20190701 DX 4D alignment

Alignment

10:30 Set M2 and M3 to November 2019 positions
  • see glint on 4D
  • Move M2 to see Full Pupil
  • 1100 images

11:30 Pupil it too high and left.
  • Use delta M3, M2 numbers from 20190208
  • Nicely placed in center of 4D image
  • M2 Final position:
    m2_final.jpg
  • M3 final position:
    m3_final.jpg

12:10 Hand over to Alessandro to collect pictures of 4D beams.

1:20 Collect new hexapod reconstuctor
  • /local/aomeas/adsec_calib/hexapod/20190702_202105/
  • print, hexalign(/apply)
  • 225 nm rms

1:30 can not plot on ADSEC IDL terminal
  • change elevation limit to 30 and restart
  • OK now

21:10 flatten with 200
  • /local/aomeas/adsec_calib/flat/20190702_211038/flattening_result.sav
  • 311 nm rms
  • Next flattening with 200 modes is worse. Must measure new reconstructor

21:16 print, i4d_opt_intmat(0,200)
Modal commands started, from mode 0, to mode 200
Acquiring RAW frames from 4D interferometer
         659
      -10203
4D Capturing completed
Modal commands terminated
WfsGlobalTimeout expired. Proceeding
  • 20190702_211546
  • May be too much error along outter edge. A lot of bumps

21:30 Flat with fewer modes
  • IDL> >print, fsm_load_shape("/local/aomeas/adsec_calib/flat/Applicable/default_kl_v26_90el.sav",FORCE_MAX_MODE=100)
  • flat_100m image
  • 189 nm RMS
  • Fewer bumps along outter edge

21:33 Collect new recon data 0-100
  • AdOpt> print, i4d_opt_intmat(0,100)
    • 20190702_213252
  • >>> comm4d.produce('20190702_213252') ~ 5 minutes
  • IDL> print, if_redux(/MODAL, '20190702_213252')
  • IDL> print, build_int_mat('20190702_213252')
  • AdOpt> print, opt_int_mat_reduce2(40, track='20190702_213252')
    • /local/aomeas/adsec_calib/flat/20190702_215553/flattening_result.sav
    • 117 nm rms
  • AdOpt> print, opt_int_mat_reduce2(100, track='20190702_213252')
    • /local/aomeas/adsec_calib/flat/20190702_220214/flattening_result.sav
    • 102 nm rms

21:57 101-200
  • AdOpt>print, i4d_opt_intmat(101,200)
    • 20190702_215722
  • IDL> print, if_redux(/MODAL, '20190702_215722')
  • IDL> print, build_int_mat(['20190702_213252','20190702_215722'])
  • STOP
  • Flatten above with 100 modes
  • AdOpt>print, i4d_opt_intmat(101,200)
    • 20190702_220438
  • IDL> print, if_redux(/MODAL, '20190702_220438')
  • IDL> print, build_int_mat(['20190702_213252','20190702_220438'])
  • print, opt_int_mat_reduce2(200, track='20190702_213252')
    • /local/aomeas/adsec_calib/flat/20190702_222618/flattening_result.sav
    • 56 nm rms
    • Forces when 200 modes applied:
      forces_200m.jpg

22:27 print, hexalign(/apply)

22:32 201-400
  • AdOpt>print, i4d_opt_intmat(201,400)
    • 20190702_223133
  • IDL> print, if_redux(/MODAL, '20190702_223133')
  • IDL> print, build_int_mat(['20190702_213252','20190702_220438','20190702_223133'])
  • print, opt_int_mat_reduce2(400, track='20190702_213252')
  • 300 /local/aomeas/adsec_calib/flat/20190702_231003/flattening_result.sav
  • 400 /local/aomeas/adsec_calib/flat/20190702_231412/flattening_result.sav
  • 36 nm RMS
  • 2 images flat_400m
  • Apply /local/aomeas/adsec_calib/flat/20190702_231412/flattening_result.sav
    • 634 modes
    • 42 nm RMS
    • 2 images flat_400m_apply

23:33 Hand over to Alessandro

-- DougMiller - 02 Jul 2019
I Attachment Action Size Date Who Comment
forces_200m.jpgjpg forces_200m.jpg manage 61 K 02 Jul 2019 - 22:50 DougMiller Forces when 200 modes applied
m2_final.jpgjpg m2_final.jpg manage 15 K 02 Jul 2019 - 22:47 DougMiller M2 Final position
m3_final.jpgjpg m3_final.jpg manage 18 K 02 Jul 2019 - 22:47 DougMiller M3 final position