20190709 SX Soul commissioning

03:52 RunAO with repoint
  • move star on CCD47 about 3X to much
  • WFS Arbitrator
WfsArbitrator_160432|INF|      3758|2019-07-09 03:51:49.822112|             MAIN > source_acq.acquire(): starting source acquisition
WfsArbitrator_160432|INF|      3759|2019-07-09 03:51:49.823633|             MAIN > Exception: thGetVar wfsarb.L.CLICK_ACQUIRE error(-3006): Variable not found error - Assuming automatic acquisition
WfsArbitrator_160432|INF|      3760|2019-07-09 03:51:54.351135|             MAIN > Star found at x=109.5, y=84.7, flux=4532.9
WfsArbitrator_160432|INF|      3761|2019-07-09 03:51:54.352449|             MAIN > source_acq.acquire(): star found at X=437.98,Y=338.97
WfsArbitrator_160432|INF|      3762|2019-07-09 03:51:54.352512|             MAIN > source_acq.acquire(): current error X=-0.391 mm, Y=1.305 mm
WfsArbitrator_160432|DEB|      3763|2019-07-09 03:51:55.303452|             MAIN > arbFunc doCheckRef done.
  • AOS
Tue Jul 9 03:51:49.804 2019 aos.info - Computing telescope offset for AcquireRefAO
Tue Jul 9 03:51:55.304 2019 aos.info - Updated variable AOARB.L.LAB_MODE: 0
Tue Jul 9 03:51:55.304 2019 aos.info - Offset required - dx,dy: (0.391,-1.305). [(-0.05172,0.0799886) -> (0.33928,-1.22501)]
Tue Jul 9 03:51:55.317 2019 aos.info - AO loop opened
  • PCS
2019-07-09T03:51:55.338850+00:00 tcs1 LBT_PCS: PCS:UpdateReferenceOrigin executed from AOSL, handle 115997
2019-07-09T03:51:55.359743+00:00 tcs1 LBT_PCS: Setting up block for handle 115997: block:4:7
2019-07-09T03:51:55.380552+00:00 tcs1 LBT_PCS: waiting for handle block:4:7 0 115997
2019-07-09T03:51:55.517221+00:00 tcs1 LBT_PCS: Updated Ref Origin X: 0.33928 Updated Ref Origin Y: -1.22501 PCS X: 0.33909 PCS Y: -1.22431
2019-07-09T03:51:55.517242+00:00 tcs1 LBT_PCS: AOSPCS_Xi: -0.05172 AOSPCS_Eta: 0.07999
2019-07-09T03:51:57.738785+00:00 tcs1 LBT_PCS: PCS:ApplyRBTipTilt executed from PSFL, handle 115998

After the repoint (CheckRefAO) the bayside stages are moved to center the star
  • WFS Arbitrator
WfsArbitrator_160432|INF|      3767|2019-07-09 03:52:08.979508|             MAIN > Star found at x=141.5, y=191.3, flux=4179.4
WfsArbitrator_160432|INF|      3768|2019-07-09 03:52:08.981006|             MAIN > source_acq.acquire(): star found at X=566.09,Y=765.01
WfsArbitrator_160432|INF|      3769|2019-07-09 03:52:08.981072|             MAIN > source_acq.acquire(): current error X=0.610 mm, Y=-2.024 mm
WfsArbitrator_160432|INF|      3770|2019-07-09 03:52:18.992769|             MAIN > Star found at x=123.7, y=132.6, flux=4373.0
WfsArbitrator_160432|INF|      3771|2019-07-09 03:52:18.994856|             MAIN > source_acq.acquire(): star found at X=494.64,Y=530.50
WfsArbitrator_160432|INF|      3772|2019-07-09 03:52:18.994926|             MAIN > source_acq.acquire(): current error X=0.052 mm, Y=-0.191 mm
WfsArbitrator_160432|INF|      3773|2019-07-09 03:52:18.994965|             MAIN > source_acq.acquire(): target reached.
WfsArbitrator_160432|INF|      3774|2019-07-09 03:52:18.996005|             MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm

-- DougMiller - 09 Jul 2019
Topic revision: r3 - 10 Jul 2019, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback