20190430_SX_Day SX SOUL High Resolution NCPA table

Startup system

  • Put SX AdSec in SOUL mode
  • Power on SOUL wfs
  • Chill OCAM
  • Close Loop with AOS Command GUI (to get disturbance file name)
    • NOTE: the TT mirror seems to have a problem. Two pupils are bright and two are dim
  • CmdDisturb _201904230_182307.fits
  • Had to power off/on WFS. Warmed first

System runnihg with GOPT and NCPA

  • move to 360 degrees
  • Waiting for tour, lights on

Collect data

21:23 LUCI Dark 04
  • 212514
  • RETROREF -> ncpa.mar.2019.dat
  • LUCIFER -> LUCIFER_20190313
TN NCPA ON NCPA OFF NCPA Coeff
360 213146 05 213235 06  
330 213735 07 213818 08 213849 09  
300 220340 (long exp) 10 220507 11 220541n 12  
290 222228 17 222330 18 -10.1 -14.7 -15.0 0 11.6 -2.1 3.7 -6.7
280 221800 15 221856 16 -7.2 -24.8 -15.0 5.0 13.2 3.7 -0.7 -7.5
270 220922 13 221011 14  
260 222642 19 222800 20 -1.3 -36.7 5.6 6.6 9.9 7.7 -7.4 -2.1
250 223612 21 223705 22 1.6 -38.3, 26.3 3.3 5.0 5.9 -9.8 4
240 223959 23   4.6 -40 46.9 0 0 4 -12.2 10.1
230 224414 24   7.1, -18.3 57.9 6.6 3.3 -2.3 -11.4 3.2
220 225003 25 225135 26 9.6 3.3 69 13.2 6.6 -8.6 -10.7
210 225358 27 225525 28 12.2 25 80 19.8 9.9 -15.0 -10 -10.7
Thresholded NCPA RETROREF -> LUCIFER_20190313_thresholded LUCIFER -> LUCIFER_20190313_thresholded
210 232338 29 232528 30   12.2 -16.7 53.3 19.8 9.9 -15 -10 -10.7
240 233529 31 233717 33 4.6 -40 46.98 0 0 4 -12.2 10.1
210 234350 36 Thresh  
210 234248 35 Full  
180 235051 37 Thresh  

23:52 d Lost Fastlink commincation to SX AdSEc. OCAM freeze.
  • Tried to Change OCAM rate from 1700 to 1000 and got a slopecomputer tineout error at 23:56
  • Warming up OCAM, will stop for today

