20200112 SX SOUL Commissioning + ESM on sky

OSCO Data: Collect TN with subwin LUCI images

02:30 Half of SX WFS processes stop
  • perform w_stop/start
  • Looks OK but when Closed the Loop the OCAM GUI goes to Not Live
  • Tried to change binning, still not live on CL
  • Tried stopping and starting OCAM and Slope Computer processes. Still Not Live on CL
  • Warm up OCAM and will power off, stop start processes and start from scratch

03:50
  • Send OSCO Preset from LUCI
  • Bin 1 1700 Hz, 3, 100
  • subwin with TN
  • 040727, 0049 (SR 43)
  • 040942, 0050 (SR 35
  • 041109, 0051 (SR 42)
  • No NCPA, Rotator at about 230 degree, high NCPA correction needed

04:13 LUCI Dark
  • 041257, 0052

04:20 ESM + SL
  • Camera Lens pegged at 100 y
    • Rotator at 273
  • Set Intervention mode
  • Move LUCI Rot to 180 and then set preset
  • wrong reconstructor

04:53 intmatAnalyseGUI
  • 12 modes
  • intmat 20191209_200731
  • rec 20200113_045308
  • install in table_LUC...
  • Warm/stop/start wfs twice. Now OK

5 06:00 14.4 mag : 500-1000 count

06:30 15.5 : 150 - 200 counts
  • could not center camera lense at rotator 290

06:40 13.8 :