SX WFS startup

18:47
  • Waiting for telescope
19:15
  • Motion of all subsystems OK, OCAM has that weird noise and I had to cycle power.
22:22
  • We've had continual problems with the OCAM viewer going not live when the loop was closed, the "WFSFrameCounter" would increment when the loop was closed, but the OCAM would go not live.
  • We've tried numerous stops and starts of both the AdSec and the WFS. Nothing seems to have changed.
  • Xianyu found that the wrong packets are being sent from the AdSec back to the WFS.
  • The following is an excerpt from the MasterDiagnostic log on the WFS.
  • When the MasterDiagnostic process restarts after a w_stop/w_start, errors immediately begin streaming by.
  • I stopped and started the process, to see what sort of errors we were getting.
  • Here is an excerpt:
MasterDiagnostic_180674|INF| 1|2019-05-24 22:15:39.407823 MAIN > Config DisableFilottoAtBin4: 1
MasterDiagnostic_180674|INF| 2|2019-05-24 22:15:39.407879 MAIN >
MasterDiagnostic_180674|INF| 3|2019-05-24 22:15:39.407897 MAIN > ----------------------- MASTER DIAGNOSTIC GENERAL INFO ---------------------- [MasterDiagnostic.cpp:192]
MasterDiagnostic_180674|INF| 4|2019-05-24 22:15:39.407919 MAIN > > Bcu39FrameHeaderAndFooterSizeDw: 4 DWORD
MasterDiagnostic_180674|INF| 5|2019-05-24 22:15:39.407934 MAIN > > Bcu39PixelsFrameHeaderAndFooterSizeDw: 1 DWORD
MasterDiagnostic_180674|INF| 6|2019-05-24 22:15:39.407948 MAIN > > Bcu39FramePixelIntensitySizeDw: 4 DWORD
MasterDiagnostic_180674|INF| 7|2019-05-24 22:15:39.407962 MAIN > > Bcu39FrameSizeSlopesAndPixels Mode 1 (Full Frame): 22861 DWORD
MasterDiagnostic_180674|INF| 8|2019-05-24 22:15:39.407977 MAIN > > Bcu39FullFrameSizeOnlySlopesDw Mode 1 (Full Frame): 2860 DWORD
MasterDiagnostic_180674|INF| 9|2019-05-24 22:15:39.407989 MAIN > > Bcu39FullFrameSizeOnlyPixelsDW Mode 1 (Full Frame): 20002 DWORD
MasterDiagnostic_180674|INF| 10|2019-05-24 22:15:39.408003 MAIN > > Bcu39FullFrameSizeSlopesArrayDataDw Mode 1 (Full Frame): 2848 DWORD
MasterDiagnostic_180674|INF| 11|2019-05-24 22:15:39.408015 MAIN > > Bcu39FullFrameSizePixelsArrayDataDw Mode 1 (Full Frame): 20000 DWORD
MasterDiagnostic_180674|INF| 12|2019-05-24 22:15:39.408029 MAIN > > AdsecStreamFrameSize: 2030 DWORD
MasterDiagnostic_180674|INF| 13|2019-05-24 22:15:39.408056 MAIN > > BcuSwitchFrameSize: 1620 DWORD
MasterDiagnostic_180674|INF| 14|2019-05-24 22:15:39.408070 MAIN > > BcuMirrorFrameSize: 1912 DWORD
MasterDiagnostic_180674|INF| 15|2019-05-24 22:15:39.408083 MAIN > > TechViewerFrameSize: 2056 DWORD
MasterDiagnostic_180674|INF| 16|2019-05-24 22:15:39.408094 MAIN >
MasterDiagnostic_180674|INF| 17|2019-05-24 22:15:39.408107 MAIN > OPTICAL LOOP DIAGNOSTIC ENABLED: 1
MasterDiagnostic_180674|INF| 18|2019-05-24 22:15:39.408121 MAIN > > Full frame size: 24892 DWORD, 99568 Bytes (including header 1 DWORD)
MasterDiagnostic_180674|INF| 19|2019-05-24 22:15:39.408137 MAIN > > Frames history size: 0 frames (0 Bytes)
MasterDiagnostic_180674|INF| 20|2019-05-24 22:15:39.408150 MAIN > > Fil8 frames buffer capacity: 200 frames
MasterDiagnostic_180674|INF| 21|2019-05-24 22:15:39.408165 MAIN >
MasterDiagnostic_180674|INF| 22|2019-05-24 22:15:39.408179 MAIN > ADAPTIVE SECONDARY DIAGNOSTIC ENABLED: 0
MasterDiagnostic_180674|INF| 23|2019-05-24 22:15:39.408193 MAIN > > Full frame size: 13093 DWORD, 52372 Bytes (including header 1 DWORD)
MasterDiagnostic_180674|INF| 24|2019-05-24 22:15:39.408207 MAIN > > Frames history size: 1000 frames (52372000 Bytes)
MasterDiagnostic_180674|INF| 25|2019-05-24 22:15:39.408220 MAIN > > Fil8 frames buffer capacity: 8 frames
MasterDiagnostic_180674|INF| 26|2019-05-24 22:15:39.408233 MAIN >
MasterDiagnostic_180674|INF| 27|2019-05-24 22:15:39.408248 MAIN > ADAPTIVE SECONDARY BOUNCER ENABLED: 0
MasterDiagnostic_180674|INF| 28|2019-05-24 22:15:39.408261 MAIN >
MasterDiagnostic_180674|INF| 29|2019-05-24 22:15:39.408275 MAIN > TECHNICAL VIEWER ENABLED: 0
MasterDiagnostic_180674|INF| 30|2019-05-24 22:15:39.408288 MAIN >
MasterDiagnostic_180674|INF| 31|2019-05-24 22:15:39.408303 MAIN > -------------------------------------------------------------------------------
MasterDiagnostic_180674|INF| 32|2019-05-24 22:15:39.408316 MAIN >
MasterDiagnostic_180674|INF| 33|2019-05-24 22:15:39.408329 MAIN > ------------------- MASTER DIAGNOSTIC for the Optical Loop --------------------
MasterDiagnostic_180674|INF| 34|2019-05-24 22:15:39.408342 MAIN > Allocating buffer for Optical Loop diagnostic...
MasterDiagnostic_180674|INF| 35|2019-05-24 22:15:39.408367 MAIN > > Optical Loop diagnostic buffer of size 4978400 DWORD (19913600 Bytes) starting address (from header): 140207515516944, exadecimal addres:: 9b284010
MasterDiagnostic_180674|INF| 36|2019-05-24 22:15:39.421112 MAIN > Allocating buffer status table with capacity 200...
MasterDiagnostic_180674|INF| 37|2019-05-24 22:15:39.421609 MAIN > -------------------------------------------------------------------------------
MasterDiagnostic_180674|INF| 38|2019-05-24 22:15:39.421634 MAIN >
MasterDiagnostic_180674|INF| 39|2019-05-24 22:15:39.421645 MAIN > Setting optical loop (1 = CLOSE loop, 0 = OPEN loop)...
MasterDiagnostic_180674|INF| 40|2019-05-24 22:15:39.421712 MAIN > Optical loop set to 0 ...
MasterDiagnostic_180674|INF| 41|2019-05-24 22:15:39.421744 MAIN > Installing dump-history handlers...
MasterDiagnostic_180674|INF| 42|2019-05-24 22:15:39.422065 MAIN > Starting thrdlib. Server is @ 127.0.0.1
MasterDiagnostic_180674|INF| 43|2019-05-24 22:15:39.430391 MAIN > Open/Close optical-loop RTDB vars support installed...
MasterDiagnostic_180674|INF| 44|2019-05-24 22:15:39.431274 MAIN >
MasterDiagnostic_180674|INF| 45|2019-05-24 22:15:39.431304 MAIN > ------------------- STARTING MASTER DIAGNOSTIC SYSTEM --------------------
MasterDiagnostic_180674|WAR| 46|2019-05-24 22:15:39.431354 MAIN > Real-time priority not set !
MasterDiagnostic_180674|INF| 47|2019-05-24 22:15:39.431369 MAIN > > STARTING OPTICAL LOOP DIAGNOSTIC...
MasterDiagnostic_180674|INF| 48|2019-05-24 22:15:39.431423 MAIN > > STARTING BCU39 FRAME DOWNLOADER...
MasterDiagnostic_180674|INF| 49|2019-05-24 22:15:39.432169 MAIN > > STARTING ADSEC STREAM FRAME DOWNLOADER...
MasterDiagnostic_180674|WAR| 50|2019-05-24 22:15:39.432234 MAIN > Real-time priority not set !
MasterDiagnostic_180674|WAR| 51|2019-05-24 22:15:39.432329 MAIN > Real-time priority not set !
MasterDiagnostic_180674|WAR| 52|2019-05-24 22:15:39.432490 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 329 (instead of packetId 3 for frameId 328)
MasterDiagnostic_180674|WAR| 53|2019-05-24 22:15:39.432513 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 54|2019-05-24 22:15:39.432568 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 329 (instead of packetId 0 for frameId 329)
MasterDiagnostic_180674|WAR| 55|2019-05-24 22:15:39.432586 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 56|2019-05-24 22:15:39.432626 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 329 (instead of packetId 0 for frameId 329)
MasterDiagnostic_180674|WAR| 57|2019-05-24 22:15:39.432642 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 58|2019-05-24 22:15:39.432705 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 331 (instead of packetId 3 for frameId 330)
MasterDiagnostic_180674|WAR| 59|2019-05-24 22:15:39.432721 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 60|2019-05-24 22:15:39.432763 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 331 (instead of packetId 0 for frameId 331)
MasterDiagnostic_180674|WAR| 61|2019-05-24 22:15:39.432779 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 62|2019-05-24 22:15:39.432814 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 331 (instead of packetId 0 for frameId 331)
MasterDiagnostic_180674|WAR| 63|2019-05-24 22:15:39.432832 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 64|2019-05-24 22:15:39.432906 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 333 (instead of packetId 3 for frameId 332)
MasterDiagnostic_180674|WAR| 65|2019-05-24 22:15:39.432923 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 66|2019-05-24 22:15:39.432962 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 333 (instead of packetId 0 for frameId 333)
MasterDiagnostic_180674|WAR| 67|2019-05-24 22:15:39.432978 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 68|2019-05-24 22:15:39.433016 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 333 (instead of packetId 0 for frameId 333)
MasterDiagnostic_180674|WAR| 69|2019-05-24 22:15:39.433031 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 70|2019-05-24 22:15:39.435778 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 335 (instead of packetId 3 for frameId 334)
MasterDiagnostic_180674|WAR| 71|2019-05-24 22:15:39.435841 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 72|2019-05-24 22:15:39.435883 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 335 (instead of packetId 0 for frameId 335)
MasterDiagnostic_180674|WAR| 73|2019-05-24 22:15:39.435894 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 74|2019-05-24 22:15:39.435920 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 335 (instead of packetId 0 for frameId 335)
MasterDiagnostic_180674|WAR| 75|2019-05-24 22:15:39.435931 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 76|2019-05-24 22:15:39.439726 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 337 (instead of packetId 3 for frameId 336)
MasterDiagnostic_180674|WAR| 77|2019-05-24 22:15:39.439751 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !
MasterDiagnostic_180674|WAR| 78|2019-05-24 22:15:39.439796 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 337 (instead of packetId 0 for frameId 337)
MasterDiagnostic_180674|WAR| 79|2019-05-24 22:15:39.439824 ADSEC_STREAM > FramesDownloader ADSEC_STREAM: packet successfully ignored !

-- GregoryTaylor - 24 May 2019
Topic revision: r2 - 24 May 2019, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback