OSCO

02:03 OSCO Preset
  • loop closed
  • optical gain = 0.39
  • 020927
  • bayside stage not move. 02:11:37

TCS

Tue Sep 8 02:10:59.456 2020 aos.info - HO offload command end
Tue Sep 8 02:13:03.703 2020 aos.OffsetXY{FLAO}.failed - OffsetXY{FLAO}[1141] - [AOException] RETRY: Stages position not reached (-5001) TIMEOUT_ERROR
Tue Sep 8 02:25:41.431 2020 aos.Resume{FLAO}.started - Resume{FLAO}[1131] 
Tue Sep 8 02:25:41.605 2020 aos.Resume{FLAO}.failed - Resume{FLAO}[1131] - [AOException] RETRY: Star not found - loop still paused (-20002) WFSARB_STAR_WRONGFLUX
Tue Sep 8 02:25:43.853 2020 aos.StartAO{FLAO}.started - StartAO{FLAO}[1143] 

Bayside stages

Y Stage
CopleyCtrl_166905  |INF|       190|2020-09-08 01:49:55.063412|             MAIN > Moving to: -50.290 mm
CopleyCtrl_166905  |INF|       191|2020-09-08 01:49:56.094673|             MAIN > Stage pos (mm): -50.295, current (A): 0.430
CopleyCtrl_166905  |INF|       192|2020-09-08 02:02:38.079328|             MAIN > Moving to: -47.210 mm
CopleyCtrl_166905  |INF|       193|2020-09-08 02:02:38.737411|             MAIN > Stage pos (mm): -50.284, current (A): -0.320
CopleyCtrl_166905  |INF|       194|2020-09-08 02:02:38.973523|             MAIN > Stage pos (mm): -49.661, current (A): -0.180
CopleyCtrl_166905  |INF|       195|2020-09-08 02:02:39.207981|             MAIN > Stage pos (mm): -49.083, current (A): -0.290
CopleyCtrl_166905  |INF|       196|2020-09-08 02:02:39.442275|             MAIN > Stage pos (mm): -48.397, current (A): -0.350
CopleyCtrl_166905  |INF|       197|2020-09-08 02:02:39.676619|             MAIN > Stage pos (mm): -47.736, current (A): -0.150
CopleyCtrl_166905  |INF|       198|2020-09-08 02:02:39.909080|             MAIN > Stage pos (mm): -47.253, current (A): -0.110
CopleyCtrl_166905  |INF|       199|2020-09-08 02:02:40.135630|             MAIN > Stage pos (mm): -47.228, current (A): -0.040
CopleyCtrl_166905  |INF|       200|2020-09-08 02:02:40.370015|             MAIN > Stage pos (mm): -47.222, current (A): -0.030
CopleyCtrl_166905  |INF|       201|2020-09-08 02:02:40.604383|             MAIN > Stage pos (mm): -47.214, current (A): -0.040
CopleyCtrl_166905  |INF|       202|2020-09-08 02:04:23.857940|             MAIN > Moving to: -47.446 mm
CopleyCtrl_166905  |INF|       203|2020-09-08 02:04:24.549310|             MAIN > Stage pos (mm): -47.410, current (A): 0.040

X Stage

Move to Center Star
CopleyCtrl_166891  |INF|       153|2020-09-08 02:04:21.717223|             MAIN > Moving to: -73.771 mm
CopleyCtrl_166891  |INF|       154|2020-09-08 02:04:22.889088|             MAIN > Stage pos (mm): -73.721, current (A): -0.360
CopleyCtrl_166891  |INF|       155|2020-09-08 02:04:23.123415|             MAIN > Stage pos (mm): -73.733, current (A): -0.440
CopleyCtrl_166891  |INF|       156|2020-09-08 02:04:23.328540|             MAIN > Stage pos (mm): -73.753, current (A): -0.450
CopleyCtrl_166891  |INF|       157|2020-09-08 02:04:23.523827|             MAIN > Stage pos (mm): -73.766, current (A): -0.450
CopleyCtrl_166891  |INF|       158|2020-09-08 02:04:23.719164|             MAIN > Stage pos (mm): -73.769, current (A): -0.460

