05.530025| -13006 - [AOException] centerPupils: WARNING - RETRY: CenterPupils command must be executed after a PresetAO command (0) NO_ERROR
    2020-11-04 01:28:14.632052| -13006 - [AOException] centerStar: WARNING - RETRY: AcquireRef command must be executed after a PresetAO command (0) NO_ERROR
    2020-11-04 01:28:52.461918| -13006 - [AOException] centerStar: WARNING - RETRY: AcquireRef command must be executed after a PresetAO command (0) NO_ERROR
    2020-11-04 01:29:27.500075| Command canceled
    2020-11-04 01:31:40.789630| -13006 - [AOException] centerPupils: FATAL - Attaching to shared buffer masterdiagnostic.L:OPTLOOPBUF (-3508) SLOT_NOT_FOUND_ERROR

  • Had to cycle all processes
  • 4th preset is the charm
  • GOPT on, NCPA on, bin3 891 Hz.
  • 20201104_014609, 20201104_014815, 20201104_015048, 20201104_015119, 20201104_015433
  • Doing a standard
02:32
  • Same target Br(gamma)
  • 20201104_024234, 20201104_024304, 20201104_024331, 20201104_024413, 20201104_024502
03:39
  • New preset to G1. Need pointing check
  • WfsArbitrator_159098|WAR| 1151|2020-11-04 03:41:23.533442| WFS > Command returns retryable error : RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND
    WfsArbitrator_159098|INF| 1152|2020-11-04 03:41:23.533521| COMMANDHANDLER > Command not executed (status RETRY) (errstr RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND)
    WfsArbitrator_159098|WAR| 1153|2020-11-04 03:41:23.533571| MAIN > centerStar: WARNING - RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND

  • 20201104_035257, 20201104_035330, 20201104_035352, 20201104_035416, 20201104_035436
04:14
  • It has been doing some safe skipping on offsets, like the loop resumes before the offset is quite finished.
  • The loop lost the guide star, but it was still running.
04:22
  • re-sending the preset
04:30
  • Running again.
  • 20201104_043105, 20201104_043148, 20201104_043213, 20201104_043239, 20201104_043305
  • 20201104_045602, 20201104_045636, 20201104_045656, 20201104_045718, 20201104_045744
  • 20201104_050932, 20201104_050955, 20201104_051020, 20201104_051109, 20201104_051149
  • 20201104_054859, 20201104_054925, 20201104_054949, 20201104_055013, 20201104_055038
06:03
  • Cloud made the loop open and the shell ripped, for some reason.
  • 20201104_060834, 20201104_060915, 20201104_060941, 20201104_060959, 20201104_061035
  • 20201104_062721, 20201104_062751, 20201104_062819, 20201104_062918, 20201104_062944
06:37
  • New Preset
  • 20201104_070433, 20201104_070500, 20201104_070522, 20201104_070544, 20201104_070609
  • 20201104_073226, 20201104_073250, 20201104_073308, 20201104_073325, 20201104_073343
08:28
  • Too Cloudy, waiting.
08:50
  • Doing ESM, on account of the high clouds
  • 20201104_085413, 20201104_085441, 20201104_085635, 20201104_085703, 20201104_085722
  • Gain was really low
  • 20201104_092949, 20201104_093020, 20201104_093040, 20201104_093059, 20201104_093122
09:41
  • Re-doing preset: problem with ROBS machine
  • 20201104_094422, 20201104_094441, 20201104_094510, 20201104_094635, 20201104_094751, 20201104_094820
12:00
  • Heading to 08:23 +28
  • Failed on offset
13:05
  • Finished, along with the nation.

-- GregoryTaylor - 04 Nov 2020
Topic revision: r4 - 04 Nov 2020, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.