17:20 Finally got SX WFS powered on. Had some CCD47 startup errors. Had to stop/start CCD47 controller process and "Operate" again

18:01 Loop closed, bin 1, 12 modes

19:48 Had to change the configuration on sxadsec to use iir filters

19:48 Original "guess" TTM ao Table
# Columns:
# 0    1     2   3     4      5      6                 7                      8                9   10	   11       12       13        14      15      16      17           18       19         20     21    22   
Rmag   flux  bin freq  emGain base   rec               filtering              pupils           tt  fw1_acq fw2_acq  fw1_obs  fw2_obs   TVbin   TVfreq  TVavg   TVflux   CL->freq     emG  GOpt->mode   amp  freq  
																							                          
-1.5 1.054E9  1  1700  1       KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    3         2       0        2         4      4.3     20     1250000     200        1         30    10e-9  80.0
0.0   2.65E8  1  1700  1       KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    3         2       0        2         4      4.3     20     1250000     200        1         30    10e-9  80.0
3.5  10.54E6  1  1700  10      KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    3         2       0        2         4      4.3     20       15000     200        1         30    10e-9  80.0
4.5   4.20E6  1  1700  20      KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    4         2       0        2         4      4.3     20       15000     200        3         30    10e-9  80.0
5.5   1.67E6  1  1700  30      KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    4         2       0        2         4      4.3     20        5000     200        6         30    10e-9  80.0
6.5   6.65E5  1  1700  100     KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    4         2       0        2         4      4.3     20        2000     200       12         30    10e-9  80.0
7.5   2.65E5  1  1700  100     KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    4         2       0        2         4      4.3     20         800     200       25         30    10e-9  80.0
8.5   1.05E5  1  1700  100     KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    4         2       0        2         4      4.3     20         800     200       50         30    10e-9  80.0
9.5   4.20E4  1  1700  300     KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    4         1       0        1         4      4.3     20         800     200      100         30    10e-9  80.0
10.5  1.67E4  1  1700  600     KL_v20 20190406_035330  pureIntegratorSOUL     20181103_001410   3    4         1       0        1         4      4.3     20         800     200      300         30    10e-9  80.0
10.5  4.00e4  2  1000  300     KL_v20 20190407_034820  pureIntegratorSOUL     20181222_065045   3    4         1       0        1         4      4.3     20        1200     200      300         30    10e-9  80.0
11.5  1.50e4  2  1000  300     KL_v20 20190407_034820  pureIntegratorSOUL     20181222_065045   3    4         1       0        1         4      4.3     20        1200     200      300         30    10e-9  80.0
11.5  4.00e4  2  1000  600     KL_v20 20190407_034820  pureIntegratorSOUL     20181222_065045   3    4         1       0        1         4      4.3     20        1200     200      300         30    10e-9  80.0
12.5  1.50e4  2  1000  600     KL_v20 20190407_034820  pureIntegratorSOUL     20181222_065045   3    4         1       0        1         4      4.3     20        1200     200      300         30    10e-9  80.0
13.0    3000  2   500  600     KL_v20 20190407_034820  pureIntegratorSOUL     20181222_065045   3    4         1       0        1        16     12.6     20         300     200      600         30    15e-9  80.0
14.0    1200  2   500  600     KL_v20 20190407_034820  pureIntegratorSOUL     20181222_065045  	3    4         1       0        1        16     12.6     20         300     200      600         30    15e-9  80.0
14.0    3000  4   500  600     KL_v20 20190407_040301  pureIntegratorSOUL     20181103_004406   3    4         1       0        1        16     12.6     50         300     200      600         30    15e-9  80.0
14.5     800  4   500  600     KL_v20 20190407_040301  pureIntegratorSOUL     20181103_004406   3    4         1       0        1        16     12.6     50         300     200      600         30    15e-9  80.0
15.5     800  4   100  600     KL_v20 20190407_040301  pureIntegratorSOUL     20181103_004406   3    4         1       0        1        16     12.6     50         100     200      600         30    20e-9  80.0
16.5	 120  4   100  600     KL_v20 20190407_040301  pureIntegratorSOUL     20181103_004406   3    4         1       0        1        16     12.6     50         100     200      600         30    20e-9  80.0
17.5    26.5  4   100  600     KL_v20 20190407_040301  pureIntegratorSOUL     20181103_004406   3    4         1       0        1        16     12.6     50          10     100      600         30    25e-9  80.0
18.5    10.5  4   100  600     KL_v20 20190407_040301  pureIntegratorSOUL     20181103_004406   3    4         1       0        1        16     12.6     50          10     100      600         30    25e-9  80.0
19.5     4.2  4   100  600     KL_v20 20190407_040301  pureIntegratorSOUL     20181103_004406   3    4         1       0        1        16     12.6     50          10     100      600         30    25e-9  80.0
20.5     1.7  4   100  600     KL_v20 20190407_040301  pureIntegratorSOUL     20181103_004406   3    4         1       0        1        16     12.6     50          10     100      600         30    25e-9  80.0

Mag Lamp Binning Recon Freq EM Gain Counts/pixel photons/subap Gains
10.4 305 1 035330 200 300 200 100 -
10.4 305 1 035330 600 100 25 30 2.0 1.0 1.0
11.3 76 2 034820 530 600 300 76

21:00 Hand over to Gustavo for ARGOS work at horizon