20200207_DX_Night]] SX AO of Satelites with IRTC

Check best exposure time for IRTC

Darks

  • exp 0.5 s
  • TN 073859
  • irtc 02, 073840

  • exp 0.2 s
  • TN 074026
  • irtc 3, 073939

  • exp 0.1 s
  • TN 074124
  • irtc 4, 074121

Exposure Data

  • exp 0.5 s
  • TN 074430
  • irtc 5, 074425

  • exp 0.2 s
  • TN 074553
  • irtc 6, 074552

  • exp 0.1 s
  • TN 074640
  • irtc 7, 074638

  • Choose exp = 0.5 ses

Check focus position WUnit bayside stages for IRTC

  • exp = 0.5 sec

  • 085830
  • 47.75
  • 8, 085825

  • 085936
  • 47.55
  • 9, 085934

  • 090015
  • 47.35
  • 10 090016

  • 090046
  • 47.15
  • 11 090047

  • 090121
  • 47.75
  • 12, 090124

  • 090156
  • 47.95
  • 13, 090159

  • 090226
  • 48.15
  • 14, 090229, 15, 090252

  • 090321
  • 48.35
  • 16, 0903210

  • Dark exp = 0.1 s
  • 17, 090506

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq emGain gain mod nph/sa/fr Gopt AntiDrift SR SR (from slopes) FWHM (mas) filter exp #frames disturb SN skip notes
20200207_085830 ??? 9.9 190091 13 1.18 0.10 161000 1 503 1700 382 5.6 0.6 5.6 3 16.8 1.00 OFF 65.3 -100.0 -1 H 100 1 ONSKY NO 0  
20200207_085936 ??? 9.8 189825 13 1.05 0.10 161000 1 503 1700 382 5.6 0.6 5.6 3 17.2 1.00 OFF 67.1 -100.0 -1 H 100 1 ONSKY NO 0  
20200207_090015 ??? 9.9 189663 12 1.07 0.10 161000 1 503 1700 382 5.6 0.6 5.6 3 16.5 1.00 OFF 45.9 -100.0 -1 H 100 1 ONSKY NO 0  
20200207_090046 ??? 9.9 189535 13 1.14 0.10 161000 1 503 1700 382 5.6 0.6 5.6 3 16.0 1.00 OFF 42.2 -100.0 -1 H 100 1 ONSKY NO 0  
20200207_090121 ??? 9.9 189387 12 1.43 0.10 161000 1 503 1700 382 5.6 0.6 5.6 3 16.5 1.00 OFF 32.9 -100.0 -1 H 100 1 ONSKY NO 0  
20200207_090156 ??? 9.9 189237 14 1.49 0.10 161000 1 503 1700 382 5.6 0.6 5.6 3 16.4 1.00 OFF 63.6 -100.0 -1 H 100 1 ONSKY NO 0  
20200207_090226 ??? 9.9 189108 14 1.22 0.10 161000 1 503 1700 382 5.6 0.6 5.6 3 16.6 1.00 OFF -1.0 -100.0 -1 ? -1 -1 ONSKY NO 0  
20200207_090321 ??? 9.9 188868 14 1.03 0.10 161000 1 503 1700 382 5.6 0.6 5.6 3 17.0 1.00 OFF 58.4 -100.0 -1 H 100 1 ONSKY NO 0  
SEEING (DIMM) 1.20158 (0.174654)

WUnit Z Stage Measured Strehl
47.75 65.3
47.55 67.1
47.35 45.9
47.15 42.2
47.75 32.9
47.95 63.6
48.15 -1.0
48.35 58.4

  • focus.jpg:
    focus.jpg

  • old focus 53.25
  • IRTC focus 47.5

  • Change aoroot/calib/wfs/current/setups/LUCIFER_ACE-AO

Satelite Anik F1R

exp = 0.5 sec

H filter

offset 0, 0

  • 094839
  • 18, 094804
  • 094911
  • 19, 094910
  • 095002
  • 20, 094949

offset delta_y 0.15

  • 095217
  • 21, 095238
  • 095320
  • 22, 095318
  • 095358
  • 23, 095356

offset delta_x -0.3, delta_y 0.15

  • 095603
  • 24, 095624
  • 095705
  • 25, 095704
  • 095748
  • 26, 095747

J Filter

offset delta_x -0.3, delta_y 0.15

  • 100147
  • 27, 100145
  • 100225
  • 28, 100226
  • 100309
  • 29, 100307

offset delta_y 0.15

  • 100504
  • 30, 100502
  • 100538
  • 31, 100538
  • 100618
  • 32, 100618

offset 0 0

33, 100858 Open loop

  • 101303
  • 34, 101305
  • 101406
  • 35, 1001406
  • 101449
  • 36, 101449

Darks

J filter

  • full frame 37, 101923
  • subframe 38, 102012

H filter

  • full frame 39, 102146
  • subframe 40, 102231

PSF star

H filter

offset -0.1, -1.3

  • 105137
  • 41, 105135
  • 105231
  • 42, 105229
  • 105317
  • 43, 105317
  • optimize gain
  • 105802
  • 44, 105804
  • 105840
  • 45, 105840

offset, 0.15, -1.3

  • 110032
  • 46, 110032
  • 110110
  • 47, 110109
  • 110230
  • 48, 110159

offset, 0.15, -1.45

  • 110337
  • 49, 110341
  • 110446
  • 50, 110445
  • 110544
  • 51, 110537

J Filter

offset, 0.15, -1.6

  • 111101
  • 52, 111058
  • 111140
  • 53, 111140
  • 111220
  • 54, 111223

offset 0.15, -1.35

  • 111500
  • 55, 111456
  • 111542
  • 56, 111537
  • 111623
  • 57, 111620

offset -0.0, -1.35

  • 1118914
  • 58, 111814
  • 111902
  • 59, 111858
  • 111942
  • 60, 111939

Darks

  • J Full frame 61, 112114
  • H sub frame 62, 112335


Sat2 AnikF1

H Band

  • sub frame

offset 0.1 1.25

  • 120117
  • 63 120116
  • 120212
  • 64, 120211
  • 120247
  • 65, 120249

offset 0.3 1.25

  • 120433
  • 66, 120434
  • 120510
  • 67, 120510
  • 120546
  • 68, 120546

offset 03 1.1

  • 120706
  • 69, 120706
  • 120745
  • 70, 120743
  • 120821
  • 71, 120843

J band

  • subframe

offset 0.3 1.0

  • 1213432
  • 72, 121341
  • 121435
  • 73, 121433
  • 121522
  • 74, 121519

offset 0.3 1.3

  • 121644
  • 75, 121638
  • 121721
  • 76, 121720
  • 121803
  • 77, 121759

offset 0.1 1.2

  • 121932
  • 78, 121933
  • 122020
  • 79, 122019
  • 122059
  • 80, 122054

Darks

  • J Subframe 81, 122256
  • H Subframe 82, 122636

-- DougMiller - 07 Feb 2020
Topic revision: r4 - 11 Feb 2020, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback