SX NCPA, or bust!

Power bump at 20:44, just when we finally got started. Need to restart everything.

21:14 Ready!

NCPA:

Disturb: 20200830_032553
Angle Z4 Z5 Z6 Z7 Z8 Z9 Z10 Z11
0 -20 -20 20 -5 10 10 -10 -2.7
30 -16.4 10 -10 -10 0 10 10 -2.6
60 -9.2 -10 0 -10 0 -5 0 -3.6
90 0 -20 -10 -5 -5 -10 -10 -5.7
120 8.5 -20 -40.9 0 0 10 -15 -8.1
150 14.4 40 -50 5 -5 10 10 -10.2
180 15.5 60 0 5 0 -5 10 -11.6
210 12 30 40 10 5 -20 -10 -12
240 4.7 -30 35 5 10 0 -15 -10.6
270 -4.4 -20 0 0 10 10 0 -8.6
300 -13 10 10 0 10 -5 10 -6.2
330 -18.7 -10 30 -5 5 -10 -5 -4.1
Duplicate TN at 330, 2 X 300, vibrations, 60, Turned NCPA off, on accident

subwin SW 1 955 840 256 256

Dark: 20200831_213322

Start: 20200831_213736

End: 20200831_225148

AO> ao=obj_new('aodataset',from='starting TN',to='ending TN')

AO> log_twiki, ao

I cut off some columns and added Rotator Angle by hand.
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq emGain gain mod nph/sa/fr Gopt AntiDrift SR Rotator Angle
20200831_213736 ??? 10.6 90 5 NaN -1.00 161000 1 501 1700 600 0.5 0.1 0.1 3 8.1 0.52 OFF 90.3 360
20200831_214231 ??? 10.7 90 5 NaN -1.00 161000 1 501 1700 600 0.5 0.1 0.1 3 8.0 0.49 OFF 41.4 330
20200831_214516 ??? 10.5 90 5 NaN -1.00 161000 1 501 1700 600 0.4 0.1 0.1 3 9.0 0.50 OFF 80.8 330
20200831_215120 ??? 10.6 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 8.6 0.57 OFF 57.9 300
20200831_215205 ??? 10.6 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 8.6 0.54 OFF 60.2 300
20200831_215252 ??? 10.6 90 5 NaN -1.00 161000 1 501 1700 600 0.7 0.1 0.1 3 8.6 0.57 OFF 66.3 300
20200831_215932 ??? 10.7 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 7.9 0.60 OFF 85.7 270
20200831_220847 ??? 10.7 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 8.1 0.57 OFF 86.8 240
20200831_221536 ??? 10.6 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 8.5 0.60 OFF 79.0 210
20200831_222117 ??? 10.6 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 8.4 0.63 OFF 89.1 180
20200831_222802 ??? 10.7 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 8.0 0.59 OFF 89.4 150
20200831_223341 ??? 10.7 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 7.9 0.57 OFF 86.1 120
20200831_224030 ??? 10.6 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 8.4 0.61 OFF 86.7 90
20200831_224556 ??? 10.7 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 7.8 0.63 OFF 75.2 60
20200831_224709 ??? 10.6 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 8.4 0.60 OFF 93.0 60
20200831_225148 ??? 10.7 90 5 NaN -1.00 161000 1 501 1700 600 0.6 0.1 0.1 3 8.0 0.60 OFF 83.4 30
-- GregoryTaylor - 31 Aug 2020
Topic revision: r3 - 14 Sep 2020, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback