20190606 SX Soul commissioning

07:34 Reconfigured, Pointing, Collimating

08:00 ACE Preset to AO654.
  • iif_preset, AO654, mode=ACE,

08:35 Pupil re-rotator freezes because for new preset the re-rotator moved through 360 degrees, which is a not-allowed re-rotator angle. Not sure why. Arcetri will investigate
  • After power cycle the homing is taking a very long time. Homing speed seems to be very large.
  • Find that the re-rotator going through 360 degrees has left the home flag to YES. The power cycle and homing then when very slow/
  • Alfio moved the re-rotator manually so home flat was NO and then power cycled. Homing was quick and complete
  • Send new preset and runAO

08:50 Preset to AO652
  • In intervention mode, click Center Pupils. Never completes and times out after 180 seconds.
  • Alfio is now checking
  • Alfio found too many file open when he tried to tail a log file. Stopped a bunch of tail processes and tried again

09:00 Preset to AO652
  • Same problem with Center Pupil.
  • Seems AO Arbitrator is not listening to the correct WFS???

09:25 Pupil centering not working
  • Close loop manually
  • Gains 0.2, 0.05, 0.05
  • msg deamon died
  • w_stop, w_start
  • Send PresetAO to configure cameras

10:00 Closed loop manually * TN 100100 (oops, 3 second integration, Greg will set to 0 from default of 3)

10:03 Take tracking numbers
  • 30 LUCI Frames
  • 100345, 100426(no LUCI), 100547, 100623
  • LUCI Dark 100813, 101113, 101154

10:21 Closed loop at PA=90
  • 128 Hz peak lower in OVMS but still there
  • See elongated images on LUCI
  • dark 102628, 102702, 102742
  • OVMS shows no 128 Hz
  • TN 102855, 102932, 103001
  • Re_rotator was off. More TN
  • 103153, 103231, 103307

10:50 Preset and runAO
  • GOPT on, 0.43 and ratio stable at 1
  • NCPA on, Rotator at 38, Z5,6 14, 17
  • 105816, 1058512, 105927

11:02 Preset PA=180
  • Dark 111212
  • Huge 128 Hz spike in OVMS
  • 111221, 111252, 111327 (blank LUCI images)
  • No GOPT and no NCPA
  • 111500, 111532, 111615(no LUCI), 111715 (128 Hz lower by 2 orders if magnitude)
  • GOPT 0.4, NCPA On, Z5,6 = -42, -3
  • 111931, 112003, 112037
  • Oprtimize gain, No GOPT, No NCPA
  • 112355, 112432, 112456

11:25 Arcetri take over for MGM tests

-- DougMiller - 06 Jun 2019
Topic revision: r2 - 06 Jun 2019, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.