201920191212 SX SOUL Commissioning on sky

01:33 ACE
  • bin 1, 1700 Hz, 491
  • seeing 1.6"-2.1"
  • strehl = 0.35
  • some TN's have 127 Hz oscillation and LUCI image is a sausage
  • 013413 No LUCI
  • 013608 LUCI 20 image @ 0.2 (256x256) FeII
  • 013650
  • 013722
  • Dark 013921
  • 014008
  • 013413_gopt.jpg:
    013413_gopt.jpg
  • 013413_psf.jpg:
    013413_psf.jpg
  • 013413_modal.jpg: Elab modalplot does not yet include iir gain factor. auxloops plots do
    013413_modal.jpg
  • 013413_profile.jpg: (x->luci())->show_profile
    013413_profile.jpg
  • 013722_psf.jpg:
    013722_psf.jpg

01:45
  • Loop open for bad seeing >2.2"

02:23 Seeing back to 1.4"-1.9"
  • close loop on same star
  • 022355
  • 022516
  • 022559
  • 022559_modal.jpg:
    022559_modal.jpg
  • 022559_gopt.jpg:
    022559_gopt.jpg
  • 022559_jitter.jpg:
    022559_jitter.jpg

02:34
  • 023417 (luci1...19.fits)
  • 023505
  • 023536 (luci1...21.fits)
  • 023614
  • 023650

02_37 NCPA On (seeing 1.7ish)
  • 023803
  • 023835 (luci1...25.fits)
  • 023954 (luci1...26.fits)
  • 024143 (luci1...27.fits)
  • 024304
  • strehl = 0.45
  • 024304_psf.jpg:
    024304_psf.jpg

02:43 Preset
  • bin 2, 955 Hz,EMG 600
  • seeing 1.2"-1.4"
  • FeII filter. Should have more counts on LUCI
  • gopt 0.08 (scalling is not correct for bin2)
  • 025702 (luci1...32.fits)
  • 025807
  • 025904 (luci1...35.fits)
  • 030037
  • 025807

03:05 H Filter, 25000 counts
  • Strehl = 0.45
  • 030621
  • 030708
  • 030735
  • 030735_jitter.jpg:
    030037_jitter.jpg
  • 030735_gopt.jpg:
    030037_gopt.jpg
  • 030735_modal.jpg:
    030037modal.jpg
  • 030735_psf.jpg:
    030735_psf.jpg

03:09 Dark 030919 /local/aomeas

03:10 Dark 031040 Not finding this dark. take another

03:20 Dark 032012

03:21
  • 032132
  • 032242
  • 032349

03:25 NCPA On
  • 032533
  • 052626
  • 032700 (luci1...49.fits)
  • 032852

03:35 Loop closed but clouds and loop opens

03:45 Close loop
  • bin 2, 752 Hz, EMG 600
  • 14.5 mag
  • GOPT 0.06
  • Seeing 1.4"
  • 035544
  • 035654
  • 035758

03:59 Dark 040019

04:07
  • 040736
  • 040911
  • 041034
  • 041144 (loop Open)

04:25 presetAO failed on OCAM dark.
  • Send presetAO again. OK RunAO died because checkpupil routine not running. Restart
  • Preset and runao Sucess
  • bin 1, 1700 Hz, EMG 267
  • seeing 1.5"
  • 044319
  • 044354
  • 044424

04:46 Dark 044620

04:48
  • 044835
  • 044912
  • 045149

04:52 Preset to 15.1
  • bin 4, 1181 Hz, EMG 600
  • seeing 1.1"
  • GOPT 0.19
  • 050541
  • 050752
  • 051041
    • 0.07

05:12 Dark 051319

05:13
  • 051354
  • 051506
  • 051617
  • 051736 (Luci1...85.fits)
  • 052048
  • 052314
    • 0.10
  • 052525 (luci1...88.fits)
  • 052720
  • 052842

05:50 Preset to 12.5
  • bin 1, 747 Hz, EMG 600
  • GOPT 0.27
  • seeing 1.2"
  • 055444 (luci1...97.fits)
  • 055557
  • 055647
  • 055826 (luci1...100.fits)
  • 060004

06:03 Dark 060338

06:12 preset to same star
  • 062958
  • 063049
  • 063141

06:33 NCPA On
  • 063303
  • 063349
  • 063429
  • 063602
  • 063652
  • 063807 (luci images look open loop)
  • 063912 (look good again)
  • 064201

06:45 Preset to ts=16=rs= 15.9 mag
  • bin 4, 346 Hz, EMG 600
  • mag 16.1
  • edge of adsec rolls at 12:00, loop opened
  • LNGains
    • TN 072913

OSCO

07:51 Collecting TN's while OSCO script is
  • 074225, 074244, 074906, 075057
  • LUCI image 2 sec (2.51 for OSCO)
  • 080206, 080308, 080329, 080458 (1x2 sec)
  • 080548, 080648 (140), 080825, 080932 (20x2 sec)

08:12 Dark 20x2 sec 081344

08:14 Dark 1x2 sec (144, 146) 081605

09:00 Troubles with OCAM going not live

09:09 1x2.51sec Full Frame
  • 091255, 091330, 091355

09:16 1x2sec SubFrame
  • 091724, 091756, 091828

09:19 10x2sec SubFrame
  • 091900

09:29 Dark 1x2sec 092930 subwin

09:30 Dark 10x2sec 093026 Subwin

09:31 Dark 1x2.51sec 093200 Full Window

09:34 Dark 1x2sec (replace 08:14 Dark 1x2 sec (144, 146) 0816050) 093445

09:35 Dark 20x2sec (replace 08:12 Dark 20x2 sec 081344) 093704

-- DougMiller - 12 Dec 2019
I Attachment Action Size Date Who Comment
013413_gopt.jpgjpg 013413_gopt.jpg manage 27 K 12 Dec 2019 - 01:45 DougMiller  
013413_modal.jpgjpg 013413_modal.jpg manage 27 K 12 Dec 2019 - 01:56 DougMiller  
013413_profile.jpgjpg 013413_profile.jpg manage 62 K 12 Dec 2019 - 02:15 DougMiller  
013413_psf.jpgjpg 013413_psf.jpg manage 29 K 12 Dec 2019 - 01:55 DougMiller  
013722_psf.jpgjpg 013722_psf.jpg manage 32 K 12 Dec 2019 - 03:33 DougMiller  
022559_gopt.jpgjpg 022559_gopt.jpg manage 29 K 12 Dec 2019 - 03:34 DougMiller  
022559_jitter.jpgjpg 022559_jitter.jpg manage 29 K 12 Dec 2019 - 03:34 DougMiller  
022559_modal.jpgjpg 022559_modal.jpg manage 31 K 12 Dec 2019 - 03:34 DougMiller  
024304_psf.jpgjpg 024304_psf.jpg manage 30 K 12 Dec 2019 - 03:35 DougMiller  
030037_gopt.jpgjpg 030037_gopt.jpg manage 28 K 12 Dec 2019 - 03:36 DougMiller  
030037_jitter.jpgjpg 030037_jitter.jpg manage 26 K 12 Dec 2019 - 03:35 DougMiller  
030037modal.jpgjpg 030037modal.jpg manage 30 K 12 Dec 2019 - 03:36 DougMiller  
030735_psf.jpgjpg 030735_psf.jpg manage 26 K 12 Dec 2019 - 03:36 DougMiller  
Topic revision: r4 - 12 Dec 2019, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.