201904305_SX_Night SX SOUL Commissioning

Presets

  • 8.5 mag
  • 11.2
  • 12.4

06:30 12.4 mag presetAO Failed
  • PresetAO {FLAO}[20] - [AOException] presetAO: FATAL - Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
  • OCAM go "not live" to reconfigure to bin 2 from bin 1 and never go live.

07:29 PresetAO failed
  • PresetAO{FLAO}[32] - [AOException] presetAO: FATAL - [Errno 4] Interrupted system call
  • sent the presetAO again
  • moved the correct direction but my factor of 2 too much
2019-04-06T07:40:37.781364+00:00 tcs1 LBT_AOSL: AOSL:AcquireRefAO executed from AOSGUI, handle 43
2019-04-06T07:40:37.794779+00:00 tcs1 LBT_AOSL: [I] AcquireRef{FLAO}[43] Mode: Repoint telescope, Automatic acquire
2019-04-06T07:40:37.811339+00:00 tcs1 LBT_AOSL: [I] Computing telescope offset for AcquireRefAO
2019-04-06T07:40:38.053642+00:00 tcs1 LBT_PCS: PCS:ComputeKFPCoordinates executed from GCSL, handle 1993
2019-04-06T07:40:38.068120+00:00 tcs1 LBT_PCS: PCS. computeKFPCoordinates.  SIDEREAL. Sender: GCSL
2019-04-06T07:40:38.134248+00:00 tcs1 LBT_PCS: Setting up block for handle 1993: block:6:7
2019-04-06T07:40:38.170897+00:00 tcs1 LBT_PCS: waiting for handle block:6:7 0 1993
2019-04-06T07:40:39.385175+00:00 tcs1 LBT_AOSL: [I] Updated variable AOARB.L.LAB_MODE:  0
2019-04-06T07:40:39.399069+00:00 tcs1 LBT_AOSL: [I] Offset required - dx,dy: (0.544,-1.583). [(-0.14011,0.104071) -> (0.403891,-1.47893)]
2019-04-06T07:40:39.408566+00:00 tcs1 LBT_PCS: PCS:UpdateReferenceOrigin executed from AOSL, handle 1994
2019-04-06T07:40:39.412671+00:00 tcs1 LBT_AOSL: [I] AO loop opened
2019-04-06T07:40:39.438894+00:00 tcs1 LBT_PCS: Setting up block for handle 1994: block:7:7
2019-04-06T07:40:39.441739+00:00 tcs1 LBT_AOSL: [I] Updated variable AOARB.L.SL_READY:  1
2019-04-06T07:40:39.469742+00:00 tcs1 LBT_AOSL: [I] Updated variable AOARB.L.AO_READY:  1
2019-04-06T07:40:39.475396+00:00 tcs1 LBT_PCS: waiting for handle block:7:7 0 1994
2019-04-06T07:40:39.590291+00:00 tcs1 LBT_PCS: Updated Ref Origin X: 0.40389049053192 Updated Ref Origin Y: -1.47892856597900 PCS X: 0.40380569224114 PCS Y: -1.47861805949884
2019-04-06T07:40:39.590312+00:00 tcs1 LBT_PCS: AOSPCS_Xi: -0.14010952574205 AOSPCS_Eta: 0.10407143338164
2019-04-06T07:40:39.751115+00:00 tcs1 LBT_PCS: PCS:ApplyRBTipTilt executed from PSFL, handle 1995
2019-04-06T07:40:39.751334+00:00 tcs1 LBT_PCS: PCS:ApplyRBTipTilt execution time: 0 ms from PSFL, handle 1995
2019-04-06T07:40:39.771515+00:00 tcs1 LBT_PSFL: PSFL:adjustPointing execution time: 2752 ms from PCS, handle 4443
2019-04-06T07:40:40.064893+00:00 tcs1 LBT_PCS:      Guider.  left timeSSE: 1554536440.06487202644348 deltaS: 4.95637297630310 mjdutcs: 5061253240.06200027465820
2019-04-06T07:40:40.064931+00:00 tcs1 LBT_PCS: Guider. Time (MJDTAI): 58579.32033636574488 mjdutcs: 5061253240.06200027465820 gxpos (mm): 59.66054910392722 gypos (mm): 39.54443382975951 gxvel (arcs/hr): -0.12857623372868 gyvel (arcs/hr): 0.03531421453013
2019-04-06T07:40:40.064947+00:00 tcs1 LBT_PCS: Guider. left GCS - Initial Xi("): 99.72707975426452 Eta("): 66.10148524627085 Ximm: 59.67307765745544 Etamm: 39.55273805362974
2019-04-06T07:40:40.065015+00:00 tcs1 LBT_PCS: GCS/computeKFPCoordinates. left RADEC 11:17:37.232 +17:16:04.70 AGw_Wave: 0.62999999523163 appMag: 12.07000000000000 WaveBandOfMag: R
2019-04-06T07:40:40.065026+00:00 tcs1 LBT_PCS: GCS/computeKFPCoordinates. left GCS: Proper Motion RA(mas/yr): 4.00000000000383 Proper Motion Dec(mas/yr): -14.00000000001340
2019-04-06T07:40:40.065039+00:00 tcs1 LBT_PCS: GCS/computeKFPCoordinates. left PM CorrRA: 11:17:37.237 PM CorrDec: +17:16:04.43
2019-04-06T07:40:40.096080+00:00 tcs1 LBT_PCS: PCS:ComputeKFPCoordinates execution time: 2043 ms from GCSL, handle 1993
2019-04-06T07:40:40.096111+00:00 tcs1 LBT_PCS: wait done for handle block:6:7 0 1993
2019-04-06T07:40:40.128740+00:00 tcs1 LBT_GCSL: GT: calcGuideCorr: GHS 250.66 256.12[pix]  59.673 39.553[mm], corrected pos to PCS 241.41 248.98[pix] 59.373 39.321[mm]  gs2hs_dxy 9.247 7.142 gs2hs 0.380 gs2hs(arcs) 0.633 GHS(mm)
2019-04-06T07:40:40.132294+00:00 tcs1 LBT_GCSL: GT: execute: GuideRate Hz eff/max 0.202 : 0.202 Hz, exp: 2.100 PCSxfer: 0.000 imAcq: 2.757 Prb: 0.000 overhead: 2.202 total: 4.960
2019-04-06T07:40:41.255485+00:00 tcs1 LBT_PCS: TimeToLimit tai 58579.32035006 encoderAz 247.14780 encoderEl 58.92002 encoderRot[SX] 125.73861 encoderRot[DX] 386.56064 limitAz 2147483647 limitEl 8391 limit Rot SX 2147483647 DX 2147483647
2019-04-06T07:40:42.129181+00:00 tcs1 LBT_PSFL: PSFL:adjustPointing executed from PCS, handle 4446
2019-04-06T07:40:43.010523+00:00 tcs1 LBT_PCS: PCS:ComputeKFPCoordinates executed from GCSL, handle 1996
2019-04-06T07:40:43.020850+00:00 tcs1 LBT_PCS: PCS. computeKFPCoordinates.  SIDEREAL. Sender: GCSL
2019-04-06T07:40:43.091716+00:00 tcs1 LBT_PCS: Setting up block for handle 1996: block:8:7
2019-04-06T07:40:43.112566+00:00 tcs1 LBT_PCS: waiting for handle block:8:7 0 1996
2019-04-06T07:40:44.823390+00:00 tcs1 LBT_PCS: PCS:ApplyRBTipTilt executed from PSFL, handle 1997
2019-04-06T07:40:44.823583+00:00 tcs1 LBT_PCS: PCS:ApplyRBTipTilt execution time: 0 ms from PSFL, handle 1997
2019-04-06T07:40:44.843872+00:00 tcs1 LBT_PSFL: PSFL:adjustPointing execution time: 2714 ms from PCS, handle 4446
2019-04-06T07:40:44.867862+00:00 tcs1 LBT_PCS: PCS:UpdateReferenceOrigin execution time: 5459 ms from AOSL, handle 1994
2019-04-06T07:40:44.867898+00:00 tcs1 LBT_PCS: wait done for handle block:7:7 0 1994
  • IT#

-- DougMiller - 06 Apr 2019
Topic revision: r2 - 07 Apr 2019, DougMiller