  • hexapod position 2.69 1.93 -0.78 -68 -242

Analysis 20190502 DLM

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq emGain gain mod rot angle NCPA SR filter exp #frames disturb SN skip notes
20190430_213146 ??? 10.3 323998 8 NaN 0.02 201757 1 501 1700 600 0.32 0.13 0.06 3 360 On Full 84.0 clear H 157 20 ONSKY NO 0 - Could not test SR quality
20190430_213235 ??? 10.3 323998 10 NaN 0.02 201757 1 501 1700 600 0.32 0.13 0.06 3 360 Off 90.1 clear H 157 20 ONSKY NO 0 - Could not test SR quality
20190430_213745 ??? 10.3 323998 6 NaN 0.03 201757 1 501 1700 600 0.22 0.13 0.07 3 330 On Full 72.4 clear H 157 20 ONSKY NO 0  
20190430_220507 ??? 10.4 323998 4 NaN 0.13 201757 1 501 1700 600 0.25 0.13 -1.00 3 300 On Full 79.1 clear H 157 20 ONSKY NO 0  
20190430_220541 ??? 10.4 323998 2 NaN 0.13 201757 1 501 1700 600 0.25 0.13 -1.00 3 300 Off 69.4 clear H 157 20 ONSKY NO 0  
20190430_220922 ??? 10.4 323998 6 NaN 0.12 201757 1 501 1700 600 0.20 0.10 -1.00 3 270 On Full 79.0 clear H 157 20 ONSKY NO 0  
20190430_221011 ??? 10.4 323998 8 NaN 0.12 201757 1 501 1700 600 0.20 0.10 -1.00 3 270 Off 61.0 clear H 157 20 ONSKY NO 0  
20190430_221800 ??? 10.4 323998 7 NaN 0.13 201757 1 501 1700 600 0.20 0.10 -1.00 3 280 On Full 78.2 clear H 157 20 ONSKY NO 0  
20190430_221856 ??? 10.4 323998 6 NaN 0.13 201757 1 501 1700 600 0.20 0.10 -1.00 3 280 Off 71.0 clear H 157 20 ONSKY NO 0  
20190430_222228 ??? 10.4 323998 7 NaN 0.13 201757 1 501 1700 600 0.20 0.10 -1.00 3 290 On Full 72.4 clear H 157 20 ONSKY NO 0  
20190430_222330 ??? 10.4 323998 8 NaN 0.12 201757 1 501 1700 600 0.20 0.10 -1.00 3 290 Off 68.9 clear H 157 20 ONSKY NO 0  
20190430_222642 ??? 10.4 323998 5 NaN 0.13 201757 1 501 1700 600 0.20 0.10 -1.00 3 260 On Full 69.1 clear H 157 20 ONSKY NO 0  
20190430_222800 ??? 10.4 323998 4 NaN 0.13 201757 1 501 1700 600 0.20 0.10 -1.00 3 260 Off 59.0 clear H 157 20 ONSKY NO 0  
20190430_223612 ??? 10.4 323998 4 NaN 0.02 201757 1 501 1700 600 0.19 0.12 0.09 3 250 On Full 75.6 clear H 157 20 ONSKY NO 0  
20190430_223705 ??? 10.4 323998 3 NaN 0.02 201757 1 501 1700 600 0.19 0.12 0.09 3 250 Off 58.1 clear H 157 20 ONSKY NO 0  
20190430_223959 ??? 10.4 323998 3 NaN 0.02 201757 1 501 1700 600 0.20 0.10 -1.00 3 240 On Full 78.5 clear H 157 20 ONSKY NO 0  
20190430_224414 ??? 10.4 323998 5 NaN 0.02 201757 1 501 1700 600 0.20 0.10 -1.00 3 230 On Full 69.1 clear H 157 20 ONSKY NO 0  
20190430_225003 ??? 10.4 323998 10 NaN 0.02 201757 1 501 1700 600 0.20 0.10 -1.00 3 220 Edge On Full 0.0 clear H 157 20 ONSKY NO 0  
20190430_225145 ??? 10.4 323998 8 NaN 0.02 201757 1 501 1700 600 0.20 0.10 -1.00 3 220 Edge Off 0.0 clear H 157 20 ONSKY NO 0  
20190430_225358 ??? 10.4 323998 6 NaN 0.02 201757 1 501 1700 600 0.20 0.10 -1.00 3 210 Edge Off 148.9 clear H 157 20 ONSKY NO 0  
20190430_225525 ??? 10.4 323998 9 NaN 0.02 201757 1 501 1700 600 0.20 0.10 -1.00 3 210 Edge On Full 0.0 clear H 157 20 ONSKY NO 0  
20190430_232338 ??? 10.4 323998 6 NaN 0.05 201757 1 501 1700 600 0.25 0.06 -1.00 3 210 Edge On Thresh 175.0 clear H 3000 20 ONSKY NO 0  
20190430_232528 ??? 10.4 323998 1 NaN 0.06 201757 1 501 1700 600 0.25 0.06 -1.00 3 210 Edge On Thresh 165.7 clear H 157 20 ONSKY NO 0  
20190430_233529 ??? 10.4 323998 10 NaN 0.05 201757 1 501 1700 600 0.20 0.13 0.13 3 240 On Full 79.1 clear H 157 20 ONSKY NO 0  
20190430_233648 ??? 10.4 323998 9 NaN 0.05 201757 1 501 1700 600 0.20 0.13 0.13 3 240 On Thresh 69.8 clear H 157 20 ONSKY NO 0  
20190430_233717 ??? 10.4 323998 8 NaN 0.06 201757 1 501 1700 600 0.20 0.13 0.13 3 240 Off 55.3 clear H 157 20 ONSKY NO 0  
20190430_234248 ??? 10.4 323998 10 NaN 0.05 201757 1 501 1700 600 0.20 0.10 -1.00 3 210 On Full 72.4 clear H 157 20 ONSKY NO 0  
20190430_234353 ??? 10.4 323998 10 NaN 0.05 201757 1 501 1700 600 0.20 0.10 -1.00 3 210 Off 54.4 clear H 157 20 ONSKY NO 0  
20190430_235051 ??? 10.4 323998 7 NaN 0.02 201757 1 501 1700 600 0.25 0.06 0.13 3 180 On Thresh 67.0 clear H 157 20 ONSKY NO 0  
['20190430_213146','20190430_213235','20190430_213745','20190430_213818','20190430_213849','20190430_220340','20190430_220507','20190430_220541','20190430_220922','20190430_221011','20190430_221800','20190430_221856','20190430_222228','20190430_222330','20190430_222642','20190430_222800','20190430_223612','20190430_223705','20190430_223959','20190430_224414','20190430_225003','20190430_225145','20190430_225358','20190430_225525','20190430_232338','20190430_232528','20190430_233529','20190430_233648','20190430_233717','20190430_234248','20190430_234353','20190430_235051']

  • Strehl -vs- Rotator Angle:
    strehl-v-rot.jpg
  • Interpolated NCPA Coefficients:
    Inter_ncpa.jpg

* Rotator 210, Full NCPA, Rotator 180, Thresholded NCPA, Rotator 210, NCPA Off
234248.jpg 235051.jpg 234353.jpg

-- DougMiller - 30 Apr 2019
I Attachment Action Size Date Who Comment
234248.jpgjpg 234248.jpg manage 239 K 16 May 2019 - 19:59 DougMiller Rotator 210, Full NCPA
234353.jpgjpg 234353.jpg manage 242 K 16 May 2019 - 19:51 DougMiller Rotator 210, NCPA Off
235051.jpgjpg 235051.jpg manage 212 K 16 May 2019 - 19:52 DougMiller Rotator 180, Thresholded NCPA
Inter_ncpa.jpgjpg Inter_ncpa.jpg manage 135 K 16 May 2019 - 21:50 DougMiller Interpolated NCPA Coefficients
strehl-v-rot.jpgjpg strehl-v-rot.jpg manage 148 K 16 May 2019 - 19:42 DougMiller Strehl -vs- Rotator Angle
Topic revision: r5 - 16 May 2019, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback