20201003 LBTB Science

OSCO

01:30 Center Pupil stuck
  • All WFS processes disconnect from the msgdmrtdb
  • w_stop_all
  • w_start_all
  • OK send OSCO again

w_check

msgdrtdb             running
mirrorctrl           running but NOT connected to Msgd
pinger               running but NOT connected to Msgd
powerboard           running but NOT connected to Msgd
slopecompctrl        running but NOT connected to Msgd
techviewctrl         running but NOT connected to Msgd
ocam2                running but NOT connected to Msgd
ccd47                running but NOT connected to Msgd
ttctrl               running but NOT connected to Msgd
adc1                 running but NOT connected to Msgd
adc2                 running but NOT connected to Msgd
rerotator            running but NOT connected to Msgd
filterwheel1         running but NOT connected to Msgd
filterwheel2         running but NOT connected to Msgd
mercury              running but NOT connected to Msgd
cubestage            running but NOT connected to Msgd
baysidex             running but NOT connected to Msgd
baysidey             running but NOT connected to Msgd
baysidez             running but NOT connected to Msgd
cameralensctrl       running but NOT connected to Msgd
picctrl              running but NOT connected to Msgd
optloopdiag          NOT running
pupilcheckocam2      running but NOT connected to Msgd
masterdiagnostic     running but NOT connected to Msgd
housekeeperWFS       running but NOT connected to Msgd
dbfiller             running but NOT connected to Msgd
wfsarb               running but NOT connected to Msgd
od_gopt              running but NOT connected to Msgd
gopt                 running but NOT connected to Msgd

01:45 RunAO
  • GOPT failed
  • could not get IIF to see the loop was still closed
  • Had in AUTO mode
  • Set to Intervention mode for science target next

02:04 Closed loop successfull
  • did not turn on GOPT. Ratio was 0.06. Too low, I think, and gopt would not be stable. Need 0.15 or larger.
  • preset 14.5
  • wfs 15.7
  • Info entered in spreadsheet
  • 1.1" DIMM
  • TN
    • 022518 (loop paused)
    • 022605
    • 022711

02:30 CLosed Loop successfull
  • Optimize gain failed on second pass of HO2
  • Set gains from plots, 9.0, 3.15, 3.0

02:40 Loop Open
  • Dave paused script
  • reclose and set gains to 6.05, 2.5, 2.46
  • Dave resume script

02:46 Coils disabled from fastdiagnositics
AdSecArbitrator_137315|INF|      1109|2020-10-03 02:46:22.300513|  COMMANDHANDLER > FSM (status: AORunning) has received command 2029 (TTOffload)
AdSecArbitrator_137315|INF|      1110|2020-10-03 02:46:22.304351|  COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
AdSecArbitrator_137315|ERR|      1111|2020-10-03 02:46:26.329578|    ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_137315|ERR|      1112|2020-10-03 02:46:26.329631|    ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
20200310 02:46:26.3305 Alert: Error: COILS DISABLED
AdSecArbitrator_137315|WAR|      1113|2020-10-03 02:46:26.330372|            MAIN > Cannot dispatch alert: TcpTransceiver.cpp:284: Ice::ConnectionLostException:
AdSecArbitrator_137315|WAR|      1113|2020-10-03 02:46:26.330372|            MAIN >  . connection lost: recv() returned zero
AdSecArbitrator_137315|INF|      1114|2020-10-03 02:46:26.392088|    ALERTHANDLER > Received from masterdiagnostic.L a D
  • IDL print, fsm_power_off()
  • power on
  • load program
  • setflatao
  • stop/start wfs arb
  • LUCI send preset

02:58 timeout center pupil, bin 3
 Split offset (pixels): x=0, y=1
python_110076      |INF|      7730|2020-10-03 02:58:12.263583|             MAIN > Reading 1127 frames
python_110076      |INF|      7731|2020-10-03 02:58:18.465277|             MAIN > Starting calculation
python_110076      |INF|      7732|2020-10-03 02:58:18.522745|             MAIN > findPupils() elapsed time: 0.013 seconds
python_110076      |INF|      7733|2020-10-03 02:58:18.522868|             MAIN > findPupils() data: [ 28.142 -  26.523 -  43.754 -   0.000,  28.142 -  42.523 -  43.754 -   0.000,  28.142 -  26.523 -  27.754 -   0.000,  28.142 -  42.523 -  27.754 -   0.000]
python_110076      |INF|      7734|2020-10-03 02:58:18.522927|             MAIN > CENTERS: 26.5 43.8 42.5 43.8 26.5 27.8 42.5 27.8
python_110076      |INF|      7735|2020-10-03 02:58:18.522977|             MAIN > PupDiam Theorical: 13.3
python_110076      |INF|      7736|2020-10-03 02:58:18.523007|             MAIN > PupDiam Computed:  28.1
python_110076      |INF|      7737|2020-10-03 02:58:18.523042|             MAIN > Skipping step because of bad pupil diameter (PupDiam) estimation: error is 14.84, threshold is  2.00
python_110076      |INF|      7738|2020-10-03 02:58:18.524831|             MAIN > Threshold: 0.4 Split: 1  Exptime: 6.2  Delay: 0.1
python_110076      |INF|      7739|2020-10-03 02:58:18.524878|             MAIN > Method: sum
python_110076      |INF|      7740|2020-10-03 02:58:18.524931|             MAIN > Pupil interdistance (pixels): x=16, y=16
python_110076      |INF|      7741|2020-10-03 02:58:18.524977|             MAIN > Split offset (pixels)

03:16 Skip Frame
AdSecArbitrator_144619|INF|       438|2020-10-03 03:22:12.123603|  COMMANDHANDLER > FSM (status: AORunning) has received command 2029 (TTOffload)
AdSecArbitrator_144619|INF|       439|2020-10-03 03:22:12.129241|  COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
AdSecArbitrator_144619|WAR|       440|2020-10-03 03:22:19.897566|            MAIN > Skip frame detected!
AdSecArbitrator_144619|INF|       442|2020-10-03 03:22:21.003297|            MAIN > Received cmd: StopAo(1)
idl_130201         |INF|      1929|2020-10-03 03:22:21.003775|             MAIN > fsm_stop_ao start
idl_130201         |INF|      1930|2020-10-03 03:22:21.003860|             MAIN > fsm_skip_recovery FORCE set
AdSecArbitrator_144619|INF|       443|2020-10-03 03:22:21.003359|  COMMANDHANDLER > FSM (status: AORunning) has received command 2015 (Stop Ao)
AdSecArbitrator_144619|INF|       444|2020-10-03 03:22:21.003392|   SERIALIZATION > StopAoImpl(): restoreShape = 1
  • tried to reclose loop but safeskip immediately with lngains

03:34 Timeout on center pupil. camera lens corrections not applied because of pupil spacing error. Bin 2
python_179259      |INF|       104|2020-10-03 03:34:59.374183|             MAIN > Reading 500 frames
python_179259      |INF|       105|2020-10-03 03:35:04.371375|             MAIN > Starting calculation
python_179259      |INF|       106|2020-10-03 03:35:04.424813|             MAIN > findPupils() elapsed time: 0.019 seconds
python_179259      |INF|       107|2020-10-03 03:35:04.424938|             MAIN > findPupils() data: [ 49.366 -  36.404 -  63.444 -   0.000,  49.366 -  60.404 -  63.444 -   0.000,  49.366 -  36.404 -  39.444 -   0.000,  49.366 -  60.404 -  39.444 -   0.000]
python_179259      |INF|       108|2020-10-03 03:35:04.424995|             MAIN > CENTERS: 36.4 63.4 60.4 63.4 36.4 39.4 60.4 39.4
python_179259      |INF|       109|2020-10-03 03:35:04.425045|             MAIN > PupDiam Theorical: 20.0
python_179259      |INF|       110|2020-10-03 03:35:04.425074|             MAIN > PupDiam Computed:  49.4
python_179259      |INF|       111|2020-10-03 03:35:04.425111|             MAIN > Skipping step because of bad pupil diameter (PupDiam) estimation: error is 29.37, threshold is  3.00
python_179259      |INF|       112|2020-10-03 03:35:04.426897|             MAIN > Threshold: 0.4 Split: 1  Exptime: 5.0  Delay: 0.1
python_179259      |INF|       113|2020-10-03 03:35:04.426939|             MAIN > Method: sum
python_179259      |INF|       114|2020-10-03 03:35:04.426967|             MAIN > Pupil interdistance (pixels): x=24, y=24
python_179259      |INF|       115|2020-10-03 03:35:04.426995|             MAIN > Split offset (pixels): x=0, 

03:40 Error on Center Pupil
WfsArbitrator_165753|INF|       196|2020-10-03 03:40:57.857353|             MAIN > Setting tiptilt to amp= 3.00, freq=761.00, offx= 0.00, offy= 0.00
WfsArbitrator_165753|INF|       197|2020-10-03 03:40:57.859509|             MAIN > calibHODarkInternal(): starting measure, 100 frames
WfsArbitrator_165753|INF|       198|2020-10-03 03:41:10.009022|             MAIN > ccd.equalize_quadrants(): nothing to do for ocam2
WfsArbitrator_165753|ERR|       199|2020-10-03 03:41:14.128852|             MAIN > Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
WfsArbitrator_165753|DEB|       200|2020-10-03 03:41:14.129261|             MAIN > arbFunc updateModulationInternal (, 'FLAOWFS', 'LUCIFER', 761)
WfsArbitrator_165753|INF|       201|2020-10-03 03:41:14.129609|             MAIN > Tip-tilt frequency is not synced, skipping update
WfsArbitrator_165753|DEB|       202|2020-10-03 03:41:14.129672|             MAIN > arbFunc updateModulationInternal done.

03:45 w_stop_all, w_start_all
  • wfshousekeeper fail
  • w_stop_all, w_start_all
  • send preset
  • didnt press check flux. stayed bin 2, should have been bin 3
  • Cancel preset
  • send preset again
  • bin 3 oK

04:00 Loops closed. LUCI taking data
  • bin 3
  • TN 041227, 041817, 042054, 042221

04:27 Preset, closed loop ok
  • bin 3
  • gains 3.690, 157, 0.78
  • TN 043357, 043525, 043648, 043813
  • 1.09" DIMM

04:54 Almost done with script
  • TN with GOPT off 045456
  • turn on AUX LOOPS
  • AUX LOOP GUI
  • GOPT 0.16
  • TN with GOPT 045711, 045737, 045758

05:05 Preset bin 3
  • gain 5.4, 3.6, 3.6
  • no GOPT. would have been 0.08
  • TN 051431, 052221

05:40 Binocular SL LUCI