20200608 SX Flat with New 4D

Setup

11:30 MST RR Installed, lights off, laser on

12:00 See fringes on 4D

12:20 Forgot to start AdSec in correct version
  • cd ~/4D/
  • source the env
  • Stop, Start
  • $ InterferometerCtrl -i interferometerctrl
  • idl
  • > @startup-onlycom
  • > print, idl_4d_init()
  • a=get_img4d(/show)
    • IDL> help, a
    • FLOAT = Array[890, 890]
  • Ready to correct hexapod

12:29 Align hexapod with old reconstructor (/local/aomeas/adsec_calib/hexapod/20191122_203009/)
  • print, hexalign()
    • 0.48103825 -0.72540232 0.010099652 75.510747 47.228068 -0.0000000
  • print, hexalign(/apply)
    • new Hex position: -0.247, 2.55 -1.019 -34.62 4.17
  • print, hexalign(/apply)
  • did not correct coma.
  • Maybe the old reconstructor is not correct (orientaion should be the same)

12:45 Collect new Hexapod reconstructor
  • print, hexapod_opt_calib()
  • Froze part way through data collection
reading file/local/aomeas/adsec_calib/4d/img4d/9.4D
Waiting for iteration n       0
       3 +1
Hexapod in position after 008 seconds.
Acquiring RAW frames from 4D interferometer
img4d
img4d
4D Capturing and Processing completed
reading file/local/aomeas/adsec_calib/4d/img4d/0.4D

^C^C^C^C

2:31 collect data to flatten
  • AdOpt>print, i4d_opt_intmat(0,40,AMPRMS=250e-9)
  • 20200608_213041
[AOeng@sxadsec adsec_utilities]$ scp AOeng#dxadsec:~/aoroot/idl/adsec_lib/adsec_utilities/if_redux_new.pro . [AOeng@sxadsec adsec_utilities]$ scp AOeng@dxadsec:~/aoroot/idl/adsec_lib/adsec_utilities/tools_planefit.pro . Edits to if_redux_new.pro to read files from correct directory and with ..4D ending IDL> .compile ~/4D/aoroot/idl/adsec_lib/adsec_utilities/tools_planefit.pro IDL> .compile ~/4D/aoroot/idl/adsec_lib/adsec_utilities/if_redux_new.pro

  • IDL> print, if_redux_new(/MODAL, '20200608_213041', plot=4, /force)
    • should do plot=3 or 2 or 1??
  • IDL> print, build_int_mat(['20200608_213041'])
  • AdOpt>print, opt_int_mat_reduce2(40, track='20200608_213041')
    • /local/aomeas/adsec_calib/flat/20200608_221223/flattening_result.sav
    • from ~300 wv with 8 modes removed to ~290 wv

  • AdOpt>print, i4d_opt_intmat(41,100,AMPRMS=250e-9)
    • 20200608_221635
  • IDL> print, idl_4d_produce('20200608_221635')
  • Looks like we are not finding the trigger frame properly
  • Try with 0-20 modes agian

  • AdOpt>print, i4d_opt_intmat(0,20,AMPRMS=250e-9)

  • Fixed if_redux_new. Used flist[], changed to files[]
  • IDL> print, if_redux_new(/MODAL, '20200608_221635', plot=4, /force)
  • IDL> print, if_redux_new(/MODAL, '20200608_213041', plot=4, /force)
  • IDL> print, build_int_mat(['20200608_213041','20200608_221635'])
    • original_flat.jpg
    • 297 wv
  • IDL> print, opt_int_mat_reduce2(100, track='20200608_213041')
    • /local/aomeas/adsec_calib/flat/20200608_231856/flattening_result.sav
    • 100_modes.jpg
    • 116 wv
  • IDL> print, opt_int_mat_reduce2(100, track='20200608_213041')
    • /local/aomeas/adsec_calib/flat/20200608_232247/flattening_result.sav

  • AdOpt>print, i4d_opt_intmat(101,200)
    • 20200608_232737
  • AdOpt>print, i4d_opt_intmat(201,300)
    • 20200608_232831
  • AdOpt>print, i4d_opt_intmat(301,400)
    • 20200608_232930
  • AdOpt>print, i4d_opt_intmat(401,500)
    • 20200608_233013
  • AdOpt>print, i4d_opt_intmat(501,600)
    • 20200608_233109

  • IDL> print, idl_4d_produce('20200608_232737')
  • IDL> print, if_redux_new(/MODAL, '20200608_232737', plot=1, /force)
  • IDL> print, build_int_mat(['20200608_213041','20200608_221635','20200608_232737'])
  • AdOpt>print, opt_int_mat_reduce2(200, track='20200608_213041')
    • /local/aomeas/adsec_calib/flat/20200608_234531/flattening_result.sav
    • 200_modes_1st.jpg
    • 102 wv
    • /local/aomeas/adsec_calib/flat/20200608_234827/flattening_result.sav
    • 200_modes_2nd.jpg
    • 108 wv

4:56 Collect IF data
  • i4d_collect
    • /home/aoeng/4D/aoroot/idl/adsec_lib/adsec/level3
  • starts at 20200608_235145
  • end at 20200609_002046

-- DougMiller - 08 Jun 2020