20190612 SX 4D Flats and Tests

11:00 MST Telescope Ready for 4D tests

11:58 Full Pupil
  • align detector mask with Guido.
  • Make outer mask bigger and inner mask smaller
  • Set Modulation threshold to 19.5% so we don't fill in area without information

12:15 InterferometerCtrl -i interferometerctrl
  • failed to connect to 4D server
  • Xianyu looked and a library is not correct on SOUL version
  • Change Adsec to UAO version
  • success

1:13 print, hexalign(/apply)
  • 48 nm RMS with tip-spherical removed
  • 0.33 um of spherical probably because the barrel of the RR has moved. Not important for these tests

1:33 Power On request from AdSec Control GUI takes a long time. See idlctrl_....log below
AdSecArbitrator_26419|INF|        56|2019-06-12 20:28:18.393299|             MAIN > Received cmd: PowerOn()
AdSecArbitrator_26419|INF|        57|2019-06-12 20:28:18.393373|   COMMANDHANDLER > FSM (status: PowerOff) has received command 2004 (Power on)
idl_26302          |WAR|       190|2019-06-12 20:28:20.961437|             MAIN > [CommandSenderTimeoutException] Timeout expired
Last message repeated
idl_26302          |INF|       257|2019-06-12 20:31:38.987721|             MAIN > fsm_power_on() command started.
Last message repeated
idl_26302          |ERR|       258|2019-06-12 20:31:47.358012|      ADAM-MODBUS > [TcpReceiveException] Error receiving data (errno=4, error message means: Interrupted system call, received Bytes = 0 ), socket closed. (code -15003) TcpConnection receive error File TcpConnection.cpp line 133
idl_26302          |INF|       260|2019-06-12 20:31:56.669913|             MAIN > fsm_reset() procedure started.
idl_26302          |INF|       261|2019-06-12 20:31:56.670079|             MAIN > Disabling timeout on diagnostic frames accepted by fastdiagnostic...
idl_26302          |INF|       262|2019-06-12 20:31:56.670182|             MAIN > Ok: timeout on frames disabled.
idl_26302          |INF|       263|2019-06-12 20:31:58.818992|             MAIN > Waiting for Crate Bcus ready...
idl_26302          |INF|       264|2019-06-12 20:31:58.819068|             MAIN > Checking for BCUs 5-10 ready...
  • I think idlctrl is busy with kl=(get_z0())[0:50] command
  • Before power on, was scrolling slowly and report communication to all 6 AdSec BCUs
  • After power on the log shows at ~10 Hz the command executing

1:41 print, i4d_opt_intmat(0,200)
  • 20190612_204126
  • comm4d.produce('20190612_204126')
  • print, if_redux(/modal, '20190612_204126')
  • print, build_int_mat('20190612_204126')
  • print, opt_int_mat_reduce2(200, track='20190612_204126')
  • 57 um rms
    • two bumps on outer edge
    • go back to flat

2:31 print, i4d_opt_intmat(201, 400)
  • 20190612_213149
  • comm4d.produce('20190612_213149')
  • print, if_redux(/modal, '20190612_213149')
  • could not find trigger
  • print, i4d_opt_intmat(201, 400)
  • 20190612_220055
  • comm4d.produce('20190612_220055')
  • print, if_redux(/modal, '20190612_220055')
  • print, build_int_mat(['20190612_204126','20190612_220055'])
  • print, opt_int_mat_reduce2(400, track='20190612_204126')
  • /local/aomeas/adsec_calib/flat/20190612_224605/flattening_result.sav
  • two images
  • 60 nm RMS

3:49 default.sav
  • 55 nm RMS
  • one image

3:56 print, opt_int_mat_reduce2(300, track='20190612_204126')
  • /local/aomeas/adsec_calib/flat/20190612_225626/flattening_result.sav
  • remove spherical but get two bumps along the edge.
  • mirror force image

4:04 apply flat. Best flat but with spherical. Low foces

Will now move telescope in El
  • 90 El
    • delta 2 degrees
    • 0.0017767911 -0.069723112 0.0041501081 10.373624 0.48794086
    • delta 4 degrees
    • 0 -0.14 0 20 0 (half)
    • 0 -0.28 0 40 0 ( total)
    • hexalign() 0.012586142 0.18815328 0.013558216 -21.400788 2.7547450
    • 4D says -3.9 um, Apply 1.9 Z6
    • save file: /local/aomeas/adsec_calib/flat/20190612_84el
    • OPD: comm4d.capture(10, folder='20190612_235400_el')

4:56 Start at 84 El
  • Start -2.12 3.45 1.35 -104 -382
  • 82 el
  • hexalign: -2.11 3.38 1.35 -94.7 -381
  • 80 El
  • hexalign: -2.09 3.32 1.36 -84.7 -378.4
  • 4D: 0.9 astig X, Z4 0.4
    • save file: /local/aomeas/adsec_calib/flat/20190612_80el
    • OPD: comm4d.capture(10, folder='20190612_000600_el')
  • 4 degrees = 0.03 -0.13 0 20 3

5:09 Start at 84 El
  • -2.09 3.32 1.36 -84.7 -378.4
  • 75 el
  • delta 0.02 -0.14 0 23 2
  • 4D: 0.7, Z6 0.3
    • save file: /local/aomeas/adsec_calib/flat/20190612_75el
    • OPD: comm4d.capture(10, folder='20190612_001500_75el')
  • 70 El
  • delta 0.04 -0.12 0.01 -20 8
  • 65 El
  • delta 0.3 -0.11 0.02 15 4
  • 60 El
  • delta 0.02 -0.11 0.02 14 3
  • 4D 1.66 um, Z6 1.1
    • save file: /local/aomeas/adsec_calib/flat/20190612_60el
    • OPD: comm4d.capture(10, folder='20190612_003000_60el')

5:31 Start at 60 El
  • 55 El
  • 45 El
    • save file: /local/aomeas/adsec_calib/flat/20190612_45el
    • OPD: comm4d.capture(10, folder='20190612_004300_45el')

list1 = ['20190612_235400_el', '20190612_000600_el', '20190612_001500_75el', '20190612_003000_60el', '20190612_004300_45el']

-- DougMiller - 12 Jun 2019
  • M2 Position:
    m2.jpg

  • SX Modulation Histogram:
    sx_modulation_hist.jpg

  • SX Intensity Histogram:
    sx_intensity_hist.jpg

  • Default Flat Surface w/ Spherical Removed:
    default_surf.jpg

  • Flat w/ 400 Modes 4D:
    flatten_400m_4d.jpg

  • Flat w/ 400 Modes Surface:
    flatten_400m_surf.jpg

  • 90 El Forces:
    90el_mir.jpg

  • 75 El Forces:
    75el_mir.jpg

  • 55 El Forces (missed 60 El):
    55el_mir.jpg

  • 45 El Forces:
    45el_mir.jpg
I Attachment Action Size Date Who Comment
45el_mir.jpgjpg 45el_mir.jpg manage 87 K 13 Jun 2019 - 18:25 DougMiller 45 El Forces
55el_mir.jpgjpg 55el_mir.jpg manage 85 K 13 Jun 2019 - 18:24 DougMiller 55 El Forces (missed 60 El)
75el_mir.jpgjpg 75el_mir.jpg manage 83 K 13 Jun 2019 - 18:24 DougMiller 75 El Forces
90el_mir.jpgjpg 90el_mir.jpg manage 78 K 13 Jun 2019 - 18:24 DougMiller 90 El Forces
default_surf.jpgjpg default_surf.jpg manage 367 K 13 Jun 2019 - 18:22 DougMiller Default Flat Surface w/ Spherical Removed
flatten_400m_4d.jpgjpg flatten_400m_4d.jpg manage 298 K 13 Jun 2019 - 18:23 DougMiller Flat w/ 400 Modes 4D
flatten_400m_surf.jpgjpg flatten_400m_surf.jpg manage 409 K 13 Jun 2019 - 18:23 DougMiller Flat w/ 400 Modes Surface
m2.jpgjpg m2.jpg manage 15 K 13 Jun 2019 - 18:20 DougMiller M2 Position
sx_intensity_hist.jpgjpg sx_intensity_hist.jpg manage 692 K 13 Jun 2019 - 18:21 DougMiller SX Intensity Histogram
sx_modulation_hist.jpgjpg sx_modulation_hist.jpg manage 372 K 13 Jun 2019 - 18:21 DougMiller SX Modulation Histogram
Topic revision: r5 - 14 Jun 2019, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback