20201023 OSCO w/wo NCPA

01:02 WFS Ready, thanks Steve
  • About ready to collimate

01:05 OCSO script sent
  • LUCI 22-41
  • TN
    • 20201024_011120.log
    • 20201024_011437.log
  • LUCI 42-60
  • TN
    • 20201024_011901.log
    • 20201024_012208.log

01:23 OSCO Done
  • Warm OCAM
  • Power OFF WFS

02:02 IDL commands to put individual .fits files into a single .fits cube
  • NOTE: History is from bottom to top

ssh to obs* (for me this was dlmiller@obs4)
% cd /tmp
% idl
IDL>     cube = lonarr(2048,2048,10)
IDL>     for i=22,31 do begin& image=readfits("/Repository/20201024/luci1.20201024.00"+strtrim(string(i),2)+".fits")& cube[*,*,i-22]=image& end
IDL>     image_stack_cube, cube, bg32_41

IDL>     for i=32,41 do begin& image=readfits("/Repository/20201024/luci1.20201024.00"+strtrim(string(i),2)+".fits")& cube[*,*,i-32]=image& end
IDL>     image_stack_cube, cube, bg42_50

-> Note, the first offset postion of the second set has only 9 image because of the LUCI script includes
IDL>     cube = lonarr(2048,2048,9)
IDL>     for i=42,50 do begin& image=readfits("/Repository/20201024/luci1.20201024.00"+strtrim(string(i),2)+".fits")& cube[*,*,i-42]=image& end
IDL>     image_stack_cube, cube, bg42_50

IDL>     cube = lonarr(2048,2048,10)
IDL>     for i=51,60 do begin& image=readfits("/Repository/20201024/luci1.20201024.00"+strtrim(string(i),2)+".fits")& cube[*,*,i-51]=image& end
IDL>     image_stack_cube, cube, bg51_60

IDL> image22_31 = *bg32_41 - *bg22_31
IDL> image42_50 = *bg42_50 - *bg51_60
IDL> image32_41 = *bg32_41 - *bg22_31
IDL> image51_60 = *bg51_60 - *bg42_50

IDL> image22_31_final=image22_31
IDL> image22_31_final[where(image22_31 LT 0)] = 0
IDL> image32_41_final=image32_41
IDL> image32_41_final[where(image32_41 LT 0)] = 0
IDL> image42_50_final=image42_50
IDL> image42_50_final[where(image42_50 LT 0)] = 0
IDL> image51_60_final=image51_60
IDL> image51_60_final[where(image51_60 LT 0)] = 0

IDL> writefits, "luci22_31.fits", image22_31_final, head
IDL> writefits, "luci42_50.fits", image42_50_final, head
IDL> writefits, "luci32_41.fits", image32_41_final, head
IDL> writefits, "luci51_60.fits", image51_60_final, head

IDL>     check = readfits('luci51_60.fits')
   % READFITS: Now reading 2048 by 2048 by 10 array
IDL>     help, /recall_commands
IDL> quit

Copy each cube to the first TN set collected.

dlmiller@obs4:12 % scp luci22-31.fits AOeng@soul-sxwfs:/local/aomeas/adsec_data/20201024/Data_20201024_011120/luci.fits
   luci22-31.fits                                                                                             100%  160MB  80.0MB/s   00:02    
dlmiller@obs4:13 % scp luci32-41.fits AOeng@soul-sxwfs:/local/aomeas/adsec_data/20201024/Data_20201024_011437/luci.fits
   luci32-41.fits                                                                                             100%  160MB 160.0MB/s   00:01    
dlmiller@obs4:14 % scp luci42-50.fits AOeng@soul-sxwfs:/local/aomeas/adsec_data/20201024/Data_20201024_011902/luci.fits
   luci42-50.fits                                                                                             100%  144MB 144.0MB/s   00:01    
dlmiller@obs4:15 % scp luci51-60.fits AOeng@soul-sxwfs:/local/aomeas/adsec_data/20201024/Data_20201024_012208/luci.fits
   luci51-60.fits                                                                                             100%  160MB 160.0MB/s   00:01    

02:17 Process TNs via ELAB routines
% ssh AOeng@soul-sxwfs
% idl
IDL> ao_init
AO> a = getaoelab('20201024_011120')
AO> a->summary                      
AO> a->modalplot                     
AO> (a->residual_modes())->plotJitter
 
| Tracknum                       | 20201024_011120 |
| SR SE                          | 0.346186 |
| Tracknum                       | 20201024_011437 |
| SR SE                          | 0.453795 |
| Tracknum                       | 20201024_011902 |
| SR SE                          | 0.729200 |
| Tracknum                       | 20201024_012208 |
| SR SE                          | 0.690774 |

-- DougMiller - 24 Oct 2020
  • psf_011120.jpg:
    psf_011120.jpg

  • psf_011437.jpg:
    psf_011437.jpg

  • psf_011902.jpg:
    psf_011902.jpg

  • modal_011120.jpg:
    modal_011120.jpg

  • psf_012208.jpg:
    psf_012208.jpg

  • modal_011437.jpg:
    modal_011437.jpg

  • modal_011902.jpg:
    modal_011902.jpg

  • modal_012208.jpg:
    modal_012208.jpg

  • jitter_011120.jpg:
    jitter_011120.jpg

  • jitter_011437.jpg:
    jitter_011437.jpg

  • jitter_011902.jpg:
    jitter_011902.jpg

  • jitter_012208.jpg:
    jitter_012208.jpg

  • jitter_011437.jpg:
    jitter_011437.jpg

  • modal_011437.jpg:
    modal_011437.jpg
I Attachment Action Size Date Who Comment
jitter_011120.jpgjpg jitter_011120.jpg manage 70 K 24 Oct 2020 - 05:24 DougMiller  
jitter_011437.jpgjpg jitter_011437.jpg manage 64 K 24 Oct 2020 - 05:28 DougMiller  
jitter_011902.jpgjpg jitter_011902.jpg manage 90 K 24 Oct 2020 - 05:25 DougMiller  
jitter_012208.jpgjpg jitter_012208.jpg manage 85 K 24 Oct 2020 - 05:25 DougMiller  
modal_011120.jpgjpg modal_011120.jpg manage 61 K 24 Oct 2020 - 05:23 DougMiller  
modal_011437.jpgjpg modal_011437.jpg manage 62 K 24 Oct 2020 - 05:30 DougMiller  
modal_011902.jpgjpg modal_011902.jpg manage 59 K 24 Oct 2020 - 05:24 DougMiller  
modal_012208.jpgjpg modal_012208.jpg manage 61 K 24 Oct 2020 - 05:24 DougMiller  
psf_011120.jpgjpg psf_011120.jpg manage 76 K 24 Oct 2020 - 05:22 DougMiller  
psf_011437.jpgjpg psf_011437.jpg manage 74 K 24 Oct 2020 - 05:22 DougMiller  
psf_011902.jpgjpg psf_011902.jpg manage 78 K 24 Oct 2020 - 05:22 DougMiller  
psf_012208.jpgjpg psf_012208.jpg manage 68 K 24 Oct 2020 - 05:23 DougMiller  
Topic revision: r2 - 24 Oct 2020, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback