20190830 DX Collect IF data

02:21 500 modes
  • /local/aomeas/adsec_calib/flat/20190830_025059/flattening_result.sav
  • 34 nm rms
  • print, fsm_load_shape("...", force=200)
  • relax edges. looks better

02:57 400 modes
  • /local/aomeas/adsec_calib/flat/20190830_025746/flattening_result.sav
  • 33 nm rms

03:10 - 05:00 Rain delay. Telescope at horizon due to water dripping in the chamber

05:00 installed new 25 iteration FF matrix. Used the full set, not Guido's filtered version. The difference was small and want to be sure the FF matrix is good.
  • /local/aomeas/adsec_calib/ff_matrix/20190829_125817
  • put in confcalib and did a make install-conf
05:21 Noise data
  • 20190830_052100_noise_pre_1
  • 20190830_052100_noise_pre_2
05:24 IF collection, automatic amplitude. Treehouse fans were left on (unintentionally)
  • Getting a lot of hexapod drift
    /local/aomeas/adsec_calib/flat/20190830_061508/flattening_result.sav

06:18 IF collection, automatic amplitude, treehouse OFF, LUCI2 OFF, HBS on.
  • added pauses for hexalign
  • Actuator 558 jumping, removed and restarting adsec. Aborted data collection
06:37 IF collection, automatic amplitude, treehouse OFF, LUCI2 OFF, HBS on. Take 2
  • flat /local/aomeas/adsec_calib/flat/20190830_063706/flattening_result.sav
  • capturing noise frames while paused for hexalign, 20190830)064700_noise_middle

07:20 Hexalign()

07:28 Noise data
  • 20190826_072800_noise_post_1

07:30 IF Set 3. Send amplitude values

08:08 Noise data
  • 20190826_080800_noise_post_2
  • 20190826_081200_noise_post_3

TN1=['20190830_052421','20190830_052508','20190830_052557','20190830_052640','20190830_052731','20190830_052822','20190830_052913','20190830_053005','20190830_053056','20190830_053145','20190830_053233','20190830_053314','20190830_053401','20190830_053450','20190830_053539','20190830_053626','20190830_053713','20190830_053801','20190830_053849','20190830_053937','20190830_054027','20190830_054115','20190830_054203','20190830_054232','20190830_054258','20190830_054345','20190830_054434','20190830_054522','20190830_054611','20190830_054658','20190830_054745','20190830_054832','20190830_054918','20190830_055004','20190830_055050','20190830_055136','20190830_055222','20190830_055306','20190830_055351']

TN2=['20190830_063737','20190830_063837','20190830_063924','20190830_064003','20190830_064052','20190830_064142','20190830_064229','20190830_064318','20190830_064405','20190830_064453','20190830_064537','20190830_064850','20190830_064936','20190830_065022','20190830_065110','20190830_065159','20190830_065246','20190830_065334','20190830_065422','20190830_065510','20190830_065601','20190830_065748','20190830_065838','20190830_065902','20190830_065927','20190830_070016','20190830_070056','20190830_070146','20190830_070238','20190830_070328','20190830_070418','20190830_070536','20190830_070625','20190830_070714','20190830_070802','20190830_070851','20190830_070942','20190830_071032','20190830_071123']

TN3=['20190830_073506','20190830_073624','20190830_073712','20190830_073749','20190830_073840','20190830_073926','20190830_074014','20190830_074105','20190830_074151','20190830_074241','20190830_074331','20190830_074444','20190830_074534','20190830_074623','20190830_074714','20190830_074804','20190830_074852','20190830_074939','20190830_075028','20190830_075117','20190830_075206','20190830_075329','20190830_075418','20190830_075442','20190830_075505','20190830_075557','20190830_075647','20190830_075736','20190830_075824','20190830_075910','20190830_075956','20190830_080053','20190830_080141','20190830_080225','20190830_080311','20190830_080355','20190830_080439','20190830_080528','20190830_080613']

TN4=['20190830_052100_noise_pre_1','20190830_052100_noise_pre_2','20190830_064700_noise_middle']

TN5=['20190830_072800_noise_post_1','20190830_080800_noise_post_2','20190830_081200_noise_post_3']

TN6=['20190830_073506','20190830_073624','20190830_073712','20190830_064003','20190830_064052','20190830_064142','20190830_064229','20190830_064318','20190830_064405','20190830_064453','20190830_064537','20190830_064850','20190830_064936','20190830_065022','20190830_065110','20190830_065159','20190830_065246','20190830_065334','20190830_065422','20190830_065510','20190830_065601','20190830_065748','20190830_065838','20190830_065902','20190830_065927','20190830_070016','20190830_070056','20190830_070146','20190830_070238','20190830_070328','20190830_070418','20190830_070536','20190830_070625','20190830_070714','20190830_070802','20190830_070851','20190830_070942','20190830_071032','20190830_071123']