20201028 Closed Dome check of NCPA

17:27 All ready but OCAM is warm. Will test CL first
  • PresetAO
  • WfsArbitrator _83713|DEB| 222|2020-10-28 17:22:47.825234| MAIN > Loading setup file /home/AOeng/aoroot/calib/wfs/current/setups/LUCIFER_ACE-AO
  • LUCIFER NCPA LUT
    • 340 -19.67 -18.32 30.87 -5.21 6.71 -4.19 -9.87 -3.52
  • LUCIFER_applied_loop.jpg

17:47 Now authorized at RETROREF
  • PresetAO
  • WfsArbitrator _83713|DEB| 516|2020-10-28 17:46:40.692301| MAIN > Loading setup file /home/AOeng/aoroot/calib/wfs/current/setups/RETROREF_ACE-AO
  • RETROREF NCPA LUT
    • 340 -19.67 -18.32 30.87 -5.21 6.71 -4.19 -9.87 -3.52
  • Iincorrect again

18:00 back to LUCIFER

18:24 Loop Closed
  • Subwin
  • dark 3 frames, LUCI 156, 20201028_182538
  • three sets
    • check_20201028_on/check.log
    • check_20201028_15/check.log
    • check_20201028_off/check.log

  • ncpa_fit.jpg:
    ncpa_fit.jpg

  • sx_ncpa.jpg:
    sx_ncpa.jpg

21:05 Done. Turn over to mountian crew

TrackNo RefStar Mag bin #mod freq emGain gain mod nph/sa/fr Gopt AntiDrift SR SR (from slopes) FWHM [max,min] (mas) filter exp #frames
20201028_184640 360 10.0 1 501 1700 454 0.7 0.1 0.1 3 14.1 0.56 OFF 89.1 -1.0 [45, 42] clear H 5000 3
20201028_184830 330 10.1 1 501 1700 454 0.7 0.1 0.1 3 13.9 0.49 OFF 87.0 -1.0 [45, 43] clear H 5000 3
20201028_185012 300 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.1 0.53 OFF 78.7 -1.0 [51, 43] clear H 5000 3
20201028_185157 270 10.1 1 501 1700 454 0.7 0.1 0.1 3 13.9 0.55 OFF 85.8 -1.0 [47, 42] clear H 5000 3
20201028_185340 240 10.1 1 501 1700 454 0.7 0.1 0.1 3 13.9 0.56 OFF 92.8 -1.0 [43, 40] clear H 5000 3
20201028_185523 210 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.0 0.52 OFF 85.2 -1.0 [45, 42] clear H 5000 3
20201028_185704 180 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.0 0.54 OFF 63.3 -1.0 [62, 48] clear H 5000 3
20201028_190547 150 10.1 1 501 1700 454 0.7 0.1 0.1 3 13.9 0.59 OFF 89.2 -1.0 [45, 41] clear H 5000 3
20201028_191706 90 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.0 0.58 OFF 72.7 -1.0 [57, 43] clear H 5000 3
20201028_191846 60 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.1 0.58 OFF 86.6 -1.0 [47, 41] clear H 5000 3
20201028_192029 30 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.1 0.55 OFF 73.4 -1.0 [55, 44] clear H 5000 3
20201028_192213 0 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.0 0.56 OFF 85.1 -1.0 [48, 42] clear H 5000 3
  • psf_on.jpg:
    psf_on.jpg

TrackNo RefStar Mag bin #mod freq emGain gain mod nph/sa/fr Gopt AntiDrift SR SR (from slopes) FWHM [max,min] (mas) filter exp #frames
20201028_193116 180 10.0 1 501 1700 454 0.7 0.1 0.1 3 14.1 0.60 OFF 87.8 -1.0 [46, 41] clear H 5000 3
20201028_193254 165 10.0 1 501 1700 454 0.7 0.1 0.1 3 14.1 0.58 OFF 84.6 -1.0 [47, 43] clear H 5000 3
20201028_193432 150 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.0 0.59 OFF 88.1 -1.0 [46, 41] clear H 5000 3
20201028_193613 135 10.1 1 501 1700 454 0.7 0.1 0.1 3 13.9 0.58 OFF 86.9 -1.0 [46, 43] clear H 5000 3
20201028_193752 120 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.1 0.59 OFF 88.7 -1.0 [47, 42] clear H 5000 3
20201028_193934 105 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.0 0.60 OFF 87.7 -1.0 [46, 42] clear H 5000 3
  • psf_15.jpg:
    psf_15.jpg

TrackNo RefStar Mag bin #mod freq emGain gain mod nph/sa/fr Gopt AntiDrift SR SR (from slopes) FWHM [max,min] (mas) filter exp
20201028_194757 360 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.0 0.61 OFF 78.5 -1.0 [48, 45] clear H 5000
20201028_194945 330 10.1 1 501 1700 454 0.7 0.1 0.1 3 13.9 0.55 OFF 86.6 -1.0 [44, 43] clear H 5000
20201028_195127 300 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.0 0.56 OFF 87.2 -1.0 [45, 42] clear H 5000
20201028_195310 270 10.1 1 501 1700 454 0.7 0.1 0.1 3 13.9 0.58 OFF 87.2 -1.0 [45, 42] clear H 5000
20201028_195453 240 10.1 1 501 1700 454 0.7 0.1 0.1 3 13.9 0.59 OFF 78.0 -1.0 [46, 46] clear H 5000
20201028_195636 210 10.0 1 501 1700 454 0.7 0.1 0.1 3 14.1 0.55 OFF 65.4 -1.0 [54, 50] clear H 5000
20201028_195817 180 10.1 1 501 1700 454 0.7 0.1 0.1 3 14.1 0.56 OFF 61.1 -1.0 [60, 55] clear H 5000
20201028_195959 150 10.1 1 501 1700 454 0.7 0.1 0.1 3 13.8 0.58 OFF 43.4 -1.0 [79, 73] clear H 5000
  • psf_off.jpg:
    psf_off.jpg

-- DougMiller - 28 Oct 2020

I Attachment Action Size Date Who Comment
ncpa_fit.jpgjpg ncpa_fit.jpg manage 221 K 02 Nov 2020 - 06:45 DougMiller  
psf_15.jpgjpg psf_15.jpg manage 573 K 31 Oct 2020 - 05:57 DougMiller  
psf_off.jpgjpg psf_off.jpg manage 782 K 31 Oct 2020 - 05:57 DougMiller  
psf_on.jpgjpg psf_on.jpg manage 1 MB 31 Oct 2020 - 05:56 DougMiller  
sx_ncpa.jpgjpg sx_ncpa.jpg manage 135 K 02 Nov 2020 - 06:47 DougMiller  
Topic revision: r4 - 02 Nov 2020, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback