SX NCPA Check

20:45
  • Made new bin 1 pupil: /home/AOeng/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20190909_203854
  • (I moved by an integer number of pixels)
  • makePupils.movePupils('20190530_145429',-2,0,240,2)
    makePupils_fromMasks(): moving from /home/AOeng/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt to /home/AOeng/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20190909_203854/pupdata.txt
    /bin/mv -f "/home/AOeng/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt" "/home/AOeng/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20190909_203854/pupdata.txt"
    num_slopes 2848
    len(pupi_list[0]) 1256
    out_of_pupil_slopes 336
    lines_to_add 2
    residual_pixels_to_add 24
    Entering main loop
    Out of main loop
    makePupils_common: moving fits file from /home/AOeng/aoroot/calib/wfs/current/ocam2/LUTs/mode2 to /home/AOeng/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20190909_203854

  • Everything centers nicely
20:59
  • Amali is having Chris turn a knob on the telescope...
21:14

Angle Z4 Z5 Z6 Z7 Z8 Z9 Z10 Z11
0 -20 -20 20 -10 0 0 -15 -2.7
30 -16.4 9.1 15.9 -10 -5 5 6.7 -2.6
60 -9.2 -15 10 -10 -10 -15 10 -3.6
90 0 -40 -10 -5 -10 -13.5 -15 -5.7
120 8.5 -40.3 -65 5 -10 15 -15 -7.7
150 14.4 55 -58.8 5 0 10 10 -9.6
180 15.5 75 30 20 0 -15 10 -11.6
210 12 25 80 20 10 -15 -10 -11.3
240 4.7 -40 46.9 0 0 4 -12.2 10.6
270 -4.4 -35 -15 10 15 9.6 -5 -8.6
300 -13 -4.5 -15 -5 10 -8 8 -6.2
330 -18.7 10 0 -10 5 -5.6 -7.1 -4.1
22:18
  • Unable to get IDL to work properly on the WFS
  • [AOeng@soul-sxwfs SOUL]$ aoidl
    IDL Version 7.1.1 (linux x86_64 m64). (c) 2009, ITT Visual Information Solutions
    Installation number: 223182.
    Licensed for use by: LBTO-University of Arizona

    Running the init IDL AO file...
    Setting the AO library paths...
    % Compiled module: FILEPATH.
    DLM path is : /home/AOeng/aoroot/idl/dlm:/usr/local/idl71/bin/bin.linux.x86_64
    ...user dlm paths set.
    Running the init IDL AO file...
    Setting the AO library paths...
    DLM path is : /home/AOeng/aoroot/idl/dlm:/usr/local/idl71/bin/bin.linux.x86_64
    ...user dlm paths set.
    IDL> ao_init
    % Compiled module: AO_INIT.
    % AO_INIT: WARNING: PHASEMAPDIR not initialized.
    AO> B=getaoelab('20190909_214511')
    % Compiled module: GETAOELAB.
    % AOMULTITON_ELAB::GETOBJ: Getting tracknum 20190909_214511
    % Compiled module: AOELAB__DEFINE.
    % Compiled module: AOHELP__DEFINE.
    % Compiled module: AOOVERRIDE__DEFINE.
    % Compiled module: AOMETHODHELP__DEFINE.
    % Compiled module: AOTRACKNUM__DEFINE.
    % Compiled module: AOADSEC_STATUS__DEFINE.
    % AOADSEC_STATUS::INIT: Cannot find adsec_status file:
    /local/aomeas/adsec_data/20190909/Data_20190909_214511/ads
    ec.sav. adsec_status object not available!
    % AOELAB::INIT: Warning: adsec_status object not available!
    % Compiled module: AOWFS_STATUS__DEFINE.
    % Compiled module: HEADFITS.
    % Compiled module: FXPOSIT.
    % Compiled module: MRD_HREAD.
    % Compiled module: AOGET_FITS_KEYWORD.
    % Compiled module: AOOCAM2K__DEFINE.
    % Compiled module: AOPUPILS__DEFINE.
    % Compiled module: STRSPLIT.
    % Compiled module: READFITS.
    % Compiled module: SXPAR.
    % Compiled module: GETTOK.
    % Compiled module: VALID_NUM.
    % Compiled module: READ_ASCII.
    % Compiled module: QUERY_ASCII.
    % Compiled module: UNIQ.
    % Compiled module: AOFILTW__DEFINE.
    % Compiled module: AO_GLOBAL_DATA_INIT.
    % Compiled module: AOTEL__DEFINE.
    % Compiled module: AOSANITYCHECK__DEFINE.
    % AOELAB::INIT: Warning: control object not available!
    % Compiled module: AOFRAMES_COUNTER__DEFINE.
    % Compiled module: AOVALID_PIXELS__DEFINE.
    % Compiled module: AODELAY__DEFINE.
    % AOELAB::INIT: Control info not available: Reconstructor object not
    initialized!
    % AOELAB::INIT: Control info not available: Interaction Matrix object not
    initialized!
    % AOELAB::INIT: Unknown modal basis: mode shapes not initialized...
    % Compiled module: AOMODALDISTURB__DEFINE.
    % Compiled module: AOTIME_SERIES__DEFINE.
    % Compiled module: AOWF__DEFINE.
    % Compiled module: AOSLOPES__DEFINE.
    % Compiled module: TEXTOIDL.
    % Compiled module: TEXTABLE.
    % Compiled module: STRTRANS.
    % Compiled module: TRANSLATE_SUB_SUPER.
    % Compiled module: NEXTTOK.
    % Compiled module: AOMODES__DEFINE.
    % Compiled module: STR_TOKEN.
    % Compiled module: MATCHDELIM.
    % AOMODES::INIT: WF object not available
    % Compiled module: AOCOMMANDS__DEFINE.
    % Compiled module: AOMODALCOMMANDS__DEFINE.
    % AOMODALCOMMANDS::INIT: WF object not available
    % Compiled module: AOPOSITIONS__DEFINE.
    % Compiled module: AOMODALPOSITIONS__DEFINE.
    % AOMODALPOSITIONS::INIT: WF object not available
    % Compiled module: AOOLMODES__DEFINE.
    % AOOLMODES::INIT: OLmodes cannot be reconstructed: residual modes not
    available.
    % Compiled module: AOFRAMES__DEFINE.
    % Compiled module: AOTIMESTAMPS__DEFINE.
    % Compiled module: AOTV__DEFINE.
    % Compiled module: AOPSFABSTRACT__DEFINE.
    % Compiled module: AOFRAME__DEFINE.
    % Compiled module: AOIRTC__DEFINE.
    % Compiled module: AOPISCES__DEFINE.
    % Compiled module: AOSCIENTIFICIMAGE__DEFINE.
    % Compiled module: AOLUCI__DEFINE.
    % Compiled module: AOSHARK__DEFINE.
    % Compiled module: AOOFFLOADMODES__DEFINE.
    % Compiled module: AOACCEL__DEFINE.
    % Compiled module: AOTELEMETRY__DEFINE.
    % Compiled module: JULDAY.
    AO> B->modalplot
    % Unable to invoke method on NULL object reference: <OBJREF (<NullObject>)>.
    % Execution halted at: AOELAB::MODALPLOT 726
    /home/AOeng/aoroot/idl/elab_lib/aoelab__define.pro
    % $MAIN$
    AO>
-- GregoryTaylor - 09 Sep 2019
Topic revision: r2 - 09 Sep 2019, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback