SX SOUL

We're going to do closed dome tonight, the conditions are abominable (wind, humidity)

Hexapod

3.23 3.62 -1.3 -198 -24.1

03:58
  • Doing some closed dome stuff.
  • Testing the new bin 3 reconstructor.
  • /local/aomeas/adsec_calib/M2C/KL_v20/RECs/Rec_20191215_025550.fits
  • Bin3, 120 Modes
  • Luci Dark: 20191215_034053
  • Magnitude 10.4
  • 1000 Hz
  • Disturbance:/local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Manual gain optimization: 0.30 0.20 0.20
  • 20191215_034349
Tracknum 20191215_034349
Closed Loop Yes
Is OK? No - Pyramid modulation mismatch
seeing [arcsec] 2.000000
Vwind [m/s] 14.997000
AntiDrift OFF
nphotons/sub/fr 773.097778
Magnitude 10.208750
# Modes 120
Modal rec Rec_20191215_023353.fits
Binning 3
Frequency [Hz] 1000
Modulation 3.000000
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 0.204000 0.295800
Telescope elevation 90.000000
Wind speed 0.000000
seeing from OL modes 0.815270
number of skipped framess 0
lambda [um] 1.646000
exptime [s] 1.000000
framerate [Hz] 1.000000
no. frames 10
SR SE 0.443503
LUCI dark 20191215_034053.fits_cube.fits

Tracknum 20191215_034845
Closed Loop Yes
Is OK? No - Pyramid modulation mismatch
seeing [arcsec] 2.000000
Vwind [m/s] 14.997000
AntiDrift OFF
nphotons/sub/fr 774.147034
Magnitude 10.207276
# Modes 120
Modal rec Rec_20191215_023353.fits
Binning 3
Frequency [Hz] 1000
Modulation 3.000000
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 0.204000 0.295800
Telescope elevation 90.000000
Wind speed 0.000000
seeing from OL modes 0.819076
number of skipped framess 0
lambda [um] 1.646000
exptime [s] 1.000000
framerate [Hz] 1.000000
no. frames 10
SR SE 0.474583
LUCI dark 20191215_034053.fits_cube.fits

Tracknum 20191215_035145
Closed Loop Yes
Is OK? No - Pyramid modulation mismatch
seeing [arcsec] 2.000000
Vwind [m/s] 14.997000
AntiDrift OFF
nphotons/sub/fr 774.183289
Magnitude 10.207226
# Modes 120
Modal rec Rec_20191215_023353.fits
Binning 3
Frequency [Hz] 1000
Modulation 3.000000
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 0.204000 0.295800
Telescope elevation 90.000000
Wind speed 0.000000
seeing from OL modes 0.816555
number of skipped framess 0
lambda [um] 1.646000
exptime [s] 1.000000
framerate [Hz] 1.000000
no. frames 10
SR SE 0.480311
LUCI dark 20191215_034053.fits_cube.fits

Tracknum 20191215_035336
Closed Loop Yes
Is OK? No - Pyramid modulation mismatch
seeing [arcsec] 2.000000
Vwind [m/s] 14.997000
AntiDrift OFF
nphotons/sub/fr 773.355957
Magnitude 10.208387
# Modes 120
Modal rec Rec_20191215_023353.fits
Binning 3
Frequency [Hz] 1000
Modulation 3.000000
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 0.204000 0.295800
Telescope elevation 90.000001

| Wind speed | 0.000000 |20191215_041930
seeing from OL modes 0.812958
number of skipped framess 0
lambda [um] 1.646000
exptime [s] 1.000000
framerate [Hz] 1.000000
no. frames 10
SR SE 0.462274
LUCI dark 20191215_034053.fits_cube.fits
03:5920191215_041930
  • Shutter on White Light source set to 62
  • Magnitutde 13.6
  • 10 seconds
  • Dark: 20191215_040451
  • at 1000Hz
  • 040806
  • SR in error (11.4, lol)
  • It's a little dim ~ 70 counts per subap, going to slow it down to 500Hz
  • /local/aomeas/adsec_cali20191215_041930b/CMD/disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.0000_sd3892.fits
  • Going to go with 25 second exposures, the routine keeps looking at a hot pixel.
  • Dark: 20191215_041930
Tracknum 20191215_042139
Closed Loop Yes
Is OK? No - Pyramid modulation mismatch
seeing [arcsec] 2.000000
Vwind [m/s] 14.997000
AntiDrift OFF
nphotons/sub/fr 506.837646
Magnitude 13.365116
# Modes 120
Modal rec Rec_20191215_023353.fits
Binning 3
Frequency [Hz] 500
Modulation 3.000000
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 0.204000 0.295800
Telescope elevation 90.000000
Wind speed 0.000000
seeing from OL modes 0.855102
number of skipped framess 0
lambda [um] 1.646000
exptime [s] 25.000000
framerate [Hz] 0.040000
no. frames 10
SR SE 0.268755
LUCI dark 20191215_041930.fits_cube.fits

Tracknum 20191215_043029
Closed Loop Yes
Is OK? No - Pyramid modulation mismatch
seeing [arcsec] 2.000000
Vwind [m/s] 14.997000
AntiDrift OFF
nphotons/sub/fr 506.893768
Magnitude 13.364996
# Modes 120
Modal rec Rec_20191215_023353.fits
Binning 3
Frequency [Hz] 500
Modulation 3.000000
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 0.204000 0.295800
Telescope elevation 90.000000
Wind speed 0.000000
seeing from OL modes 0.851873
number of skipped framess 0
lambda [um] 1.646000
exptime [s] 25.000000
framerate [Hz] 0.040000
no. frames 10
SR SE 0.254329
LUCI dark 20191215_041930.fits_cube.fits

Tracknum 20191215_043555
Closed Loop Yes
Is OK? No - Pyramid modulation mismatch
seeing [arcsec] 2.000000
Vwind [m/s] 14.997000
AntiDrift OFF
nphotons/sub/fr 504.765228
Magnitude 13.369565
# Modes 120
Modal rec Rec_20191215_023353.fits
Binning 3
Frequency [Hz] 500
Modulation 3.000000
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 0.204000 0.295800
Telescope elevation 90.000000
Wind speed 0.000000
seeing from OL modes 0.858341
number of skipped framess 0
lambda [um] 1.646000
exptime [s] 25.000000
framerate [Hz] 0.040000
no. frames 10
SR SE 0.266143
LUCI dark 20191215_041930.fits_cube.fits
04:42
  • Back to 1000Hz
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
-- GregoryTaylor - 15 Dec 2019