Telescope offset (failed, first try)
CopleyCtrl_166891  |INF|       159|2020-09-08 02:10:57.635659|             MAIN > Moving to: -73.739 mm
CopleyCtrl_166891  |INF|       160|2020-09-08 02:10:58.207809|             MAIN > Stage pos (mm): -73.779, current (A): 0.000
CopleyCtrl_166891  |INF|       161|2020-09-08 02:10:58.432473|             MAIN > Stage pos (mm): -73.779, current (A): 0.420
CopleyCtrl_166891  |INF|       162|2020-09-08 02:10:58.658954|             MAIN > Stage pos (mm): -73.779, current (A): 0.520
CopleyCtrl_166891  |INF|       163|2020-09-08 02:10:58.893388|             MAIN > Stage pos (mm): -73.779, current (A): 0.650
CopleyCtrl_166891  |INF|       164|2020-09-08 02:10:59.127713|             MAIN > Stage pos (mm): -73.779, current (A): 0.790
CopleyCtrl_166891  |INF|       165|2020-09-08 02:10:59.362263|             MAIN > Stage pos (mm): -73.779, current (A): 0.900
CopleyCtrl_166891  |INF|       166|2020-09-08 02:10:59.596412|             MAIN > Stage pos (mm): -73.779, current (A): 1.040
CopleyCtrl_166891  |INF|       167|2020-09-08 02:10:59.830852|             MAIN > Stage pos (mm): -73.779, current (A): 1.150
CopleyCtrl_166891  |INF|       168|2020-09-08 02:11:00.065303|             MAIN > Stage pos (mm): -73.779, current (A): 1.300
CopleyCtrl_166891  |INF|       169|2020-09-08 02:11:00.299680|             MAIN > Stage pos (mm): -73.779, current (A): 1.420

(failed, second try)
CopleyCtrl_166891  |INF|       170|2020-09-08 02:11:40.731038|             MAIN > Moving to: -73.739 mm
CopleyCtrl_166891  |INF|       171|2020-09-08 02:11:41.119770|             MAIN > Stage pos (mm): -73.781, current (A): -0.010
CopleyCtrl_166891  |INF|       172|2020-09-08 02:11:41.354140|             MAIN > Stage pos (mm): -73.781, current (A): 0.320
CopleyCtrl_166891  |INF|       173|2020-09-08 02:11:41.588534|             MAIN > Stage pos (mm): -73.781, current (A): 0.460
CopleyCtrl_166891  |INF|       174|2020-09-08 02:11:41.822860|             MAIN > Stage pos (mm): -73.781, current (A): 0.580
CopleyCtrl_166891  |INF|       175|2020-09-08 02:11:42.057237|             MAIN > Stage pos (mm): -73.781, current (A): 0.730
CopleyCtrl_166891  |INF|       176|2020-09-08 02:11:42.291604|             MAIN > Stage pos (mm): -73.781, current (A): 0.850
CopleyCtrl_166891  |INF|       177|2020-09-08 02:11:42.526037|             MAIN > Stage pos (mm): -73.781, current (A): 1.000
CopleyCtrl_166891  |INF|       178|2020-09-08 02:11:42.760427|             MAIN > Stage pos (mm): -73.782, current (A): 1.130
CopleyCtrl_166891  |INF|       179|2020-09-08 02:11:42.994744|             MAIN > Stage pos (mm): -73.782, current (A): 1.260
CopleyCtrl_166891  |INF|       180|2020-09-08 02:11:43.229169|             MAIN > Stage pos (mm): -73.782, current (A): 1.400
CopleyCtrl_166891  |INF|       181|2020-09-08 02:11:43.463469|             MAIN > Stage pos (mm): -73.782, current (A): 1.530
CopleyCtrl_166891  |INF|       182|2020-09-08 02:11:43.697879|             MAIN > Stage pos (mm): -73.782, current (A): 1.670
CopleyCtrl_166891  |INF|       183|2020-09-08 02:11:43.932301|             MAIN > Stage pos (mm): -73.782, current (A): 1.810

(failed, third try)
CopleyCtrl_166891  |INF|       184|2020-09-08 02:12:23.834429|             MAIN > Moving to: -73.739 mm
CopleyCtrl_166891  |INF|       185|2020-09-08 02:12:24.752455|             MAIN > Stage pos (mm): -73.792, current (A): -0.010
CopleyCtrl_166891  |INF|       186|2020-09-08 02:12:24.986776|             MAIN > Stage pos (mm): -73.793, current (A): 0.790
CopleyCtrl_166891  |INF|       187|2020-09-08 02:12:25.221137|             MAIN > Stage pos (mm): -73.793, current (A): 0.950
CopleyCtrl_166891  |INF|       188|2020-09-08 02:12:25.455548|             MAIN > Stage pos (mm): -73.793, current (A): 1.140
CopleyCtrl_166891  |INF|       189|2020-09-08 02:12:25.689888|             MAIN > Stage pos (mm): -73.793, current (A): 1.300
CopleyCtrl_166891  |INF|       190|2020-09-08 02:12:25.924230|             MAIN > Stage pos (mm): -73.793, current (A): 1.460
CopleyCtrl_166891  |INF|       191|2020-09-08 02:12:26.158608|             MAIN > Stage pos (mm): -73.793, current (A): 1.640
CopleyCtrl_166891  |INF|       192|2020-09-08 02:12:26.393009|             MAIN > Stage pos (mm): -73.793, current (A): 1.800
CopleyCtrl_166891  |INF|       193|2020-09-08 02:12:26.627407|             MAIN > Stage pos (mm): -73.793, current (A): 1.980

After AO offset failed, I manually requested -78, succefull

CopleyCtrl_166891  |INF|       194|2020-09-08 02:14:08.035267|             MAIN > Moving to: -78.800 mm
CopleyCtrl_166891  |INF|       195|2020-09-08 02:14:08.998124|             MAIN > Stage pos (mm): -73.803, current (A): -0.010
CopleyCtrl_166891  |INF|       196|2020-09-08 02:14:09.222797|             MAIN > Stage pos (mm): -76.267, current (A): 0.220
CopleyCtrl_166891  |INF|       197|2020-09-08 02:14:09.449331|             MAIN > Stage pos (mm): -77.314, current (A): 0.370
CopleyCtrl_166891  |INF|       198|2020-09-08 02:14:09.673893|             MAIN > Stage pos (mm): -78.405, current (A): 0.590
CopleyCtrl_166891  |INF|       199|2020-09-08 02:14:09.908349|             MAIN > Stage pos (mm): -78.830, current (A): 0.580
CopleyCtrl_166891  |INF|       200|2020-09-08 02:14:10.142654|             MAIN > Stage pos (mm): -78.831, current (A): 0.680
CopleyCtrl_166891  |INF|       201|2020-09-08 02:14:10.376981|             MAIN > Stage pos (mm): -78.831, current (A): 0.790
CopleyCtrl_166891  |INF|       202|2020-09-08 02:14:10.611389|             MAIN > Stage pos (mm): -78.831, current (A): 0.880
CopleyCtrl_166891  |INF|       203|2020-09-08 02:14:10.845789|             MAIN > Stage pos (mm): -78.831, current (A): 0.990
CopleyCtrl_166891  |INF|       204|2020-09-08 02:14:11.080172|             MAIN > Stage pos (mm): -78.831, current (A): 1.070
CopleyCtrl_166891  |INF|       205|2020-09-08 02:14:11.314507|             MAIN > Stage pos (mm): -78.831, current (A): 1.180
CopleyCtrl_166891  |INF|       206|2020-09-08 02:14:11.548878|             MAIN > Stage pos (mm): -78.831, current (A): 1.240
CopleyCtrl_166891  |INF|       207|2020-09-08 02:14:11.783258|             MAIN > Stage pos (mm): -78.830, current (A): 1.360
CopleyCtrl_166891  |INF|       208|2020-09-08 02:14:12.017703|             MAIN > Stage pos (mm): -78.830, current (A): 1.460
CopleyCtrl_166891  |INF|       209|2020-09-08 02:14:12.252020|             MAIN > Stage pos (mm): -78.830, current (A): 1.520
CopleyCtrl_166891  |INF|       210|2020-09-08 02:14:12.486336|             MAIN > Stage pos (mm): -78.830, current (A): 1.640
CopleyCtrl_166891  |INF|       211|2020-09-08 02:14:12.720706|             MAIN > Stage pos (mm): -78.829, current (A): 1.740
CopleyCtrl_166891  |INF|       212|2020-09-08 02:14:12.935669|             MAIN > Stage pos (mm): -78.827, current (A): 1.810
CopleyCtrl_166891  |INF|       213|2020-09-08 02:14:13.130879|             MAIN > Stage pos (mm): -78.824, current (A): 1.850
CopleyCtrl_166891  |INF|       214|2020-09-08 02:14:13.326223|             MAIN > Stage pos (mm): -78.821, current (A): 1.900
CopleyCtrl_166891  |INF|       215|2020-09-08 02:14:13.533326|             MAIN > Stage pos (mm): -78.815, current (A): 1.930

-- DougMiller - 08 Sep 2020